Filters
total: 105
filtered: 100
Search results for: AND DETECTORS
-
Evaluating calibration and robustness of pedestrian detectors
PublicationIn this work robustness and calibration of modern pedestrian detectors are evaluated. Pedestrian detection is a crucial perception com- ponent in autonomous driving and here we study its performance under different image corruptions. Furthermore, we provide analysis of classifi- cation calibration of pedestrian detectors and we show a positive effect of using style-transfer augmentation technique. Our analysis is aimed as a step...
-
Evaluating Calibration and Robustness of Pedestrian Detectors
Publication -
Data acquisition methods for GEM detectors
Publication -
Light box for investigation of characteristics of optoelectronics detectors
PublicationIn this paper, a light box for investigation of characteristics of optoelectronic detectors is described. The light box consists of an illumination device, an optical power sensor and a mechanical enclosure. The illumination device is based on four types of high-power light emitting diodes (LED): white light, red, green and blue. The illumination level can be varied for each LED independently by the driver and is measured by optical...
-
Digital techniques for noise reduction in CCD detectors
Publication -
Bismuth germanate and bismuth silicate glasses in cryogenic detectors.
PublicationStwierdzono, że przewodnictwo elektryczne redukowanych szkieł silnie zależy od temperatury, czasu reakcji i koncentracji Bi. Zależność przewodnictwa elektrycznego od temperatury jest dobrze opisana przez funkcję ĺ~exp[-(T0/T)n,gdzie n=1/4. Współczynnik emisji wtórnej elektronów jest praktycznie niezależny od stopnia redukcji ale znacznie rośnie po domieszkowaniu szkieł alkalicznymi jonami. Badania dowiodły, że modyfikowane...
-
Ceramics, Glass and Glass-Ceramics for Personal Radiation Detectors
Publication -
Detection of neutrons with LiF fluorescent nuclear track detectors
Publication -
LITHIUM FLUORIDE CRYSTALS AS FLUORESCENT NUCLEAR TRACK DETECTORS
Publication -
Selected perowskite type LSFO thin films for the infrared detectors
PublicationPrzedstawiono technologię wytwarzania cienkich warstw ceramicznych tlenków lantanowo-strontowo-żelazowych (LSFO). Zaprezentowano konstrukcję bolometrycznych detektorów podczerwieni wykonanych z opracowanych warstw. Przedstawiono charakterystyki prądowo-napięciowe wybranych detektorów, wyniki pomiaru ich szumów i termicznej stałej czasowej. Przedstawione detektory były w stanie wykryć obiekt o temperaturze 38 stopni Celcjusza znajdujący...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Comparative study on the effectiveness of various types of road traffic intensity detectors
PublicationVehicle detection and speed measurements are crucial tasks in traffic monitoring systems. In this work, we focus on several types of electronic sensors, operating on different physical principles in order to compare their effectiveness in real traffic conditions. Commercial solutions are based on road tubes, microwave sensors, LiDARs, and video cameras. Distributed traffic monitoring systems require a high number of monitoring...
-
Time Projection Chamber (TPC) detectors for nuclear astrophysics studies with gamma beams
Publication -
Radio-photoluminescence of highly irradiated Lif:Mg,Ti and Lif:Mg,Cu,P detectors
Publication -
Analysis of metals in air particles from Gdańsk and London with EDX/EDS detectors in electron microscope
PublicationElectron microscopy with energy dispersive X-ray spectrometry (EDX/EDS) is the example of non-destructive analytical method for surface elemental analysis, with a potential detection limit of 0.1-0.5 wt.% for most elements. A spatial resolution <10 nm can be achieved using this technique, which provides a basis for the generation of quantitative and qualitative elemental data for individual particles. In order to obtain quantitative...
-
Composite thermoluminescent detectors based on the Ce3+ doped LuAG/YAG and YAG/LuAG epitaxial structures
Publication -
Range-based method of alpha-particle spectrometry using LiF fluorescent nuclear track detectors
Publication -
Comparison of High Performance Liquid Chromatography Methods with Different Detectors for Determination of Steroid Hormones in Aqueous Matrices
PublicationThis paper presents the development and comparison of procedures for the qualitative and quantitative determination of five estrogenic compounds (17-a-ethynylestradiol, estrone, estradiol, estriol, and progesterone) in drinking water and wastewater samples. Five extraction columns and two disks were tested for their efficiency. The C18 columns were superior on the basis of cost for solid phase extraction of drinking water or sewage....
