Search results for: near-infrared
-
Theory and application of Near-infrared spectroscopy
PublicationIn recent years one can observe a significant increase in the requirements on quality control in all industrial sectors. The growing number of involved analyses makes the traditional, time consuming, requiring use of large quantities of reagents, thus expansive methods inconvenient especially for industrial applications. Fortunately, there is a very fast, cheap and not invasive analytical method that is increasingly used in qualitative...
-
Comparison of near infrared spectroscopy (NIRS) and near-infrared transillumination-backscattering sounding (NIR-T/BSS) methods
PublicationThe aim of the study was to compare simultaneously recorded a NIR-T/BSS and NIRS signals from healthy volunteers. NIR-T/BSS is a device which give an ability to non-invasively detect and monitor changes in the subarachnoid space width (SAS). Experiments were performed on a group of 30 healthy volunteers (28 males and 2 females, age 30.8 ± 13.4 years, BMI = 24.5 ± 2.3 kg/m2). We analysed recorded signals using analysis methods based...
-
JOURNAL OF NEAR INFRARED SPECTROSCOPY
Journals -
Application of the near-infrared spectroscopy in the pharmaceutical technology
PublicationNear-infrared (NIR) spectroscopy is currently the fastest-growing and the most versatile analytical method not only in the pharmaceutical sciences but also in the industry. This review focuses on recent NIR applications in the pharmaceutical technology. This article covers monitoring, by NIR, of many manufacturing processes, such as granulation, mixing or drying, in order to determine the end-point of these processes. In this...
-
Higly efficient near-infrared organic excimer electrphosphorescent diodes
PublicationW pracy opisano konstrukcję diody elektrofosforescencyjnej z emiterem w postaci organicznego kompleksu platyny (II). Dioda wysyła promieniowanie w bliskiej podczerwieni (705-720nm) pochodzące od ekscymerów trypletowych. Maksymalna użyteczna wydajność kwantowa diody wynosi 9.8-10.7%.
-
Formation and Near-Infrared Emission of CsPbI3 Nanoparticles Embedded in Cs4PbI6 Crystals
Publication -
Near-Infrared Fluorescence Image-Guided Surgery in Esophageal and Gastric Cancer Operations
Publication -
Ultra-high-efficiency near-infrared Ga2O3:Cr3+ phosphor and controlling of phytochrome
Publication -
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublicationIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Ultraviolet to near-infrared down-conversion in Bi3+–Yb3+ co-doped YAM phosphor
Publication -
Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy
PublicationIntroduction: Fluorescence-based navigation for breast cancer sentinel node biopsy is a novel method that uses indocyanine green as a fluorophore. However, methylene blue (MB) also has some fluorescent properties. This study is the first in a clinical series presenting the possible use of MB as a fluorescent dye for the identification of sentinel nodes in breast sentinel node biopsy. Material and methods: Forty-nine patients with...
-
Hidden Structural Evolution and Bond Valence Control in Near-Infrared Phosphors for Light-Emitting Diodes
Publication -
Chromium Ion Pair Luminescence: A Strategy in Broadband Near-Infrared Light-Emitting Diode Design
Publication -
The Quantum Efficiency Roll-Off Effect in Near-Infrared Organic Electroluminescent Devices with Iridium Complexes Emitters
PublicationThe electroluminescence quantum efficiency roll-off in iridium(III)-based complexes, namely Ir(iqbt)2(dpm) and Ir(iqbt)3(iqbt=1 (benzo[b]thiophen-2-yl)-isoquinolinate, dpm=2,2,6,6-tetramethyl-3,5-heptanedionate) utilized as near-infrared emitters in organic light emitting diodes with remarkable external quantum efficiencies, up to circa 3%, 1.5% and 1%, are measured and analyzed. With a 5–6 weight % of emitters embedded...
