Filters
total: 397
filtered: 274
-
Catalog
Chosen catalog filters
Search results for: IMPLANTY ORTOPEDYCZNE
-
Rozwój materiałów tytanowych na implanty aloplastyczne = Development of Ti-based materials for alloplastic implants
PublicationThe article is aimed at demonstraiting the previous results and current research work in the area made by Advanced Biomaterials Research Group at the Faculty of Mechanical Engineering. The paper concentrated on the developement of Ti-based biomaterials with improved biocompatibility and bioactivity.
-
The degradation of metal implants
PublicationThe presence of metal implants in the human body causes some dangers, which result from introducing another object into organism. There may occur a biocorrosion, which causes different modifications of implant surface.
-
Degradation of metallic implants
PublicationPresence of metallic implants made of stainless steels, Co and Ti alloys is sometimes followed by some undesired allergic reactions and inflammatory processes and consequently the necessity of reimplantation.
-
Mechanical Properties of Implants
PublicationW pracy przedstawiono wyniki identyfikacji ortogonalnego modelu matematycznego czterech typów implantów stosowanych w laparoskopowym leczeniu przepukliny brzusznej.
-
3D Printing of Metallic Implants
PublicationThe fabrication of various elements, solid and open porous structures of stainless steel and Ti alloy is described. The process was started with the design of 3D models in CAD/CAM system. The 3D models were transformed into *.stl files and then the manufacturing process of the real structures by means of the selective laser melting with the SLM Realizer 100 3D printer was made. The paper shows the porous specimens made for possible...
-
Engineering Challenges in the Design of Cochlear Implants
PublicationHearing aids such as cochlear implants have been used by both adults and children for a long time. In addition, cochlear implants are used by patients who have severe hearing loss either by birth or after an accident. This paper aims to investigate the engineering challenges bounding the design of cochlear implants and present its possible solution...
-
In vivo degradation of short-term implants
PublicationStan powierzchni wywiera istotny wpływ na właściwości użytkowe implantu. Stawiane wymagania, zależą od funkcji jakie ma spełniać wszczep oraz rodzaju implantowanego materiału. W przypadku implantów krótkotrwałych wymagana jest przede wszystkim odpowiednia odporność korozyjna, nie powinno tworzyć się trwałe połączenie pomiędzy wszczepem a tkanką kostną.Wszystkie biomateriały ulegają degradacji. Ważne jest to, aby produkty tej degradacji...
-
Degradation of metal implants covered with silver
PublicationSilver was known for its antibacterial properties as long ago as in antiquity. The silver ions have ability to join the bacteria surface. Low density of silver ions Ag+ influence the protons through the bacteria surface, which results in total destruction of the cell. Antibacterial activity of silver remains in proportion with the density of silver ions Ag+ in the environment.
-
Bioactive polyurethanes applied as a surgical implants
PublicationSynthetic materials are applied in many branches of the industry, i.a. in medicine as a casing of apparatus, elements of artificial organs (hearts, blood vessels), catheters, wound healings, intra aortic balloons, mammary implants to mention but a few. Polymeric material used in such applications must be distinguished by a good biocompatybility. Since many years extensive research are employed to develop a new polymers that can...
-
Microstructural Analysis of Fractured Orthopedic Implants
Publication -
The mechanisms of degradation of titanium dental implants
PublicationTitanium dental implants show very good properties, unfortunately there are still issues regarding material wear due to corrosion, implant loosening, as well as biological factors—allergic reactions and inflammation leading to rejection of the implanted material. In order to avoid performing reimplantation operations, changes in the chemical composition and/or modifications of the surface layer of the materials are used. This research...
-
The problem of infections associated with implants – an overview
PublicationImplant-associated infections are serious and relatively common complication that leads to implant loss. The purpose of this paper is to gather knowledge about this issue. A literature review of the epidemiology, risk factors and pathogenesis of infections related to implants was carried out. This position collects data on commonly used implants and infections associated with them from various fields of medicine and contains classifications...
-
Conducting polymers for biodegradable metallic implants
PublicationNowadays permanent metallic cardiovascular stents are long-term implants. The long-time presence of such an implant in human body can cause overgrowth of tissue within the treated portion of the vessel, blockage of the circulatory system and many other clinical complications, such as thrombosis, prolonged physical irritations or chronic inflammation. Therefore, in recent years, there is an interest to create biodegradable metallic...
