Search results for: Thick sandwich plate
-
Edge-Guided Mode Performance and Applications in Nonreciprocal Millimeter-Wave Gyroelectric Components
PublicationThe analogies between the behavior of gyromagnetic and gyroelectric nonreciprocal structures, the use of the simple transfer matrix approach, and the edge-guided (EG) wave property, supported in a parallel plate model for integrated magnetized semiconductor waveguide, are investigated in those frequency regions, where the effective permittivity is negative or positive. As with their ferrite counterparts, the leakage of the EG waves...
-
Ultimate compressive strength assessment of uncleaned and cleaned corroded plates with locked crack
PublicationThe work presented here investigates the structural response of cleaned corroded plates, subjected to compressive load in the presence of a locked crack, where the change of mechanical properties as a result of corrosion development and the cleaning process is also accounted for. A Finite Element model for assessing the compressive strength, considering geometric and material nonlinearities, is developed, and the analysed plates...
-
A gap waveguide-based mechanically reconfigurable phase shifter for high-power Ku-band applications
PublicationThis paper presents a novel design of a low-loss, reconfgurable broadband phase shifter based on groove gap waveguide (GGW) technology. The proposed phase shifter consists of a folded GGW and three bends with a few pins forming the GGW and one bend attached to a movable plate. This movable plate allows for adjustments to the folded waveguide length, consequently altering the phase of electromagnetic waves. The advantage of GGW...
-
The bridge over Regalia River in Szczecin - design and construction.
PublicationNowoclowa Route is the largest projekt in Szczecin, that consists of 11 km of roads 3,3 km bridges and viaducts, including three parallel bridges across Regalica River (the east arm of Odra River), 535 m long, with the spans: 59+90+90+116+116+64m. The bridge structure consist of two steel plate girders composite with reinforced concrete deck slab. The design and the construction of the bridge are described in the paper.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022674301]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [1130063002268251]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022676211]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022682591]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022678341]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022673001]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022671121]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022671911]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022679361]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672001]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022674311]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022677291]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672521]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022677921]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [3300730069467331]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022677911]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672721]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022689611]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022684341]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672511]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022682451]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022689851]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022675301]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022683681]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022671391]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022674991]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022685121]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672211]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022674191]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022674851]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022678601]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022671661]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672051]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672971]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Electrical properties of lead-borate glasses and glass-ceramics containing iron ions
Open Research DataElectrical properties were studied for borate-lead glasses and glass-ceramics doped with iron ions. Glass samples of composition of xFe2O3–(100 − x)(B2O3–2PbO) (2.5 b x b 37, in mol%) were prepared by the conventional melt quenching technique. The melting was conducted in alumina crucibles at the temperature of 1523 K. The melts were poured on a preheated...
-
Dielectric properties of barium-vanadate glasses
Open Research DataThe linear impedance of barium-vanadate glasses was measured. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar. The melting was...
-
The structure of vanadate glasses containing BaTiO3.
Open Research DataThe structure of vanadate glasses doped with BaTiO3 was measured by SEM technique. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
Linear impedance of vanadate glass-ceramics containing BaTiO3
Open Research DataThe linear impedance of vanadate glass-ceramics containing BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
The topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope
Open Research DataThe topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Przyczółki mostowe wspomagane konstrukcjami z gruntu zbrojonego
PublicationW referacie przedstawiono syntezę prac związanych z oceną projektów przyczółków wykorzystujących odciążenie w postaci konstrukcji z gruntu zbrojonego geosyntetykami, realizowanych na drogach ekspresowych S3 i S7. W ramach przeprowadzonych audytów dokonano oceny zastosowanych rozwiązań szczegółowych i materiałów jak również obliczeń zamieszczonych w projektach. Zwrócono szczególną uwagę na przestrzenną prace bloków z gruntu zbrojonego...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
Kompozytowy most dla pieszych. Badania doświadczalne i przygotowanie do projektowania
PublicationDysertacja powstała w ramach grantu badawczego NCBiR, pt. „Opracowanie kompozytowych przęseł mostów dla pieszych do zastosowania nad drogami GP”, nr PBS1/B2/6/2013. Głównym celem pracy było wsparcie procesu projektowania kompozytowego mostu pieszo-rowerowego. Zakres pracy obejmuje badania doświadczalne elementów kompozytowych GFRP, walidację modeli obliczeniowych oraz wykorzystanie aparatu analizy wrażliwości do procesu projektowego....