-
Multi-Site Cation Control of Ultra-Broadband Near-Infrared Phosphors for Application in Light-Emitting Diodes
Publication -
Super Broadband Near-Infrared Phosphors with High Radiant Flux as Future Light Sources for Spectroscopy Applications
Publication -
Monitoring of subarachnoid space and cerebrovascular pulsation with near-infrared transillumination/back scattering : new aspects of the method
PublicationW pracy zaprezentowano nowe aspekty nieinwazyjnej metody NIRT-BS w zastosowaniu do zapisu zmian szerokości przestrzeni podpajęczynówkowej (SAS) jako źródła informacji o amplitudzie tętnienia naczyń na powierzchni mózgu.
-
Near-Infrared-Triggered Nitrogen Fixation over Upconversion Nanoparticles Assembled Carbon Nitride Nanotubes with Nitrogen Vacancies
Publication -
Penetrating Biological Tissue Using Light-Emitting Diodes with a Highly Efficient Near-Infrared ScBO3:Cr3+ Phosphor
Publication -
Ultra-Broadband Phosphors Converted Near-Infrared Light Emitting Diode with Efficient Radiant Power for Spectroscopy Applications
Publication -
Determination of API content in a pilot-scale blending by near-infrared spectroscopy as a first step method to process line implementation
PublicationNear infrared (NIR) spectroscopy was used for estimation of powder blend homogeneity and manufacturing control of a medicinal product powder mixture containing active pharmaceutical ingredient (API). Aiming at initiating a Process Analytical Technology (PAT) activity, the first step was a stationary mode atline evaluation. In this, the content of pharmaceutical active compound in the powder mixtures intended to the direct tabletting...
-
Technical foundations for noninvasive assessment of changes in the width of the subarachnoid space with near-infrared transillumination-backscattering sounding (NIR-TBSS)
PublicationPraca opisuje metodę transiluminacji w bliskiej podczerwieni umożliwiającą nieinwazyjne monitorowanie zmian szerokości przestrzeni podpajęczynówkowej oraz amplitudy tętnienia naczyń powierzchniowych mózgu.
-
Near-Infrared III Nanophosphorswith Cr3+Ni2+ Energy Transfer for Bioimaging
Open Research DataIn the biomedical field, the use of fluorescence imaging in the second near-infrared (NIR-II) region is growing rapidly because it imparts the advantages of reduced autofluorescence and low photon scattering. The advantage of reduced scattering is that it increases penetration depth in vivo and improves imaging clarity. Herein, this work uses mesoporous...
-
New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination/backscattering sounding, part 2: clinical verification in the patient
PublicationW pracy przedstawiono porównanie wyników symulacji propagacji promieniowania z zakresu bliskiej podczerwieni z danymi uzyskanymi na drodze pomiarów wykonanych w warunkach klinicznych. Różnice między nimi nie przekraczały 4 dB, co potwierdziło słuszność przyjętych założeń w procesie symulacji. W pomiarach wykorzystano unikatowy zetstaw nadajników i odbiorników promieniowania podczerwonego, pozwalającego prowadzenie pomiarów transmisji...
-
New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination/backscattering sounding, part 1: Monte Carlo numerical modeling
PublicationW pracy wykorzystano zmodyfikowaną metodę Monte Carlo do numerycznego modelowania propagacji promieniowania z zakresu bliskiej podczerwieni w warstwach anatomicznych głowy. Badano efekt zmian szerokości warstwy podpajęczynówkowej pod wpływem tętna na natężenie promieniowania wstecznie rozpraszanego. Przeprowadzone obliczenia pokazały, że możliwe jest monitorowanie zmian tej szerokości na podstawie pomiarów transmisji promieniowania...
-
Surface-Protected High-Efficiency Nanophosphors via Space-Limited Ship-in-a-Bottle Synthesis for Broadband Near-Infrared Mini-Light-Emitting Diodes
Publication -
Spectral analysis of mechanical and respiratory influences on width of subarachnoid space assessed with non-invasive method of near-infrared transillumination/back scattering sounding
PublicationW pracy przedstawiono zastosowanie analizy widmowej do badania zmian szerokości przestrzeni podpajęczynówkowej spowodowanych ruchami głowy i wysilonym oddechem w nieinwazyjnej metodzie transiluminacji w bliskiej podczerwieni.
