Search results for: DENSITY VISCOSITY REFRACTIVE INDEX TOLUENE IONIC LIQUID
-
Density, sound velocity, viscosity, and refractive index of new morpholinium ionic liquids with amino acid-based anions: Effect of temperature, alkyl chain length, and anion
PublicationIn this work, room temperature synthesis of twenty new ionic liquids (ILs) based on the N-alkyl-N-methylmorpholinium ([Mor1,R], R = 2, 3, 4, 6, 8) cation and N-acetyl-L-amino acid anions (L-alaninate, L-valinate, L-leucinate, L-isoleucinate) was described. The synthesized ILs were characterized by various spectroscopic techniques and high-resolution mass spectrometry. Furthermore, density (ρ), sound velocity (v), viscosity (η)...
-
Thermodynamic study of binary mixtures of toluene with ionic liquids, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, 1-hexyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide and 1-butylpyridinium bis(trifluoromethylsulfonyl)imide
PublicationDensities, refractive indices and viscosities at 293.15, 298.15, 303.15, 308.15 and 313.15 K of binary mixtures of toluene with 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, 1-hexyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide and 1-butylpyridinium bis(trifluoromethylsulfonyl)imide have been measured over the miscible region at p = 0.1 MPa. From the experimental data, values of excess molar volume,...
-
Thermodynamic study of binary mixtures of 2-propanol with ionic liquids, 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, 1-hexyl-3-methylimidazolium trifluoromethanesulfonate and triethylhexylammonium bis(trifluoromethylsulfonyl)imide
PublicationIn this work, densities, speeds of sound, refractive indices and viscosities of three binary mixtures containing the ionic liquids 1-hexyl-3-methylimidazolium bis(trifluoromethyl-sulfonyl)imide, 1-hexyl-3-methylimidazolium trifluoromethanesulfonate and triethylhexyl-ammonium bis(trifluoromethylsulfonyl)imide, mixed with 2-propanol at wide temperature and composition ranges at atmospheric pressure have been measured. From these...
-
Separation of toluene from gas phase using supported imidazolium ionic liquid membrane
PublicationInvestigation on utilization of supported ionic liquids membranes for hydrocarbon separation from the gas phase was performed. Properties of membrane phase, wettability of supports, swelling effects and solubility of toluene were taken into account. Toluene permeation rates were significantly higher than those of pure nitrogen, the selectivity in a range of 17–341 was satisfying for separation. Despite the increase of viscosity...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Effectiveness of toluene separation from gas phase using supported ammonium ionic liquid membrane
PublicationAmmonium ionic liquids (ILs) are relatively cheap in synthesis and environmentally benign and despite that they have been very rarely used in gas separation. In this research we used several ammonium ILs as liquid membranes for removal of residual toluene from gas phase. Ionic liquids used in this study were composed of bis(trifluoromethylsulfonyl)imide anion [Tf2N] and trimethylbutylammonium [N1114], trietylbutylammonium [N2224],...
-
DFT studies of the refractive index of boron-doped diamond
PublicationThe density functional theory is one of the optimal solutions in calculation of optical properties of materials on the quantum scale. In this paper, we have investigated the refractive index of a boron-doped diamond structure with the usage of Atomistic Toolkit software from Synopsys. During this study, various methods and pseudopotentials were checked to obtain an optimal performanceaccuracy method for calculation of such materials....
-
Temperature-dependent structure-property modeling of viscosity for ionic liquids
PublicationIn this paper we present the methodology for assessing the ionic liquids' viscosity at six temperature points (25, 35, 45, 50, 60 and 70 [C]), which utilizes only the in silico approach. The main idea of such assessment is based on the "correction equation" describing the correlation between experimentally measured viscosity and theoretically derived density (calculated with use of molecular mechanics), given at 6 different temperature...
-
Use of pyridinium and pyrrolidinium ionic liquids for removal of toluene from gas streams
PublicationSeparation of toluene from a toluene/N2 gas mixture using supported liquid membranes based on a series of pyridinium (1-butylpyridinium- bis(trifluoromethylsulfonyl)imide - [C4Py][Tf2N], 1-hexylpyridinium trifluoromethanesulfone [C6Py][Tf2N]) and pyrrolidinium (1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide - [C4Pyrr][Tf2N], 1-hexyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide - [C6Pyrr][Tf2N], 1-butyl-1-methylpyrrolidinium...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Predicting the viscosity and electrical conductivity of ionic liquids on the basis of theoretically calculated ionic volumes
PublicationSelected physical properties of the ionic liquids might be quantitatively predicted based on the volumes of the ions these systems are composed of. It is demonstrated that the ionic volumes calculated using relatively simple theoretical quantum chemistry methods can be utilised to estimate the viscosities and electrical conductivities of various commonly used ionic liquids. The fitting formulas of the exponential form are offered...
-
Transport properties of microemulsions with ionic liquid apolar domains as a function of ionic liquid content
PublicationThe specific conductivity, dynamic viscosity and apparent diffusion coefficient of each of four aqueous ionic liquid microemulsions (IL-MEs) were measured as a function of ionic liquid (IL) content. The investigated systems were composed of water, hydrophobic ILs (1-butyl-3-methylimidazolium hexafluorophosphate or bis(trifluoromethanesulphonyl)imide) and the nonionic surfactant Triton X-100 or its mixture with cosurfactant (butanol)....
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Response of a fiber-optic Fabry-Pérot interferometer to refractive index and absorption changes – modelling and experiments
PublicationThis paper describes how the refractive index and the absorption of investigated substances change the spectrum of the optical radiation at the output of the fiber-optic Fabry-Pérot interferometer. The modeling of the operation of the interferometer takes into account not only the spectra of the refractive index and the absorption of the medium that is inside the cavity, but also spectra of the refractive indices of the core and...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublicationOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublicationThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
ZnO coated fiber optic microsphere sensor for the enhanced refractive index sensing
PublicationOptical fiber-based sensors are expected to become key components in the control of industrial processes,and the tuning and the enhancement of their sensing properties are crucial for the further developmentof this technology. Atomic Layer Deposition (ALD), a vapor phase technique allowing for the deposition ofconformal thin films, is particularly suited for the deposition of controllable thin films on challenging sub-strates....