Wyniki wyszukiwania dla: BREATH ANALYSIS - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: BREATH ANALYSIS

Wyniki wyszukiwania dla: BREATH ANALYSIS

  • Modeling of Cardiac Component of Subarachnoid Space Changes in Apnoea Resulting as a Function of Blood Pressure and Blood Flow Parameters - Two Mechanizm of Regulation

    Publikacja

    - Rok 2017

    Experiments were performed in a group of 19 healthy, non-smoking volunteers. The experiment consisted of three apnoeas, sequentially: 30 s apnoea, 60 s apnoea and maximal, that could be done, apnoea. The breath-hold was separated for 5 minutes rest. The following parameters were measured and obtained for further analysis: blood parameters, artery diameter of the internal carotid artery, end-tidal CO2 in expired air, the cardiac...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Embedded gas sensing setup for air samples analysis

    This paper describes a measurement setup (eNose) designed to analyze air samples containing various volatile organic compounds (VOCs). The setup utilizes a set of resistive gas sensors of divergent gas selectivity and sensitivity. Some of the applied sensors are commercially available and were proposed recently to reduce their consumed energy. The sensors detect various VOCs at sensitivities determined by metal oxide sensors’ technology...

    Pełny tekst do pobrania w portalu

  • Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency

    Publikacja
    • P. J. Winklewski
    • M. Gruszecki
    • J. Wolf
    • E. Świerblewska
    • K. Kunicka
    • M. Wszędybył-Winklewska
    • W. Gumiński
    • J. Zabulewicz
    • A. F. Frydrychowski
    • L. Bieniaszewski... i 2 innych

    - MICROVASCULAR RESEARCH - Rok 2015

    Pial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Volatile Compound Emissions from Stereolithography Three-Dimensional Printed Cured Resin Models for Biomedical Applications

    Publikacja

    - CHEMICAL RESEARCH IN TOXICOLOGY - Rok 2023

    Stereolithography three-dimensional printing is used increasingly in biomedical applications to create components for use in healthcare and therapy. The exposure of patients to volatile organic compounds (VOCs) emitted from cured resins represents an element of concern in such applications. Here, we investigate the biocompatibility in relation to inhalation exposure of volatile emissions of three different cured commercial resins...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Emotion Monitor - Concept, Construction and Lessons Learned

    This paper concerns the design and physical construction of an emotion monitor stand for tracking human emotions in Human-Computer Interaction using multi-modal approach. The concept of the stand using cameras, behavioral analysis tools and a set of physiological sensors such as galvanic skin response, blood-volume pulse, temperature, breath and electromyography is presented and followed...

    Pełny tekst do pobrania w portalu

  • Modelling of subarachnoid space width changes in apnoea resulting as a function of blood flow parameters

    Publikacja

    - MICROVASCULAR RESEARCH - Rok 2017

    During apnoea, the pial artery is subjected to two opposite physiological processes: vasoconstriction due to elevated blood pressure and vasorelaxation driven by rising pH in the brain parenchyma. We hypothesized that the pial artery response to apnoea may vary, depending on which process dominate. Apnoea experiments were performed in a group of 19 healthy, non-smoking volunteers (9 men and 10 women). The following parameters...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Non-Gaussian Resistance Fluctuations in Gold-Nanoparticle-Based Gas Sensors: An Appraisal of Different Evaluation Techniques

    Publikacja

    - SENSORS - Rok 2017

    Volatile organic compounds, such as formaldehyde, can be used as biomarkers in human exhaled breath in order to non-invasively detect various diseases, and the same compounds are of much interest also in the context of environmental monitoring and protection. Here, we report on a recently-developed gas sensor, based on surface-functionalized gold nanoparticles, which is able to generate voltage noise with a distinctly non-Gaussian...