-
Measurements of high-temperature emission spectra of highly irradiated LiF:Mg,Cu,P (MCP-N) TL detectors
Publication -
Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions
Publication -
Spectral characteristic of high-dose high-temperature emission from LiF:Mg,Cu,P (MCP-N) TL detectors
Publication -
CALIBRATION OF LOW ENERGY X-RAY EXPERIMENTAL SETUP WITH STRONGLY FILTERED BEAM USING DATA FROM A SEMICONDUCTOR AND A THERMOLUMINESCENT DETECTORS
Publication -
New OSL detectors based on LiMgPO4 crystals grown by micro pulling down method. Dosimetric properties vs. growth parameters
Publication -
3D dose verification with polymer gel detectors of brain-spine match line for proton pencil beam cranio-spinal: A preliminary study
Publication -
Microdosimetric analysis of response of LiF:Mg,Cu,P (MCP-N) TL detectors for alpha-particles and ultra-high doses of gamma-rays
Publication -
Radial distribution of dose within heavy charged particle tracks – Models and experimental verification using LiF:Mg,Cu,P TL detectors
Publication -
Analysis of airborne metal containing particles with EDX/EDS detectorsin electron microscopes
PublicationIn years 2006-2010 particulate matter analysis was undertaken for dust samples collected from Gdansk and London area in orderto compare their morphology and composition. Part of those studies was devoted to analysis of particulate matter (PM) bearingmetals. Characterization of the morphology and size of the particles collected onto the filters was performed using a scanning electronmicroscope (SEM) and transmission electron microscope...
-
Intrinsic energy resolution of NaI(Tl)
Publication -
Characterization of CaWO4 scintillator at room and liquid nitrogen temperatures
Publication -
Energy resolution and light yield non-proportionality of ZnSe:Te scintillator studied by large area avalanche photodiodes and photomultipliers
Publication -
Energy resolution and non-proportionality of the light yield of pure CsI at liquid nitrogen temperatures
Publication -
Application of EARL (ResEARch 4 Life®) protocols for [18F]FDG-PET/CT clinical and research studies. A roadmap towards exact recovery coefficient
Publication -
Large Area Avalanche Photodiodes in X-rays and scintillation detection
Publication -
Recent advances in gaseous imaging photomultipliers
Publication -
GEM-based gaseous photomultipliers for UV and visible photon imaging
Publication -
Studies of scintillation light nonproportionality of ZnSe(Te), CsI(Tl) and YAP(Ce) crystals using heavy ions
Publication -
Avalanche photodiodes in scintillation detection
Publication -
Comparison of LaCl3:Ce and NaI(Tl) scintillators in γ-ray spectrometry
Publication -
A high-energy resolution observed from a YAP:Ce scintillator
Publication -
Low-temperature spectroscopic and scintillation characterisation of Ti-doped Al2O3
Publication -
Progress in GEM-based gaseous photomultipliers
Publication -
Large area avalanche photodiodes in scintillation and X-rays detection
Publication -
Cavity parameters identification for TESLA control system development
Publication -
Superconducting cavity driving with FPGA controller
Publication -
TESLA cavity modeling and digital implementation in FPGA technology for control system development
Publication -
Application of gas chromatography to the analysis of spirit-based alcoholic beverages
PublicationSpirit-based beverages are alcoholic drinks, which production processes are dependent on the type and origin of raw materials. The composition of this complex matrix is difficult to analyze and scientists commonly choose a gas chromatography techniques for this reason. With a wide selection of extraction methods and detectors it is possible to provide qualitative and quantitative analysis for many chemical compounds with a various...
-
Measurements of Dispersed Phase Velocity in Two-Phase Flows in Pipelines Using Gamma-Absorption Technique and Phase of the Cross-Spectral Density Function
PublicationThis paper concerns the application of the gamma radiation absorption method in the measurements of dispersed phase velocity in two-phase flows: liquid–gas flow in a horizontal pipe- line and liquid–solid particles in a vertical pipe. Radiometric sets containing two linear 241Am gamma radiation sources and two NaI(Tl) scintillation detectors were used in the research. Due to the stochastic nature of the signals obtained from the...
-
Parametric impulsive noise detector for corrupted audio signals based on hidden Markow model
PublicationThe paper addresses the problem of impulsive noise detection for audio signals. A structure of threshold parameter detectors using modelingof signals was introduced. the algorithm of the noise detection, based on discrete-time hidden Markow model (HMM)of whitened audio signal is elaborated
-
Transportable, Portable and Micro Gas Chromatographs
PublicationSignificant benefits can be obtained by miniaturization of conventional benchtop gas chromatographs. The attractive features arising from miniaturization include low-power requirements, low heat capacity of separation columns, low consumption of mobile phase, enhanced performance, higher portability, and easily coupling to detectors and secondary chromatographic systems. In separation sciences, including gas phase separations,...
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...