Wyniki wyszukiwania dla: POWER MEASUREMENT
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublikacjaThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Induction Motor Multiscalar Model Based Sensorless Control Using Power Measurement
Publikacja -
Measurement of the muon stopping power in lead tungstate
Publikacja -
The measurement of input power of power supply in network disturbed by low frequency distortions
PublikacjaIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Designing a magnetoacoustic emission measurement configuration for measurement of creep damage in power plant boiler tubes
PublikacjaOpisywane są własności skonstruowanego detektora emisji magneto-akustycznej (EMA) służącego dla pomiaru stopnia degradacji rurociągów w przemyśle energetycznym. Specjalna budowa biegunów magnesu umożliwia ich dopasowanie do zakrzywionych powierzchni. Układ pomiarowy pozwala na badanie natężenia EMA dla pola wzdłuż osi rury, a także w kierunku obwodowym. Wykazano, iż możliwa jest detekcja zmiany stopnia degradacji materiału na obwodzie...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublikacjaW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
The Effect of the Phenomenon of “Spectrum Leakage” on the Measurement of Power Quality Parameters
Publikacja -
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublikacjaThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Optimal Placement of Phasor Measurement Unit in Power System using Meta-Heuristic Algorithms
PublikacjaThe phasor measurement units (PMUs) play an important and vital role in power system monitoring and controlling, since they provide the power system phasors stamped with a common real time reference through a global positioning system (GPS). Indeed, from economical point of view it is not possible to set PMUs in all system buses due to the high cost and the requirement of more complex communication...
-
Electrical power measurement of reference SOFC fueled by biogas mixture at 750 C
Dane BadawczeThe dataset contains the electrical measurements of IV curves for SOFC without La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer working under biogas and H2 feeding stream. The SOFC was reduced at 900C and conditioned for 12 h under H2 prior the measurements. The measurements were performed using Gamry potentiostat/galvanostat
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublikacjaThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
A Set of Low-power Microcontroller-based Modules Used for Testing of Small Energy Measurement Methods
PublikacjaEstimation of energy consumption of low-power devices is not widely discussed in the scientific literature, but this topic is getting more and more popular. Evaluation process of newly developed methods and instrumentation requires carefull treatment. In order to fulfill this niche, the set of micro-power microcontroller based devices was proposed. The devices represent typical energy consuption profiles and allow experimental verification...
-
Electrical power measurement of LSCNT modified SOFC fueled by biogas mixture at 750 C
Dane BadawczeThe dataset contains the electrical measurements of IV curves for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer working under biogas and H2 feeding stream. The SOFC was reduced at 900C and conditioned for 12 h under H2 prior the measurements. The measurements were performed using Gamry potentiostat/galvanostat
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Power grid frequency measurement in LabVIEW environment using the least mean squares method to signal phase approximation in the presence of noise
Publikacja -
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
O wyszukiwaniu niepoprawnych pomiarów w systemach DCS obiektów energetycznych = On search for incorrect measurement results in distributed control systems (DCS) of power objects
PublikacjaPrzedyskutowano problem rozpoznawania degradacji mierników pomiarowych w systemach DCS dużych obiektów energetycznych, przy równoczesnym występowaniu degradacji eksploatacyjnej urządzeń składowych tych obiektów. Zastosowano sieć neuronową (SNN) o skokowych funkcjach przejścia. Zastosowana SNN wykazała wysoką jakość. Sprawdzono możliwości rozpoznawania obu typów degradacji występującej w zastosowaniu do tzw. degradacji dwukrotnych.
-
Selected results of measurements carried out in a ship power station with two generators working in parallel with the use of the NI PXIe-1062Q based measurement system
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (A/E v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering, of Gdynia Maritime University. The attached data set contains the results of measurements made...
-
Remote current measurement with FPGA digital processing
PublikacjaThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....