    Pełny tekst do pobrania w portalu

  • Olfactory receptor-based biosensors as potential future tools in medical diagnosis

    Publikacja

    - TRAC-TRENDS IN ANALYTICAL CHEMISTRY - Rok 2022

    The detection of biomarkers is the future of non-invasive medical diagnosis and screening. Discovery and identification of reliable disease specific volatile organic compounds is dependent on repeatable, accurate analysis of trace level gaseous analytes mainly in breath samples. Natural variety of the olfactory systems and the compounds capable of gas molecules binding creates wide possibilities of acquisition and implementation...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A body position influence on ECG derived respiration

    An influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Jacek Namieśnik prof. dr hab. inż.

    Osoby

    Urodził się 10 grudnia 1949 r. w Mogilnie, zmarł 14 kwietnia 2019 r. w Gdańsku – polski chemik, profesor nauk chemicznych, specjalizujący się w chemii analitycznej i środowiskowej. Rektor Politechniki Gdańskiej w latach 2016–2019. Studia wyższe ukończył w 1972 r. na Wydziale Chemicznym Politechniki Gdańskiej, uzyskując tytuł magistra inżyniera chemika. W 1972 r. rozpoczął pracę na Politechnice Gdańskiej, gdzie w 1978 r. obronił...

  • Driver’s Condition Detection System Using Multimodal Imaging and Machine Learning Algorithms

    To this day, driver fatigue remains one of the most significant causes of road accidents. In this paper, a novel way of detecting and monitoring a driver’s physical state has been proposed. The goal of the system was to make use of multimodal imaging from RGB and thermal cameras working simultaneously to monitor the driver’s current condition. A custom dataset was created consisting of thermal and RGB video samples. Acquired data...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The occurence and diagnosis of biomarkers of ethyl alcohol consumption

    Publikacja

    - UWM Law Review - Rok 2015

    Ethyl alcohol is a legal and a widely available psychoactive drug. However, its excessive consumption causes addiction. This leads to aggressive behaviors, family battery, difficulties in interpersonal relations, legal offences, suicides, car accidents and deterioration in labor productivity, what causes financial problems. Despite many social actions against alcohol consumption, this problem is still unresolved. Therefore, fast...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Machine Learning and Electronic Noses for Medical Diagnostics

    Publikacja

    The need for noninvasive, easy-to-use, and inexpensive methods for point-of-care diagnostics of a variety of ailments motivates researchers to develop methods for analyzing complex biological samples, in particular human breath, that could aid in screening and early diagnosis. There are hopes that electronic noses, that is, devices based on arrays of semiselective or nonselective chemical sensors, can fill this niche. Electronic...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Fully Automated AI-powered Contactless Cough Detection based on Pixel Value Dynamics Occurring within Facial Regions

    Publikacja

    - Rok 2021

    Increased interest in non-contact evaluation of the health state has led to higher expectations for delivering automated and reliable solutions that can be conveniently used during daily activities. Although some solutions for cough detection exist, they suffer from a series of limitations. Some of them rely on gesture or body pose recognition, which might not be possible in cases of occlusions, closer camera distances or impediments...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Pial artery and subarachnoid width response to apnoea in normal humans

    Publikacja
    • M. Wszędybył-Winklewska
    • J. Wolf
    • E. Świerblewska
    • K. Kunicka
    • M. Gruszecki
    • W. Gumiński
    • P. J. Winklewski
    • A. F. Frydrychowski
    • L. Bieniaszewski
    • K. Narkiewicz
    • K. Narkiewicz

    - JOURNAL OF HYPERTENSION - Rok 2015

    Background: Little is known about intracranial pressure (ICP)-cerebral haemodynamic interplay during repetitive apnoea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Method: We tested the complex response of the pial artery and subarachnoid width to apnoea...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Electronic Noses in Medical Diagnostics

    Electronic nose technology is being developed in order to identify aromas in a way parallel to the biologic olfaction. When applied to the field of medicine, such device should be able to identify and discriminate between different diseases. In recent years this kind of approach finds application in medical diagnostics, and especially in disease screening. Despite the fact that devices utilizing chemical sensor arrays are not routinely...

    Pełny tekst do pobrania w serwisie zewnętrznym