Filtry
wszystkich: 33
Wyniki wyszukiwania dla: MEASUREMENTS OF RESPIRATION
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublikacjaThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublikacjaRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Evaluation of Respiration Rate Using Thermal Imaging in Mobile Conditions
PublikacjaRespiratory rate is very important vital sign that should be measured and documented in many medical situations. The remote measurement of respiration rate can be especially valuable for medical screening purposes (e.g. severe acute respiratory syndrome (SARS), pandemic influenza, etc.). In this chapter we present a review of many different studies focused on the measurements and estimation of respiration rate using thermal imaging...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublikacjaIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Using wearable device for biomedical signal acquisition and processing
PublikacjaIn this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...
-
System supporting behavioral therapy for children with autism
PublikacjaIn this paper, a system supporting behavioral therapy for autistic children is presented. The system consists of sensors network, base station and a brooch indicating person's emotional states. The system can be used to measure values of physiological parameters that are associated with changes in the emotional state. In the future, it can be useful to inform the autistic child and the therapist about the emotional state of the...
-
Open smart glasses development platform for AAL applications
PublikacjaThis paper describes an open platform for multi sensory electronic glasses that supports new and enhanced methods for intelligent interaction with patients, with smart objects, or to be used as new data input modalities like proximity sensor or smart textile interfaces. All the activities have been developed, investigated and evaluated within EU CHIST-ERA eGlasses project...
-
Evaluation of respiration rate and pattern using a portable thermal camera
PublikacjaThe goal of this paper was to analyze the accuracy of the proposed method for the evaluation of respiration rate and respiration rhythm patterns (e.g. inspiration slope) using the portable and mobile thermal camera module that could be a part of smart glasses. Parameters were analyzed for 12 volunteers in two experiments, when subjects speak and do not speak. The pressure, chest belt was used as a reference measurement method....
-
Analysis of the parameters of respiration patterns extracted from thermal image sequences
PublikacjaRemote estimation of vital signs is an important and active area of research. The goal of this work was to analyze the feasibility of estimating respiration parameters from video sequences of faces recorded using a mobile thermal camera. Different estimators were analyzed and experimentally verified. It was demonstrated that the respiration rate, periodicity of respiration, and presence and length of apnea periods could be reliably...
-
Respiration rate estimation for model predictive control of dissolved oxygen in wastewater treatment plant
PublikacjaRespiration rate is very important parameter for biological processes in wastewater treatment plant (WWTP). The sequential algorithm for estimate the respiration rate is proposed and investigated. The Kalman filter (KF) is used. Simulation tests for the benchmark WWTP are presented.Respiracja jest bardzo ważnym parametrem dla prawidłowego przebiegu procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono i zbadano...
-
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublikacjaA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
The motion influence on respiration rate estimation from low-resolution thermal sequences during attention focusing tasks
PublikacjaGlobal aging has led to a growing expectancy for creating home-based platforms for indoor monitoring of elderly people. A motivation is to provide a non-intrusive technique, which does not require special activities of a patient but allows for remote monitoring of elderly people while assisting them with their daily activities. The goal of our study was to evaluate motion performed by a person focused on a specific task and check...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublikacjaThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children
PublikacjaIn this article the procedure of selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children is proposed. Authors designed and conducted an experiment in which a group of 30 health volunteers (16 females and 14 males) were examined. Under controlled conditions people were exposed to a stressful situation caused by the picture or sound (1kHz constant sound, which was gradually...
-
HPLC-coupled post-column derivatization aims at characterization and monitoring of plant phytocomplexes, not at assessing their biological properties
PublikacjaTwo recent decades of research identified a number of environmental factors as well as mechanisms leading to pathogenic processes in the human organism. A common factor in pathogenesis of many diseases is oxidative stress, a condition in which the production of damaging reactive oxygen species (ROS), present in the body as an inevitable consequence of respiration and exacerbated by the inflammatory response and by exogenous factors...
-
QRS Morphology-Based EDR Signal—Factors Determining its Properties
PublikacjaRespiration-induced signals contain a clinically significant information. It could be obtained utilizing both direct and indirect methods. ECG-Derived Respiration (EDR) method is the latter one. However, in this case, two approaches could be distinguished. First one is based on determining changes in the morphology of QRS complexes while the second one is based on the Respiratory Sinus Arrhythmia (RSA) mechanism. The former approach...
-
A body position influence on ECG derived respiration
PublikacjaAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
Self diagnostics using smart glasses - preliminary study
Publikacjan this preliminary study we analyzed the possibility of the reliable measurement of biomedical signals with some potential hardware extensions of smart glasses. Using specially designed experimental prototypes four category of biomedical signals were measured: electrocardiograms, electromyograms, electroencephalograms and respiration waveforms. Experi- ments with volunteers proved that using even simple construc- tion of sensors...
-
Effect of long-term cold storage on physicochemical attributes and bioactive components of kiwi fruit cultivars
PublikacjaVarious kiwi fruit cultivars, bred in Korea, were kept in cold storage for 8–24 weeks for possible increase of their quality. Firmness significantly decreased at initial time in all cultivars.The rate of softeningwas the slowest in “Hayward”, followed by “Hort16A”, “Haenam”, “Daheung”, “Bidan”, “Hwamei”, and “SKK 12”. Sensory value increased with decreasing of firmness. Soluble solids content increased with storage time while acidity gradually...
-
A detector of sleep disorders for using at home
PublikacjaObstructive sleep apnea usually requires all-ni ght examination in a specialized clinic, under the supervision of a medical staff. Because of those requirements it is an expensive and a non-widely utilized test. Moving the examination procedure to patients’ home with automatic analysis algorithms involved will decrease the costs and make it available for larger group of patients. The developed device allows all-night recordings...