Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 3298
-
Catalog
- Publications 2691 available results
- Journals 28 available results
- Conferences 1 available results
- People 58 available results
- Projects 10 available results
- Laboratories 1 available results
- Research Teams 1 available results
- Research Equipment 1 available results
- e-Learning Courses 85 available results
- Events 4 available results
- Open Research Data 418 available results
displaying 1000 best results Help
Search results for: SPECTROSCOPIC/ELECTROCHEMICAL MONITORING
-
Application of electrochemical noise technique in corrosion monitoring
PublicationTechnika szumu elektrochemicznego od ponad 20 lat stanowi przedmiot intensywnych badań mających na celu jej praktyczne zastosowanie w monitorowaniu korozji. U podstaw omawianej metody leży odpowiednia analiza rejestrowanych symultanicznie przebiegów prądowych i potencjałowych. W zależności od użytej techniki obróbki danych uzyskane mogą być informacje dotyczące ilościowych (szybkość) i jakościowych (rodzaj zaatakowania) cech procesu...
-
Low-coherence photonic method of electrochemical processes monitoring
PublicationWe present an advanced multimodality characterization platform for simultaneous optical and electrochemical measurements of ferrocyanides. Specifcally, we combined a fber-optic Fabry– Perot interferometer with a three-electrode electrochemical setup to demonstrate a proof-ofprinciple of this hybrid characterization approach, and obtained feasibility data in its monitoring of electrochemical reactions in a boron-doped diamond flm...
-
On electrochemical noise analysis for monitoring of uniform corrosion rate
PublicationSzybkość korozji jest określona przez rezystancję polaryzacyjną warstwy metal-elektrolit. Jej wartość może być wyznaczona za pomocą pomiarów szumów elektrochemicznych. Przedstawiono szczegółowo algorytm wyznaczania wartości rezystancji polaryzacyjnej na podstawie rejestrowanych sygnałów losowych dla przykładowych wyników badań eksperymentalnych. Oszacowano dokładność wyznaczanej wartości.
-
Anion binding by p-aminoazobenzene-derived aromatic amides: spectroscopic and electrochemical studies
PublicationThe synthesis and complexing properties of p-aminoazobenzene-derived mono-, bis-, and trisamides were described. Ligands 3 and 4 bind anions, including fluorides, chlorides, bromides, acetates, benzoates, dihydrogen phosphates, hydrogen sulfates, and p-toluenesulfonates, in chloroform forming 1 : 1 complexes. The highest value of stability constant was evaluated for the 4-F− complex (log K = 5.63 ± 0.21). On the basis of 1H NMR,...
-
Towards spectroscopic monitoring of photoelectrodes: In-situ Raman photoelectrochemistry of a TiO2/prussian blue photoanode
PublicationHere, novel in-situ Raman photoelectrochemical measurements are performed. The obtained results have proved that it is possible to track the progress of a photoelectrochemical reaction that takes place on a semiconducting electrode using the spectroscopic method. As an exemplary system, the Ti/TiO2/Prussian blue electrode is investigated. Since TiO2 is an n-type semiconductor, it cannot act as an efficient anode in dark conditions....
-
Evaluation of the Commercial Electrochemical Gas Sensors for the Monitoring of CO in Ambient Air
PublicationAir pollution is a growing concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. For air pollution monitoring a wide range of stationary gas and particulate analysers can be used....
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublicationThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Simultaneous opto-electrochemical monitoring of carbamazepine and its electro-oxidation by-products in wastewater
PublicationThe growing human impact on aquatic environments, due to the extensive use of pharmaceuticals and the release of persistent pollutants, makes it necessary to implement new widespread methods for the characterisation and quantification of such contaminants and relative degradation products. Carbamazepine, 5H-dibenzo[b,f]azepine-5-carboxamide, (CBZ) is a widely used anti-epileptic drug, characterised by its limited removal by conventional...
-
The electrochemical determination of isatin at nanocrystalline boron-doped diamond electrodes: stress monitoring of animals
PublicationUltra-thin nanocrystalline boron-doped diamond electrodes (B:NCD) were used for the electrochemical determination of isatin in dog urine samples using cyclic voltammetry and square wave voltammetry in a phosphate buffer saline, pH = 7.2. No additional modification or pretreatment of the electrode surface was required in this approach, being of high importance for the facile detection procedure. The increase of the peak current...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publication