Electric shock hazard in circuits with variable-speed drives
PublicationThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Computer System for Evaluation of Shock Hazard in Circuits with Non-sinusoidal Earth Currents
PublicationEffects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents a computer system, based on LabVIEW environment,...
-
System of protection against electric shock for circuits with power electronics converters
PublicationModern low voltage circuits are very often equipped with power electronics converters, therefore in these circuits non-sinusoidal earth currents (touch currents) may occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based...
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublicationThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Protection against electric shock in electrical installations with low voltage generating sets
PublicationW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Protection Against Electric Shock Using Residual Current Devices in Circuits with Electronic Equipment
PublicationW artykule przedstawiono problematykę stosowania wyłączników różnicowoprądowych w obwodach z urządzeniami elektronicznymi, które powodują, że prąd różnicowy ma zmienną częstotliwość lub jest odkształcony. Wyniki badań wskazują, że częstotliwość obiegająca od znamionowej oraz zawartość wyższych harmonicznych w prądzie różnicowym niekorzystnie wpływa na skuteczność ochrony przeciwporażeniowej przy zastosowaniu wyłączników różnicowoprądowych....
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublicationDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublicationW referacie przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oszacowano wpływ tego odkształcenia na próg fibrylacji serca. Analizowano skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania zaproponowanego...
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublicationW artykule przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oceniono skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania proponowanego wyłącznika różnicowoprądowego.
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublicationEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublicationHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Potential changes in an electric field and electrolytic corrosion.
PublicationSources have been described of corrosively hazardous electric fields and methods of determination of the corrosion hazard to metal structures caused by electrolytic corrosion. Results of potential and impedance investigations in the field of stray currents flowing out of a tram traction and in the presence of a defined electric field of low frequency have been presented. Uncertainties have been indicated relating to the generally...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublicationThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Uziemienia w zespołach elektrowni wiatrowych
PublicationW pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Wavelet transform-based approach to defect identification in railway carbon contact strips.
PublicationPantographs of electric rail vehicles are fitted with carbon contact strips, which slide along the contact wire of catenary to provide constant electrical contact. Contact strips are exposed to wear and damages. Using damaged contact strips significantly increases the risk of catenary rupture. Therefore, their technical condition has to be inspected frequently. In previous work a 3D laser scanning system was proposed for recording...
-
Tripping of F-type RCDs for high-frequency residual currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Towards Safety Case Integration with Hazard Analysis for Medical Devices
PublicationSafety case is one of system safety lifecycle products and should be consistent with other lifecycle products like hazard analysis results. In this paper we present a method of safety case integration with hazard tables based on the use of parametrized argument patterns. We describe a hazard table metamodel, a safety argument pattern and a mechanism of pattern instantiation using a linking table which represents references to system...
-
Electric Machines Virtual Laboratory
e-Learning CoursesThis is an educational aid for students. It shows the environment of industrial application of electric machines and allows for a look inside them. Users can see the main components of the power system in its natural environment. This course is to allow access to the VR app – Electric Machines Virtual Laboratory.
-
SHOCK
Journals -
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Phosphorylation‐mediated regulation of heat shock response in Escherichia coli
PublicationEscherichia coli has two heat shock regulons under the transcriptional control of Esigma(32) and Esigma(E) RNA polymerases. These polymerases control the expression of genes, the products of which are needed for correct folding of proteins in the cytoplasm and the extracytoplasm respectively. In this study, we report that mutations in a tyrosine phosphatase-encoding gene led to decreased activity of these heat shock regulons. The...
-
Self-refraction of acoustic pulses with shock fronts in some nonequilibrium media
PublicationThe nonlinear self-refraction of acoustic pulsed beams, which include shock fronts, is studied. The medium of sound propagation is a gas where thermodynamically nonequilibrium processes take place, such as exothermic chemical reaction or excitation of vibrational degrees of a molecule’s freedom. Comparative analysis of the features of sound propagation over gases where pure nonlinear attenuation of the shock wave occurs, and gases...
-
Why are trees still such a major hazard to drivers in Poland?
PublicationRoadside trees are one of Poland's most serious road safety issues. Since 2009 more than 2800 people have been killed as a result of tree collisions; this represents about 15% of all of Poland's accident fatalities between 2009 and 2013. In some of the country's regions striking a tree caused more than 30% of all road accident fatalities. With no proper regulations, guidelines or examples of good practice, roadside environments...
-
ENHANCED EVAPORATION OF THE DROPLETS OF CONDENSATE IN THE ASYMMETRICAL SHOCK WAVE ZONE
PublicationIn the low-pressure part of steam turbine, the state path usually crosses the saturation line in penultimate stages [4,5]. The formation and evolution of these droplets lower the performance of the wet stages of the turbines, and their effects on the efficiency are collectively known as wetness losses [4]. Nowadays, due to work of steam turbines at partial load, process of homogeneous and heterogeneous condensation still is current....
-
Thermal Self-Action of Acoustic Beams Containing Several Shock Fronts
PublicationThermal self-action of an acoustic beam with one discontinuity or several shock fronts is studied in a Newtonian fluid. The stationary self-action of a single sawtooth wave with discontinuity (or some integer number of these waves), symmetric or asymmetric, is considered in the cases of self-focusing and self- defocusing media. The results are compared with the non-stationary thermal self-action of the periodic sound. Thermal self-action...