-
Use of Near Infrared Transillumination/Back Scattering Sounding (NIR-T/BSS) to assess effects of elevated intracranial pressure on width of subarachnoid space and celebrovascular pulsation in animals
PublicationW pracy dokonano ocenę zmiany szerokości przestrzeni podpajęczynówkowej i tętnienia naczyń mózgowych w czasie chwilowego zwiększenia ciśnienia śródczaszkowego u królików doświadczalnych. Badania zostały przeprowadzone przy wykorzystaniu metody transiluminacji w bliskiej podczerwieni z rozpraszaniem zwrotnym NIRT-BSS.
-
Enhancement of self-trapped excitons and near-infrared emission in Bi3+/Er3+ co-doped Cs2Ag0.4Na0.6InCl6 double perovskite
Open Research DataErbium (Er) complexes are used as optical gain materials for signal generation in the telecom C-band at 1540 nm, but they need a sensitizer to enhance absorption. Na+ substitution for Ag+ and Bi3+ doping at the In3+ site is a possible strategy to enhance the broadband emission of Cs2AgInCl6, which could be used as a sensitizer for energy transfer to...
-
Chromium Cluster Luminescence: Advancing Near‐Infrared Light‐Emitting Diode Design for Next‐Generation Broadband Compact Light Sources
Open Research DataIn modern technology devices, an energy-saving miniature near-infrared (NIR) light source plays a critical role in non-destructive, non-invasive sensing applications and further advancement of technology. This dataset reports the broadband NIR luminescence of Cr3+ clusters for designing phosphor-converted NIR light-emitting diodes as an alternative...
-
The luminescence study of Sr2−xSrxPN3:Eu2+ nitridophosphate.
Open Research DataIn this work, a series of Ca2−xSrxPN3:Eu2+ nitridophosphate phosphors through a solid-solution strategy involving a hot isostatic press was developed by collaborators from National Taiwan University. Unexpected dual emissions in the red and infrared regions are observed, different from previous research results. The unique change in red and near-infrared...
-
The luminescence study of CsPbI3 nanoparticles embedded in Cs4PbI6 crystals.
Open Research DataCs4PbI6, as a rarely investigated member of the Cs4PbX6 (X is a halogen element) family, has been successfully synthesized atlow temperatures by collaborators from National Taiwan University. Strong red to near-infrared (NIR) emission properties have been detected, and its optical emission centers have been identified to be numerous embedded perovskite-type...
-
Studies on the influence of β-cyclodextrin derivatives on the physical stability of famotidine
PublicationThe usage of Fourier transform infrared spectroscopy, near infrared spectroscopy, differential scanning calorimetry and microscopy is presented in this work focused on the exploration of the effect of CD on the physical stability of famotidine (FAM). The most significant information was achieved by analysis of the second derivatives ofnear infrared (NIR) spectra recorded. Changes in the shape of spectra derivatives allow...
-
The luminescence study of Sc2(1–x)Ga2xO3:Cr3+/4+ coumpounds
Open Research DataThe growing interest in the use of near-infrared (NIR) radiation for spectroscopy, optical communication, and medical applications spanning both NIR-I (700–900 nm) and NIR-II (900–1700 nm) has driven the need for new NIR light sources. NIR phosphor-converted light-emitting diodes (pc-LEDs) are expected to replace traditional lamps mainly due to their...
-
Effects of laser pulse duration in two-photon vision threshold measurements
PublicationPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 194
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 194, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 192
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 192, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 191
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 191, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 193
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 193, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 190
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 190, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Short Term Monitor of Photodegradation Processes in Ranitidine Hydrochloride Observed by FTIR and ATR FTIR
PublicationThe effects of degradation of ranitidine hydrochloride exposed to UVB radiation (l = 310 nm) and oxygen in a weathering chamber were studied by Fourier Transform Infrared spectroscopy (FTIR) and Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR). ATR-FTIR profile indicated that the degradation was spatially heterogeneous. Significant amounts of photoproducts were detected only in a directly...
