Filtry
wszystkich: 4995
-
Katalog
- Publikacje 4247 wyników po odfiltrowaniu
- Czasopisma 20 wyników po odfiltrowaniu
- Konferencje 9 wyników po odfiltrowaniu
- Osoby 63 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Kursy Online 38 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 612 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MULTI-PHASE FLOW
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublikacjaRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Influence of PWHT Parameters on the Mechanical Properties and Microstructural Behavior of Multi-Pass GTAW Joints of P92 Steel
PublikacjaThe 9% Cr steels were developed for ultra-supercritical (USC) power plants to meet the requirements of high operating temperature and pressure. These steels are produced to operate at high temperatures where impact toughness is not a concern; however, it becomes important for the welded joints to have good impact toughness at room temperature for manufacturing. The present work investigates the effect of the post-weld heat treatment...
-
Rapid Design Centering of Multi-Band Antennas Using Knowledge-Based Inverse Models and Response Features
PublikacjaAccounting for manufacturing tolerances as well as uncertainties concerning operating conditions and material parameters is one of the important yet often neglected aspects of antenna development. Appropriate quantification of uncertainties allows for estimating the fabrication yield but also to carry out robust design (e.g., yield maximization). For reliability reasons, statistical analysis should be executed at the accuracy level...
-
The efficiency and technological reliability of biogenic compounds removal during long-term operation of a one-stage subsurface horizontal flow constructed wetland
PublikacjaThe paper presents the results of a study of the efficiency and technological reliability of total nitrogen and total phosphorus removal during long term operation of a one-stage constructed wetland system with subsurface horizontal wastewater flow. The flow rate of the wastewater treatment plant was 1.2m3/d during the research period. Physical and chemical analyses of raw wastewater and treated effluent were carried out in the...
-
Sensitive simultaneous determination of 19 fluorobenzoic acids in saline waters by solid-phase extraction and liquid chromatography–tandem mass spectrometry
PublikacjaA solid-phase extraction (SPE) procedure using C18 stationary phase was optimized for the preconcentration of 19 fluorinated derivatives of benzoic acid (FBA): mono-, di-, tri-, and tetrafluorosubstituted in the ring, trifluoromethylbenzoic acid and 3,5-bistrifluoromethyl benzoic acid from undiluted salt-rich (>20%) reservoir waters. Quantitative (>90%) retention/elution of 16 out of 19 analyte compounds was achieved allowing a...
-
Preparation and evaluation of 1,3-alternate 25,27-bis-(pentafluorobenzyloxy)-26,28-bis-(3-propyloxy)-calix[4]arene-bonded silics gel high performance liquid chromatography stationary phase
PublikacjaA 1,3-alternate 25,27-bis-(pentafluorobenzyloxy)-26,28-bis-(3-propyloxy)-calix[4]arene-bonded silica gel stationary phase (CalixBzF10) was synthesized, structurally characterized, and used as a selector in liquid chromatography. The selectivity study of this phase was done by using fluorine-containing compounds (fluorobenzenes, fluoro-pyrimidine bases), as well as non-fluorinated analytes (non-steroidal anti-inflammatory drugs,...
-
SiC-based phase-shift dual half bridge DC-DC converter as a key component of multilevel cascaded MV converters
PublikacjaThe paper describes SiC-based dual half bridge (DHB) DC-DC converter considered as a key component of high frequency isolated multilevel cascaded medium voltage converters. Two topologies of bi-directional DC-DC converters: the resonant half-bridge DC-DC converter and the phase-shift DHB converter are compared in the paper. Experimental results of SiC-based 50 kHz DHB DC-DC converter are presented in the paper.
-
Reduced-Cost Microwave Design Closure by Multi-Resolution EM Simulations and Knowledge-Based Model Management
PublikacjaParameter adjustment through numerical optimization has become a commonplace of contemporary microwave engineering. Although circuit theory methods are ubiquitous in the development of microwave components, the initial designs obtained with such tools have to be further tuned to improve the system performance. This is particularly pertinent to miniaturized structures, where the cross-coupling effects cannot be adequately accounted...
-
A multi‑criteria approach to investigate spatial distribution,sources, and the potential toxicological effect of polycyclic aromatic hydrocarbons (PAHs) in sediments of urban retention tanks
PublikacjaBottom sediments deposited in retention tanks (RTs) located on two urban streams (Oliwski and Strzyza) in the central part of Gdansk (Poland) were analysed for polycyclic aromatic hydrocarbons’ (PAHs) content. PAHs were extracted from samples with methylene chloride, then the extracts were subjected to clean-up applying the solid phase extraction (SPE) method. Quantitative and qualitative determination of 16 PAHs was performed...
-
High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
PublikacjaAn optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...