Filters
total: 6796
-
Catalog
- Publications 4986 available results
- Journals 154 available results
- Conferences 17 available results
- People 222 available results
- Projects 3 available results
- Research Equipment 1 available results
- e-Learning Courses 110 available results
- Events 2 available results
- Open Research Data 1301 available results
displaying 1000 best results Help
Search results for: non-linear control
-
A new approach to active noise and vibration control - [Part II: unknown frequency case]
PublicationThis paper presents a new approach to rejection of complex-valued sinusoidal disturbances acting at the output of a discrete-time stable linear plant with unknown and possibly timevarying dynamics. It is assumed that both the instantaneous frequency of the sinusoidal disturbance and its amplitude may be slowly varying with time and that the output signal is contaminated with wideband measurement noise. It is not assumed that a...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublicationThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Mathematical Models of Control Systems of Angular Speed of Steam Turbines for Diagnostic Tests of Automatic and Mechatronic Devices
PublicationAccurate modeling of physical processes of many automatics and mechatronics systems is often necessity. In power system such a process is control of angular velocity of power objects during connection to operation in parallel. This process is extremely dynamic. For this reason response of control system depends from changes of many physical parameters (temperature, pressure and flow of the medium, etc.). Precision modeling influences...
-
Example applications of control charts as a quality tool for statistical process control in a small manufacturing company
PublicationPraca zawiera przykład wdrożenia kart kontrolnych w małym zakładzie produkcyjnym zajmującym się wytwarzaniem komponentów z blach. Pokazano jak z zastosowaniem dostępnego pakietu biurowego, można stworzyć statystyczną kontrolę procesu(SPC)w małej firmie. Artykuł zawiera wyniki z przykładowych analizowanych procesów.
-
Softly switched model predictive control for control of integratedwastewater treatment system at medium time scale.
PublicationW przypadku gdy system jest sterowany za pomocą jednej, uniwersalnej strategii sterowania w pełnym zakresie jego obciążeń, powstają poważne trudności w znalezieniu optymalnego sterowania. W celu jak najlepszego dopasowania strategii sterowania do panujący warunków, zdefiniowano trzy stany operacyjne: normalny, zakłóceniowy oraz awaryjny. Dla tych stanów zaprojektowano odpowiednie strategie sterowania. W związku z tym pojawia się...
-
Fire Protection and Materials Flammability Control by Artificial Intelligence
PublicationFire safety has become a major challenge of materials developers because of the massive production of organic materials, often combustibles, and their use for different purposes. In this sense, fire safety is critically considered in the development of engineering materials [1, 2]. The multiplicity of parameters contributing to the development of formulation of flame-retardant materials from one side and the sustainability concerns...
-
Application of non-classical operational calculus to indicate hazards in numerical solutions of engineering problems
PublicationThe article addresses the application of non- classical operational calculus to approximative solutions of engineering problems. The engineering-sound examples show that a continuous–discrete problem transformation from differential unequivocal problem to a differential wildcard problem, triggering a change in solution quality. A number of approximative methods are capable to alter both quantitative and qualitative...
-
Indirect adaptive controller based on a self-structuring fuzzy system for nonlinear modeling and control
PublicationIn this paper, a unified nonlinear modeling and control scheme is presented. A self-structuring Takagi-Sugeno (T-S) fuzzymodel is used to approximate the unknown nonlinear plant based on I/O data collected on-line. Both the structure and theparameters of the T-S fuzzy model are updated by an on-line clustering method and a recursive least squares estimation(RLSE) algorithm. The rules of the fuzzy model can be added, replaced or...
-
Renewable natural resources as green alternative substrates to obtain bio-based non-isocyanate polyurethanes-review
PublicationCommercially available polyurethanes are synthesized by the polyaddition of diisocyanates with polyols and low molecular weight chain extenders. A new approach to polyurethanes synthesis is realized via non-isocyanate routes. Negative impacts of petroleum-based chemicals on the environment and human health as well as gradual reduction of fuel-based resources, which leads to an increase in their prices, are an incentive to looking...
-
ANALYSIS OF IMPACT of SHIP model parameters on changes of control quality index in ship dynamic positioning system
PublicationIn this work there is presented an analysis of impact of ship model parameters on changes of control quality index in a ship dynamic positioning system designed with the use of a backstepping adaptive controller. Assessment of the impact of ship model parameters was performed on the basis of Pareto-Lorentz curves and ABC method in order to determine sets of the parameters which have either crucial, moderate or low impact on objective...
-
Highly efficient maximum power point tracking control technique for PV system under dynamic operating conditions
PublicationThe application of small-scale electrical systems is widespread and the integration of Maximum Power Point Tracking (MPPT) control for Photovoltaic systems with battery applications further enhances the techno-economic feasibility of renewable systems. For this purpose, a novel MPPT control system using Dynamic Group based cooperation optimization (DGBCO) algorithm is utilized for PV systems. The population in the DGBCO is divided...
-
Response of cylindrical steel tank under stochastically generated non-uniform earthquake excitation
PublicationCylindrical steel tanks are very important structures in industrial facilities since their application is related to storing different types of products. Their safety and reliability have become a crucial issue because any damage may cause significant consequences, including ecological disaster. The most dangerous dynamic load acting on cylindrical steel tanks is related to earthquakes, especially that the seismic excitation may...
-
Synthesis, structure and properties of novel poly(hydroxyurethane)s obtained by non-isocyanate route
PublicationNon-isocyanate polyurethanes (NIPUs) can be synthesized by polyaddition of five-membered bis(cyclic carbonate)s and primary diamines. NIPUs are an alternative for the commonly used (in the form of foams, elastomers, coatings or fibers) in the industry polyurethanes obtained using toxic and moisture sensitive diisocyanates, polyols and low-molecular weight chain extenders. The main aim of this work was to synthesize non-isocyanate...
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088569751]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088563951]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088562991]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088567711]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088565141]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [3300730069456521]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088562471]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.