Filters
total: 2718
filtered: 366
-
Catalog
- Publications 2098 available results
- Journals 32 available results
- Publishing Houses 1 available results
- People 77 available results
- Inventions 3 available results
- Projects 4 available results
- e-Learning Courses 61 available results
- Events 28 available results
- Open Research Data 414 available results
Chosen catalog filters
Search results for: circulating tank
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Simulation of ship turning circle test for ballast and full load conditions
Open Research DataThe data show the results of the turning circle spiral test for the simplified ship model, taking into account two states of loading: ballast and full load. During the circulation test, the manoeuvrability of the vessel is tested.
-
Vident-real: an intra-oral video dataset for multi-task learning
Open Research DataWe introduce Vident-real, a large dataset of 100 video sequences of intra-oral scenes from real conservative dental treatments performed at the Medical University of Gdańsk, Poland. The dataset can be used for multi-task learning methods including:
-
Number of bank branches per million inhabitants in EU countries 2015
Open Research DataAccording to the data presented, over the year (2016-2017), the network of bank branches in Poland decreased by over half a thousand (currently the total number of traditional bank branches, excluding partner branches, amounts to nearly 6 thousand). It is worth noting, however, that the number of bank branches per million inhabitants is the highest...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Vident-lab: a dataset for multi-task video processing of phantom dental scenes
Open Research DataWe introduce a new, asymmetrically annotated dataset of natural teeth in phantom scenes for multi-task video processing: restoration, teeth segmentation, and inter-frame homography estimation. Pairs of frames were acquired with a beam splitter. The dataset constitutes a low-quality frame, its high-quality counterpart, a teeth segmentation mask, and...
-
Ship model resistance - KCS
Open Research DataShip model instantaneous resistance, velocity, pitch and heave measured data for a KCS built and tested in the towing tank of the Faculty of Mechanical Engineering and Ship Technology of Gdansk University of Technology under regular head waves.
-
Costs of privatization of the banking sector in Poland in 1997-2000
Open Research DataOn June 14, 1996, a special law was passed on the merger and grouping of certain banks in the form of joint-stock companies. Pursuant to these regulations, the PeKaO S.A. banking group was established, which was the only entity of this type established in this way. Additionally, by the end of 1996, four out of nine regional banks were sold, i.e. Wielkopolski...
-
Number of individual clients in Polish banks (10 largest entities) in 2017
Open Research DataAccording to the data of the National Bank of Poland, in 2017 Polish banks served 49 million customers (of which 45.5 million were retail customers). The largest number of individual clients was served by PKO Bank Polski - nearly 9.5 million, the second was Bank Pekao - 5.4 million, and the third place in the list of ING Bank Śląski - 4.6 million. A...
-
Number of active debit cards issued to individual customers (2017)
Open Research DataAt the end of the fourth quarter of 2017, financial institutions (including non-banking ones, e.g. SKOK) serviced 25.8 million debit cards (excluding credit card data) of individual clients. This means an increase by 1.3 million cards compared to the same period in 2016. The largest number of cards was issued and serviced by Bank PKO BP - 6.81 million,...
-
Changes in the number of commercial banks in 1992-2004
Open Research DataAs the data shows, it can be concluded that the number of banks in Poland is small. The main reason for the declining number of banks is bank acquisitions by foreign investors or bank consolidation. To a lesser extent, this change resulted from negative factors such as bankruptcy or liquidation.
-
The number of individual clients who log in to the bank using internet banking at least once a month (2017)
Open Research DataTaking into account active users, i.e. those who have used Internet access at least once, the situation is a bit different. Out of 32.5 million people who have access to electronic banking, 14.7 million people worked at least once a month (data as at the end of 2017). It is worth noting, however, that in this group there was also an increase in the...
-
Revenues to the state budget from the sale of shares in state-owned banks in 1994-2000
Open Research DataOn June 14, 1996, a special law was passed on the merger and grouping of certain banks in the form of joint-stock companies. Pursuant to these regulations, the PeKaO S.A. banking group was established, which was the only entity of this type established in this way. Additionally, by the end of 1996, four out of nine regional banks were sold, i.e. Wielkopolski...
-
Changes in the ownership structure of the banking sector (percentage share) in 1995-2004
Open Research DataAnalyzing the data, one can observe a steadily declining share of the State Treasury in the shareholding structure of banks. In 1995, the state owned over 40% of bank assets (counting directly the share of the State Treasury and indirectly through enterprises organized under state legal persons). At the same time, it should be noted that the NBP is...
-
Number of active credit cards issued to individual customers (2017)
Open Research DataPolish banks serviced 6.04 million credit cards in 2017. This is a decrease by 121,000 year on year (comparing 2017 and 2016). The largest issuer of credit cards in the country is Bank PKO BP. In the third quarter of 2017, this institution had 847,000 credit cards. Bank Zachodni WBK is second (803,000) and CITI Handlowy is third (697,000).
-
Number of mobile banking users who log into the bank at least once a month from a mobile device (telephone or smartphone) - 2017
Open Research DataElectronic banking should be understood broadly. Therefore, taking into account also other channels, the number of users using mobile electronic devices (smartphone, tablet) should be mentioned. Also in this case, there was an increase in the number of people using this channel of access to their bank account. At the end of 2017, nearly 9 million people...
-
EEG data recorded in three mental states
Open Research DataElectroencephalographic (EEG) signals were acquired from 17 (14 males, 3 females) participants aged between 20 and 30 years.
-
Areas of updraft air motion from WRF model simulations.
Open Research DataPresented dataset is a part of numerical modelling study focusing on the analysis of sea ice floes size distribution (FSD) influence on the horizontal and vertical structure of convection in the atmosphere. The total area and spatial arrangement of the updrafts indicates that the FSD affects the total moisture content and the values of area averaged...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_004)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_005)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0010)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_002)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0012)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_008)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_003)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_007)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...