Wyniki wyszukiwania dla: FULL-SCALE WASTEWATER TREATMENT PLANT
-
The hybrid estimation algorithm for wastewater treatment plant robust model predictive control purposes at medium time scale
PublikacjaThe paper proposes an approach to designing the hybrid estimation algorithm/module (HEA) with moving measurements window for Wastewater Treatment Plant (WWTP) Robust Model Predictive Control (RMPC) purposes at medium time scale. The RMPC uses a dedicated grey-box model of biological reactor for the system outputs prediction purposes. The grey-box model parameters are dependant on the plant operating point. Hence, these parameters...
-
Estimation of wastewater treatment plant state for model predictive control of N-P remowal at medium time scale.
PublikacjaPrzy ograniczonych możliwościach pomiarowych estymaty stanu są potrzebne w sterowaniu optymalizującym, opartym na sterowaniu predykcyjnym, sterującym usuwaniem azotu i fosforu, w biologicznej oczyszczalni ścieków. Optymalizator MPC do implementacji sprzężenia zwrotnego z obiektu potrzebuje tych estymat. Dodatkowo aktualizowane muszą być parametry modelu Gray-Box wykorzystywanego w module MPC. Wtedy estymaty stanu są używane przez...
-
Set-Bounded joined parameter and state estimation for model predictive control of integrated wastewater treatment plant systems at medium time scale.
PublikacjaW artykule opisano moduł łącznej estymacji w postaci zbiorów ograniczonych (ang. set-bounded) parametrów i stanu systemu dla potrzeb sterowania predykcyjnego zintegrowanym systemem ściekowym w średniej skali czasu. Jest to jeden ze składowych elementów Inteligentnej Hierarchicznej Struktury Sterowania opracowanej w celu pokonania następujących problemów, które występują w kontrolowanym systemie: różne skale czasowe procesów, silnie...
-
Model based evaluation of plant improvement at a large wastewater treatment plant (WWTP)
PublikacjaIn this work, the effect of the improvement carried out at a large-scale wastewater treatment plant (WWTP) was evaluated, by means of modelling works, with the aim to determine the influence of the modernization over the process performance. After modernization, the energy consumption due to the aeration decreased about a 20% maintaining the effluent quality. In order to double-check the good effluent quality, modelling works were...
-
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant.
PublikacjaThe occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, b-lactam/b-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale...
-
Removal of selected sulfonamides and sulfonamide resistance genes from wastewater in full-scale constructed wetlands
PublikacjaSulfonamides are high-consumption antibiotics that reach the aquatic environment. The threat related to their presence in wastewater and the environment is not only associated with their antibacterial properties, but also with risk of the spread of drug resistance in bacteria. Therefore, the aim of this work was to evaluate the occurrence of eight commonly used sulfonamides, sulfonamide resistance genes (sul1–3) and integrase genes...
-
Application of subsurface vertical flow constructed wetlands to reject water treatment in dairy wastewater treatment plant
PublikacjaThe paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d-1 in...
-
Integrated plant-wide modelling for evaluation of the energy balance and greenhouse gas footprint in large wastewater treatment plants
PublikacjaModern wastewater treatment plants (WWTPs) should maintain a balance between three combined sustainability criteria, including effluent quality, energy performance and greenhouse gas (GHG) emissions. All of these criteria were considered in the integrated plant-wide model developed in this study. The proposed model incorporates new features, including: (i) the addition of associated facilities to the overall energy balance and...
-
The role of colloidal and particulate organic compounds in idenitrification and EBPR occurring in a full-scale activatedsludge system
PublikacjaThe aim of this study was to determine the immediate effects of slowly biodegradable substrates on the denitrification capability andphosphate release/uptake interactions for a full-scale biomass process from the ''Wschod'' wastewater treatment plant (WWTP) in Gdansk (Poland). Since it is hard to distinguish the slowlybiodegradable substrate in a direct way, a novel procedure based on batch experiments was developed and implemented....
-
Comparative Study of Balancing SRT by Using Modified ASM2d in Control and Operation Strategy at Full-Scale WWTP
PublikacjaDetailed knowledge on the composition of the influent going into the wastewater treatment system is essential for the development of a reliable computer model. In the context of WWTPs (wastewater treatment plants), the wastewater characteristics are not only important for activated sludge system modelling, but also have an impact on the appropriate control of single unit operations. The aim of this study was to evaluate the concepts...
-
The role of SSVF and SSHF beds in concentrated wastewater treatment, design recommendation
PublikacjaThe return flows of reject water from sewage sludge dewatering alter the activated sludgeprocess in a conventional WWTP and increas TN concentration in final effluent from WWTPs.The objectives of the investigation carried out is to consider the application of sequential SS VFbeds and an SS HF bed for the treatment of highly polluted wastewater, namely reject waterfrom sewage sludge dewatering in a centrifuge (RWC). This paper aims...
