Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 2372
-
Catalog
displaying 1000 best results Help
Search results for: ON-LINE AUTOMATIC ANALYZER
-
Comparison of thresholding algorithms for automatic overhead line detection procedure
PublicationThe article presents an overview of the thresholding algorithms. It compares the algorithms proposed by Pun, Kittler, Niblack, Huang, Rosenfeld, Remesh, Lloyd, Riddler, Otsu, Yanni, Kapur and Jawahar. Additionally, it was tested how the tuning of the Pun, Jawahar and Niblack methods affects the thresholding efficiency and proposed a combination of the Pun algorithm with a priori algorithm. All presented algorithms have been implemented...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Monitoring of volatile organic compounds (VOCs) in atmospheric air. Part I. On-line gas analyzers
PublicationThe paper reviews the subject literature concerning the analytical instruments routinely used for monitoring volatile organic compounds in atmospheric air. The analyzers are classified as stationary or mobile according to their ease of transport. Stationary DOAS (Differential Optical Absorption Spectroscopy) analyzer is characterized, as are MIMS (Membrane Introduction Mass Spectrometry), MESI (Membrane Extraction with Sorbent...
-
The influence of meteorological conditions and anthropogenic activities on the seasonal fluctuations of BTEX in the urban air of the Hanseatic city of Gdansk, Poland
PublicationThe results of studies conducted in Gdansk in the period from January to December 2013 and focused on the determination of BTEX in the atmospheric air are presented. At the stage of the isolation and/or enrichment of analytes from the gaseous medium, a passive sampling technique—Radiello® diffusive passive samplers, was applied. The time-weighted average annual concentration of benzene, toluene, ethylbenzene, and total xylenes...
-
Determination of non-steroidal anti-inflammatory drugs in natural waters using off-line and on-line SPE followed by LC coupled with DAD-MS
PublicationOpisano dwie metody pozwalające na jednoczesne oznaczanie zawartości niesterydowych leków przeciwzapalnych (difluisal, diklofenak, naproksen, tolmetin, fenoprofen, ibuprofen) w próbkach wodnych. Próbki przygotowywano do analizy z użyciem techniki ekstrakcji do fazy stałej (off-line i on-line). Natomiast oznaczeń końcowych dokonano z użyciem LC-DAD-MS. Sprawdzono kilka różnych kolumienek ekstrakcyjnych i wybrano RP-18 jako najlepsze...
-
Usługi on-line w kontekście mobilnym - jakościowe badanie obserwacyjne
PublicationArtykuł przedstawia wyniki badania obserwacyjnego, majacego na celu zidentyfikowanie czynników kształtujących u użytkowników chęć skorzystania z usług on-line za pomocą urządzeń mobilnych takich jak smartfon, tablet lub laptop. Przeprowadzono badania obserwacyjne, w których użytkownicy (7 osób) przez 14 dni notowali swoją aktywność w zakresie korzystania z usług on-line z dostępnych urządzeń w powiązaniu z czynnikami uznawanymi...
-
Elipsometric data analysis used in on-line metal passivation monitoring
PublicationWykorzystano technikę elipsometrii monochromatycznej do opisu on-line warstw tlenkowych, elektroosadzanych na miedzi. Elipsometria jest w stanie dostarczyć informacji odnośnie grubości i współczynników załamania światła układów warstwowych, jednakże wymagane w tym celu jest zbudowanie matematycznego modelu odwzorowującego stałe optyczne układu badanego. W powyższej pracy przedyskutowane zostały różne metody dopasowywania modelu...