Filtry
wszystkich: 1293
-
Katalog
- Publikacje 1086 wyników po odfiltrowaniu
- Czasopisma 1 wyników po odfiltrowaniu
- Osoby 16 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 19 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 166 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: co2 equivalent unit
-
Technical and economic conditions of supplying residential consumers with heat from nuclear power plant
PublikacjaThe reduction of CO2 emission requires technological shift towards carbon-free options. Cogeneration of electricity and heat based on coal and natural gas will experience generation cost increase, if the costs of emissions are imposed on the plant operators. Therefore, nuclear and renewable options should be considered. In this paper, we present the concept of electricity and heat supply system with nuclear condensing turbine adapted...
-
Spatial distribution of CO2, O2, CO, NO and temperature within a biowaste composting pile
Dane BadawczeThe dataset contains the color-coded isophlets illustrating the spatial distribution of gas concentrations (CO, CO2, O2 and NO) and the temperature in biowaste composting pile during 6 weeks of process. Four cross sections and two longitudinal cross sections (the left and right sides of the pile) were made using Surfer 10 software (Golden Software,...
-
Performance of cryogenic oxygen production unit with exhaust gas bleed for sewage sludge gasification and different oxygen purities
PublikacjaThe paper presents a thermodynamic analysis of the integration of a cryogenic air separation unit into a negative CO2 emission gas power plant. The power cycle utilizes sewage sludge as fuel so this system fits into the innovative idea of bioenergy with carbon capture and storage. A cryogenic air separation unit integrated with the power plant was simulated in professional plant engineering and thermodynamic process analysis software....
-
Carbon balance of SOFC fueled by biogas mixture at 750 C
Dane BadawczeThe dataset contains the calculated carbon balance for the SOFC fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Carbon activity coefficients of SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C - longterm
Dane BadawczeThe dataset contains the calculated carbon activity coefficient for the SOFC and SOFC with LSCNT layer (La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s) fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Reaction quotients of reforming reactions for SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C - longterm
Dane BadawczeThe dataset contains the calculated reaction quotients of reforming reactions for the SOFC and SOFC with LSCNT layer (La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s) fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Change of exhaust gases concentration for SOFC fueled by H2 and biogas mixture at 750 C
Dane BadawczeThe dataset contains the Change of exhaust gases concentration for SOFC fueled by H2 (for 12h) and biogas mixture at 750 C (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Change of catalytic parameters for SOFC fueled by H2 and biogas mixture at 750 C
Dane BadawczeThe dataset contains the Change of catalytic parameters for SOFC fueled by H2 and biogas mixture at 750 C (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit. The parameters are conversion rates, selectivities and yields of products
-
Carbon Dioxide Recovery Skid
PublikacjaIn the face of tightening climate regulations, the adoption of carbon dioxide recovery systems is inevitable. Modular process skid units have been widely adopted across the industry. The gas-steam power plant skid unit with the carbon dioxide recovery system was described. The proposed skid module consists of the compact cycle with the oxy-combustion and the carbon dioxide capture skid unit producing pure compressed CO2. The compactness...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublikacjaSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Combined operation of 900MW power plant with the ORC through the bleed steam extraction point and CO2 recovery system
PublikacjaThe work presented here is aimed at utylisation of waste heat in the reference supercritical power plant in the manner to produce electricity in ORC installation. The waste heat is available in the form of a stream of hot water at 90 C, recovered from the exhaust gases in the amount of 200MW. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. Therefore an original approach...
-
Measurements of raising of 160EC pantograph type
Dane BadawczeIn this description the results of the experiment and also simulation performed on the total assembly of the 160 EC pantograph type is given. Multibody dynamics of pantograph rising due to external torque and forces are measured for parameter validation of the pantograph model.
-
Constant vs. Variable Efficiency of Electric Drive in Train Run Simulations
PublikacjaTrain run simulations, which focus on various power- and energy-oriented aspects, should reflect the losses in the electric powertrain. In general, the powertrain efficiency varies with respect to load and speed. Including this relation in simulation requires knowledge about detailed drivetrain parameters, which are often unavailable. This paper verifies the possibility to approximate the drivetrain efficiency in train run simulations...
-
Exergetic Analysis of the nCO2PP Cycle with Particular Reference to the Exergy Destruction of Sewage Sludge Due to Gasification
PublikacjaAn exergy analysis is carried out on the negative CO2 emission gas power plant (nCO2PP), which integrates the process sections of fuel preparation, power generation and carbon capture. Processes of exergy destruction are studied with particular focus on the process in the gasification unit of the fuel preparation section, where a large amount of exergy is destroyed in various chemical reactions from sewage sludge to producer gas...
-
Compact High Efficiency and Zero-Emission Gas-Fired Power Plant with Oxy-Combustion and Carbon Capture
PublikacjaReduction of greenhouse gases emissions is a key challenge for the power generation industry, requiring the implementation of new designs and methods of electricity generation. This article presents a design solution for a novel thermodynamic cycle with two new devices—namely, a wet combustion chamber and a spray-ejector condenser. In the proposed cycle, high temperature occurs in the combustion chamber because of fuel combustion...
-
Influence of Thermal Decomposition of Wood and Wood-Based Materials on the State of the Atmospheric Air. Emissions of Toxic Compounds and Greenhouse Gases
PublikacjaThis paper presents the energy characteristics of wood and wood-based materials in the form of commercially available pellets, furniture board (MDF) and OSB. Toxicometric indices were determined for gaseous destructs arising from thermal decomposition and combustion of the materials studied. The paper proves that combustion conditions are crucial in terms of toxic destructive emissions. It has been shown that the combustion of...
-
Influence of metallic porous microlayer on pressure drop and heat transfer of stainless steel plate heat exchanger
PublikacjaThe experimental analysis of passive heat transfer intensification in the case of plate heat exchanger has been carried out. The metallic porous layer was created on the heat transfer surface of analyzed unit. The experiment was accomplished in two stages. In the first stage the commercial stainless steel gasketed plate heat exchanger was investigated, while in the second one – the identical heat exchanger but with the modified...
-
Thermodynamic and economic analysis of nuclear power unit operating in partial cogeneration mode to produce electricity and district heat
PublikacjaThis paper presents the methodology of techno-economic analysis for a nuclear unit operating in partial cogeneration mode and its application for the case study: a nuclear power plant planned in Poland. The research objectives were: to propose EPR, AP1000 and ESBWR nuclear condensing-extraction turbine systems modifications required for operation in cogeneration, to determine optimal heat production and heat transport line (HTL)...
-
How to evaluate methods used in chemical laboratories in terms of the total chemical risk? – a ChlorTox Scale
PublikacjaReliable assessment of the health and environmental risk associated with the use of chemicals is critical to ob- jectively evaluate the greenness and whiteness of an analytical method. An objective and useful way of risk assessment should take into account all the relevant properties of used substances, their actual amounts needed for application of the method, and quantify the assessment result using a standardized unit. This...
-
Optimizing the computation of a parallel 3D finite difference algorithm for graphics processing units
PublikacjaThis paper explores the possibilities of using a graphics processing unit for complex 3D finite difference computation via MUSTA‐FORCE and WENO algorithms. We propose a novel algorithm based on the new properties of CUDA surface memory optimized for 2D spatial locality and compare it with 3D stencil computations carried out via shared memory, which is currently considered to be the best approach. A case study was performed for...