-
The biological reactions on the implant-organism border
PublicationMateriał przeznaczony do implantacji w tkanki żywego organizmu powinien być biozgodny i biofunkcjonalny. Jeśli tak nie jest, ciało reaguje stanem zapalnym. Reakcje zapalne mogą się objawiać np. odrywaniem się cząstek materiału z powierzchni implantu na skutek tarcia lub nacisku, lub wytworzeniem biofilmu na jego powierzchni.
-
Experimental Research of Implant-Fascia Connections
PublicationW pracy przedstawiono wyniki identyfikacji siły zrywającej połączenie implantu z powięzią wykonane z użyciem różnych typów łączników: zszywek lub szwów chirurgicznych. Rozważono pięć typów łączników i pięć typów implantów.
-
Metal implants in ostheosynthesis - construction solutions, materials and applications
PublicationThe aim of the article is to present two case studies on intramedullary nails. The research included the evaluation of the type of fracture and the analysis of microstructure, chemical composition and hardness of the implant material.
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Porous materials used as inserted bone implants
PublicationArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
New techniques assisting cochlear implants fitting.
PublicationW referacie przedstawiono metodę telemetrii odpowiedzi neuronalnej (SoE), którą zastosowano w celu oceny amplitudy sygnału, która będzie wywoływała percepcję słuchową poprzez pobudzenie elektrod implantu ślimakowego. Jest to obiektywna metoda wyznaczania skuteczności systemów implantów ślimakowych.
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublicationCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublicationTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
The influence of biological environment on the silver-coated implants
PublicationThis paper deals with implants covered with nanosilver
-
Powłoki na osnowie pierwiastkowego węgla przeznaczone na implanty tytanowe
PublicationRozprawa miała na celu modyfikację podłoża z tytanu II oraz stopu Ti13Nb13Zr poprzez osadzenie elektroforetyczne (EPD) powłok na bazie wielościennych nanorurek węglowych (MWCNTs) z dodatkami wielkości nanometrycznej, przeznaczonych na pokrycia trzpieni endoprotez stawu biodrowego. Przygotowano trzy rodzaje powłok MWCNTs: z dodatkiem nanomiedzi (MWCNTs/Cu), nanosrebra (MWCNTs/Ag) oraz tlenku tytanu (MWCNTs/TiO2), osadzone w procesie...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Reactions on the surface of the implant under the influence of biofilm
PublicationThe contact of a biomaterial with the biological environment in in vitro and in vivo tests leads to the production of a particular ecosystem in which the active roles perform both, the material surface and the extracellular matrix protein forming a biofilm. Proteins affect cell and bacteria adhesion processes, biological activity of cells and activation of inflammatory response.The knowledge of the reaction mechanisms active on...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Wytwarzanie i modyfikacja powierzchni porowatych struktur tytanowych przeznaczonych na implanty
PublicationCelem pracy było wytworzenie stopu Ti-13Nb-13Zr z wykorzystaniem technologii selektywnego topienia laserowego (SLM) oraz jego biofunkcjonalizacja za pomocą utleniania mikrołukowego (MAO), a następnie określenie wpływu parametrów procesowych na właściwości otrzymanych materiałów pod kątem ich zastosowania na implanty. Oceniono wpływ napięcia, natężenia i czasu procesu MAO przeprowadzanego w elektrolicie zawierającym wapń i fosfor...
-
Porous biomaterial for orthopaedic implants based on titanium alloy
PublicationTytan i jego stopy są szeroko stosowane jako biomateriały dla zastosowań ortopedycznych. Badania związane z ich najlepszą odpornością na korozję i ścieranie, biozgodnością i bioaktywnością są stale prowadzone. Obecne badania koncentrują się również na projektowaniu i produkcji materiałów porowatych w oparciu o stopy np. Ti-13Nb-13Zr, które mogą być stosowane do wytwarzania implantów. Jedną z najbardziej efektywnych metod wytwarzania...
-
The influence of biological environment on the appearance of silver-coated implants
PublicationDespite antibiotics preventive treatment before and after implantation, risk of infection is real. The infections at the implant surface developein a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with silver layer come into use. The paper presents the research results in biological environment on vein and orthopaedicimplants covered with...