-
Model-based identification of the dominant N2O emission pathway in a full-scale activated sludge system
PublikacjaActivated sludge models (ASMs), extended with an N2O emission module, are powerful tools to describe the operation of full-scale wastewater treatment plants (WWTPs). Specifically, such models can investigate the most contributive N2O production pathways and guide towards N2O and carbon footprint (CF) mitigation measures. A common practice is to develop and validate models using data from a single WWTP. In this study, a successfully...
-
Comparison of two model concepts for simulation of nitrogen removal at a full-scale biological nutrient removal pilot plant
PublikacjaCelem badań było porównanie zdolności predykcyjnych dwóch mechanistycznych modeli procesu osadu czynnego (ASM1 i ASM3). W tym celu wykorzystano bazę danych empirycznych z pilotowej oczyszczalni ścieków Gummerwald w Hanowerze (Niemcy). Oba badane modele prognozowały szczytowe stężenia azotu amonowego na poziomie >8 gN/m3 w ciągu, którego obciążenie hydrauliczne wzrastało czterokrotnie w porównaniu do okresu bezdeszczowego. Prognozowany...
-
Atimicrobial Resistance of Enterococcus spp. in Muncipal wasterwater Treatment Plant - Model Study
PublikacjaIn this study the removal of resistant Enterococcus spp. was evaluated using the laboratory-scale wastewater treatment model plant (M-WWTP), designed as a multiphase (anaerobic, anoxic and aerobic) system (Q = 27 dm3 per day) and continuously supplied with the wastewater obtained from the full-scale WWTP, after grid. The activated sludge from the secondary clarifier was recirculated to the anaerobic chamber (with the ratio equal...
-
Removal of indicator bacteria from treated wastewater using physical and chemical methods. Pilot plant study.
PublikacjaEven after highly efficient biological processes the effluents from wastewater treatment plants may contain significant number of fecal bacteria, from 104 to 106 CFU/100 mL. Since no standards are set on the bacteriological quality of treated wastewater in Poland the elimination of bacterial contaminants is not a priority in wastewater treatment policy. Thus microbiological hazards become particularly significant in the situation...
-
The role of SSVF and SSHF beds in concentrated wastewater treatment, design recommendation
PublikacjaThe return flows of reject water from sewage sludge dewatering alter the activated sludge process ina conventional WWTP and increase TN concentration in the final effluent from WWTP. The objectiveof the investigation carried out was to consider the application of multistage treatment wetland(MTW) for the treatment of reject water from sewage sludge dewatering in a centrifuge (RWC). Thispaper aims to present the design and performance...
-
The effect of aeration mode (intermittent vs. continuous) on nutrient removal and greenhouse gas emissions in the wastewater treatment plant of Corleone (Italy)
PublikacjaThe paper reports the results of an experimental study aimed at comparing two configurations of a full-scale wastewater treatment plant (WWTP): conventional activated sludge (CAS) and oxic-settling-anaerobic process (OSA) with intermittent aeration (IA). A comprehensive monitoring campaign was carried out to assess multiple parameters for comparing the two configurations: carbon and nutrient removal, greenhouse gas emissions, respirometric...
-
The advanced monitoring as a key factor for appropriate optimization and control of full-scale activated sludge systems – case study Debogorze WWTP.
PublikacjaComputer simulation has become a helpful tool in wastewater treatment systems performance and effectiveness analysis. Advanced monitoring, by using appropriate software, enables to create a mathematical model of a real wastewater treatment plant (WWTP), run a simulation and subsequently interpret results under various conditions. An operation of WWTP is usually controlled by global parameters such as flow, solids retention time,...
-
Strategies for mitigating nitrous oxide production and decreasing the carbon footprint of a full-scale combined nitrogen and phosphorus removal activated sludge system
PublikacjaNitrous oxide (N2O) emitted from biological nutrient removal activated sludge systems contributes significantly to the total carbon footprint of modern wastewater treatment plants. In the present study, N2O production and emissions were experimentally determined in a large-scale plant (220,000 PE) employing combined nitrogen (N) and phosphorus (P) removal. As a modelling tool, the Activated Sludge Model 2d (ASM2d) was extended...
-
Evaluating the effect of different operational strategies on the carbon footprint of wastewater treatment plants – case studies from northern Poland
PublikacjaNowadays, low greenhouse gas (GHG) emission is expected at wastewater treatment plants (WWTPs). However, emission quantification and evaluation still faces difficulties related to data availability and uncertainty. The objective of this study was to perform carbon footprint (CF) analysis for two municipal WWTPs located in northern Poland. Slupsk WWTP is a large biological nutrient removal (BNR) facility (250,000 PE) which benefits...