-
The luminescence study of Ca14Zn6Ga10−xMnxO35 coumpounds.
Open Research DataManganese in the pentavalent state (Mn 5+) is both rare and central in materials exhibiting narrow-band near-infrared (NIR) emission and is highly sought after for phosphor-converted light-emitting diodes as promising candidates for future miniature solid-state NIR light source. We develop the Ca 14 Zn 6 Ga 10−x Mn x O 35 (x = 0.3, 0.5, 1.0, 1.25, 1.5,...
-
Sport-related concussion alters cerebral hemodynamic activity during controlled respiration
PublicationThis study investigated cerebral hemodynamic activity following sport-related concussion. Prefrontal cortex oxygenation was assessed by near-infrared spectroscopy (NIRS) during a controlled breathing protocol. Wavelet transformation of the NIRS signals showed significant decreases in HbO2 and HbD amplitude at the respiratory frequency interval (0.10–0.6 HZ) from preseason baseline to acute concussion. These results suggest a decreased...
-
Application of vibrational spectroscopy, thermal analyses and X-Ray diffraction in the rapid evaluation of the stability in solid-state of ranitidine, famotidine and cimetidine
PublicationThis paper reports the study on applicability of Fourier transform infrared (FTIR), near-infrared (NIR) and Raman spectroscopy, differential scanning calorimetry (DSC) and X-ray diffraction (XRD) for the estimation of the chemical stability and photostability of histamine H2-receptor antagonist substances. Ranitidine hydrochloride (RAN), famotidine (FAM) and cimetidine (CIM) were tested and differences in sensitivity were measured...
-
Transiluminacyjne monitorowanie stanu przestrzeni podpajęczynówkowej
PublicationTransiluminacja tkanek ludzkiego ciała w celach diagnostycznych jest stosowana od ponad stu lat. Metoda transiluminacji w bliskiej podczerwieni z rozpraszaniem zwrotnym (NIRT-BSS) umożliwia ciągłe, bezinwazyjne monitorowanie zmian szerokości przestrzeni podpajęczynówkowej, które może być cennym narzędziem w ocenie zagrożenia obrzękiem mózgu. W rozprawie przedstawiono optyczny model rozchodzenia się promieniowania podczerwonego...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublicationAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Effects of consecutive apneas on pial artery pulsation and subarachnoid width in healthy subjects
PublicationHypercapnia is known to dilate the pial artery, disrupt cerebral autoregulation and increase pial artery pulsation. The cerebral blood flow velocity (CBFV) response to hypercapnia is biphasic. Below the threshold for the increase of blood pressure (BP) with carbon dioxide partial pressure (pCO2), the CBFV measurement reflects vascular reactivity to pCO2 alone at a constant BP. Above this threshold, the CBFV measurement provides...
-
The luminescence study of Ga2–x(Al0.68In0.32)xO3:Cr3+ coumpounds.
Open Research DataNear-infrared (NIR) phosphor-converted light-emitting diodes (pc-LEDs) are a highly efficient perspective NIR light source, with application hindered by a narrow emission band. In this work, we broaden the emission of a new series of NIR phosphors by controlling crystal structure disorder through cation cosubstitution. By substituting Ga3+ with (Al0.68In0.32)3+,...
-
Effect of Maximal Breath Hold Apnea on Pial Artery Pulsation and Subarachnoid Width in Human
PublicationLittle is known about intracranial pressure (ICP)-cerebral hemodynamic interplay during maximal breath-hold apnea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Changes in sas-TQ correlate with ICP to a considerable extent, whereas cc-TQ reflects the functional...
-
Solid state versus fiber picosecond infrared lasers applied to two-photon vision tests
PublicationDevelopment of new microperimetric tools dedicated for imaging of early functional changes in the retina may help in the monitoring of various ocular diseases progression e.g. Age-Related Macular Degeneration. Recently described two-photon vision may be applied to microperimetric devices. Many subjects with well-known disease history could be investigated with newly developed instrumentation that tests ability of human eye to perceive...