Filtry
wszystkich: 62
Wyniki wyszukiwania dla: MOSA ARRESTERS, LEAKAGE CURRENT, DIAGNOSTICS
-
Determining the leakage current resistive component by the orthogonal vector method
PublikacjaThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Immunity of residual current devices to the impulse leakage current in circuits with variable speed drives
PublikacjaThis paper concerns reliability of supply in variable speed drive circuits with residual current devices. During normal operation of these circuits high value of leakage current causes unwanted tripping of residual current devices. Immunity of residual current devices to the impulse leakage current should be evaluated. The system for testing of residual current devices and results of the test are presented
-
Supply current signal and artificial neural networks in the induction motor bearings diagnostics
PublikacjaThis paper contains research results of the diagnostics of induction motor bearings based on measurement of the supply current with usage of artificial neural networks. Bearing failure amount is greater than 40% of all engine failures, which makes their damage-free operation crucial. Tests were performed on motors with intentionally made bearings defects. Chapter 2 introduces the concept of artificial neural networks. It presents...
-
Technical diagnostics and monitoring of traction current collectors
PublikacjaNew evaluation methods of the technical condition of rolling stock current collectors are proposed in this paper. The method of automatic measurement of the pantograph static force characteristic, realized when the vehicle runs through the test section of the track with especially prepared overhead line height distribution, has been practically implemented by the Polish Railways. The method of testing the slipper spring suspension...
-
Current measurement and analysis for induction motor diagnostics
PublikacjaPrzedstawiono sposób diagnozowania łożysk tocznych w silnikach indukcyjnych z wykorzystaniem pomiarów i analizy prądu zasilającego silnik. Zaprezentowano metodę pomiarową i opracowania danych diagnostycznych. Uzyskano zgodność częstotliwości składowych widma prądu otrzymanych z badań teoretycznych i eksperymentalnych.Podano wyniki badań łożysk o róznych uszkodzeniach i prawdopodobieństwa poprawnych diagnoz.
-
Diagnostics of induction motors by means of current supplying measurements
PublikacjaSkładowe prądu zasilającego silnik, które związane są z uszkodzeniami łożysk są małe w porównaniu z dominującą składową sieciową. Zaproponowano układ pomiarowy do ich pomiaru i przedstawiono wyniki badań diagnostycznych na obiektach rzeczywistych.
-
Automated Diagnostics of Current Pick-Up Disturbances in Electric Traction Networks
PublikacjaThe present work defines the basic causes of bow disturbances of current pick-up, sets a task of establishing a system of automated control of bow disturbances at feeder zones of electric traction networks, proposes structural variants of the technical system implementation, describes the algorithm of detection of bow disturbances of current pick-up.
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Remote sensing in laboratory diagnostics of reinforced concrete elements – current development and vision for the future
PublikacjaContinuous emergence of new concrete types and kinds of reinforcement, as well as technological solutions in the field of structural engineering have made great demand for diagnostic tests of reinforced concrete elements. New challenges and problems facing people require new more efficient tools for laboratory diagnostics than those commonly used. Remote sensing may be the answer to this demand. In this paper the author describes...
-
Remote sensing in laboratory diagnostics of reinforced concrete elements – current development and vision for the future
PublikacjaContinuous emergence of new concrete types and kinds of reinforcement, as well as technological solutions in the field of structural engineering have made great demand for diagnostic tests of reinforced concrete elements. New challenges and problems facing people require new more efficient tools for laboratory diagnostics than those commonly used. Remote sensing may be the answer to this demand. In this paper the author describes...
-
Low current transformer utilizing Co-based amorphous alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Wykorzystanie modelu silnika indukcyjnego klatkowego do prądowej diagnostyki jego łożysk. Application of induction machine model for current diagnostics of bearings
PublikacjaW pracy podano widmo prądu stojana dla silnika normalnego oraz wprawianego w drgania o nastawianej częstotliwości. Drgania korpusu wirnika skutkują uginaniem się wirnika, co symuluje bicie wirnika od uszkodzenia łożysk. Podano też model matematyczny silnika, dopuszczający niecentryczność wirnika. Podano widmo prądu stojana przy pracy z wibracjami wirnika odwzorowującymi w pewnym przybliżeniu wibracje od uszkodzonych łożysk.
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Induction machine model for current diagnostics of bearings. W: [CD-ROM]Proceedings and our Portrait. 48 Internationales Wissenschaftliches Kollo- quium. Ilmenau, 22.-25.09.2003. Ilmenau: Tech. Univ. Ilmenau**2003 s. [1-9] 8 rys. Model maszyny indukcyjnej dla prądowej diagnostyki łożysk.
PublikacjaPojawienie się określonych typów uszkodzeń w silniku jest źródłem odkształ-cenia tego prądu. Poddając przebieg prądu analizie widmowej obserwuje sięszereg składowych, które związane są z określonymi typami uszkodzeń. Referatprezentuje rezultaty badań modelowych i eksperymentalnych. Badania przepro-wadzono na silniku 1,1 kW czterobiegunowym. Zaprezentowany model pozwala za-równo na wprowadzanie wibracji wirnika jak ekscentryczności...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Residual current devices in installations with PV energy sources
PublikacjaThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...