-
Characteristics of orthopaedic implants damage and mechanisms of its initiation
Publication -
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
The reactions occuring on the implant as a result of contact with human tissue
PublicationObecnosc implantu w ciele czlowieka powoduje liczne, czesto nieprzewidywalne skutki. Powodem takiej sytuacji jest duza roznorodnosc interakcji materialu medycznego z kontaktujaca sie z nim tkanka. Stwierdzenie to dotyczy glownie oddzialywan i skutkow zachodzacych na poziomie molekularnym w poszczegolnych komorkach kontaktujacej sie tkanki.
-
Allergy to implant components: chromium, nickiel, cobalt and titanium
PublicationImplant jest kompozycja roznych pierwiastkow: niklu, chromu, kobaltu, tytanu, molibdenu i wanadu. Pierwiastki te moga doprowadzic do alergii, egzemy i obluzowania implantu.
-
Behaviour of Fascia-Implant Structure under the Impulse Pressure
PublicationW pracy przedstawiono badania eksperymentalne wykonane dla modeli zaoperowanych przepuklin brzusznych poddanych impulsowemu działaniu ciśnienia, analogicznego do kaszlu pooperacyjnego. Zbudowano 57 modeli zgodnie ze sztuką oparacji laparoskopowej, z użyciem powiezi świńskiej, pięciu typów implantów i pięciu rodzajów łączników. Opisano otrzymane wyniki wskazując na mocniejsze i słabsze rozwiązania operacyjne.
-
Zastosowanie próby implant do oceny spawalności stali
PublicationPraca dotyczy oceny spawalności stali o podwyższonej i wysokiej wytrzymałości w aspekcie eksperymentalnego określania skłonności do tworzenia pęknięć zimnych. W artykule opisano metodykę określania wrażliwości na pękanie próbą implant. Przedstawiono również proponowane w literaturze i autorskie sposoby opracowywania i przedstawiania wyników badań rozpatrywaną metodą i ich interpretacji.
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublicationResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublicationObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublicationThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
The allergic and irritating reactions to metallic implants with trauma - orthopaedic patients
PublicationThe article presents the analysis of clinical operation complications after the treatment of long bones by mean of ostheosynthesis with the use of metal implants and endoprothesoplastic of hip joints.
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublicationThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublicationThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Trudności podczas modelowania próby implant w programie Ansys.
PublicationW artykule przedstawiono trudności związane ze stworzeniem modelu próby implant w programie Ansys. Określono również trudności związane z przypisaniem odpowiednim strefom połączenia spawanego własności mechanicznych.
-
Mechanical model of fascia-implant structure. Finite element simulation.
PublicationPraca dotyczy modelowania i symulacji syntetycznych implantów chirurgicznych stosowanych w leczeniu przepulin brzusznych metodą laparoskowpową. Prponowane są modele matematyczne a ich prawidłowość weryfikowana jest na podstawie badań doświadczalnych zachowania się modeli fizycznych wszczepionych implantów pod wpływem obciążeń wynikających z fizjologii człowieka. Nakreślona jest metodologia oceny trwałości połączenia siatki chirurgicznej...
-
Investigation on Filaments for 3D Printing of Nasal Septum Cartilage Implant
PublicationSeptoplasty is a widely used method in treating deviated septum. Although it is successfully implemented, there are problems with excessive bleeding, septal perforation, or infections. The use of anatomically shaped implants could help overcome these problems. This paper focuses on assessing the possibility of the usage of a nasal septum cartilage implant 3D printed from various market-available filaments. Five different types...
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublicationThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Nanotubular Oxide Layer Formed on Helix Surfaces of Dental Screw Implants
PublicationSurface modification is used to extend the life of implants. To increase the corrosion resistance and improve the biocompatibility of metal implant materials, oxidation of the Ti-13Nb- 13Zr titanium alloy was used. The samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of...
-
Are Titania Photocatalysts and Titanium Implants Safe? Review on the Toxicity of Titanium Compounds
Publication -
Enhancing middle ear implants: Study of biocompatible materials with hydroxyapatite coating
PublicationIn this manuscript, the application of hydroxyapatite coatings to total ossicular reconstruction prostheses (TORPs) using finite element modeling simulations was investigated to enhance the biocompatibility and mechanical performance of these prosthetic devices for middle ear implants. We focused on evaluating biocompatible materials, particularly polyetheretherketone (PEEK) and titanium, by analyzing their mechanical behavior...