Filters
total: 3230
-
Catalog
- Publications 2113 available results
- Journals 6 available results
- Conferences 5 available results
- People 18 available results
- Inventions 9 available results
- Projects 4 available results
- Research Equipment 1 available results
- e-Learning Courses 46 available results
- Events 1 available results
- Open Research Data 1027 available results
displaying 1000 best results Help
Search results for: MICROSTRIP COMPONENTS
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Voiceless Stop Consonant Modelling and Synthesis Framework Based on MISO Dynamic System
PublicationA voiceless stop consonant phoneme modelling and synthesis framework based on a phoneme modelling in low-frequency range and high-frequency range separately is proposed. The phoneme signal is decomposed into the sums of simpler basic components and described as the output of a linear multiple-input and single-output (MISO) system. The impulse response of each channel is a third order quasi-polynomial. Using this framework, the...
-
Using phase of short-term Fourier transform for evaluation of spectrogram performance
PublicationThe concept of spectrogram performance evaluation which exploits information on phase of short-term Fourier transform (STFT) is presented. A spectrograph which is time-frequency analyzing tool, is compared to a filter bank that demultiplexes a signal. Local group delay (LGD) and channelized instantaneous frequency (CIF) is obtained for each filtered component signal. In presented solution the performance is evaluated using so-called...
-
Colon, unspecified - Female, 85 - Tissue image [3300730069402361]
Open Research DataThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Checkpoints that regulate balanced biosynthesis of lipopolysaccharide and its essentiality in Escherichia coli
PublicationThe outer membrane (OM) of Gram-negative bacteria, such as Escherichia coli, is essential for their viability. Lipopolysaccharide (LPS) constitutes the major component of OM, providing the permeability barrier, and a tight balance exists between LPS and phospholipids amounts as both of these essential components use a common metabolic precursor. Hence, checkpoints are in place, right from the regulation of the first committed step...
-
Broadband Compact Single-Layer Magic-T Junction with Separation of DC Signals between All Ports
PublicationA novel structure for a four-port microstrip magic-T junction is presented. The device is composed of microstrip and slotline circuits etched onto two sides of a dielectric substrate. The device is extremely compact and occupies an area more than three times smaller than similar structures recently reported in the literature. The novelty of the device lies in the use of microstrip/slotline transitions for both input ports: summation...
-
Polska leksykografia terminologiczna z komponentem rosyjskim z dziedziny nauk prawnych. Bibliografia słowników za lata 1803–2014, [Polish terminological lexicography in the field of legal science including a Russian component. A bibliography of dictionaries published between 1803–2014]
Publication -
Janusz Datta prof. dr hab. inż.
PeopleIn 1988, Janusz Datta finished his studies at the Gdańsk University of Technology (GUT), Faculty of Chemistry. Since then he has been employed at the Faculty of Chemistry in the Department of Polymer Technology. During the first six years of employement he was worked as a scientist. In this period, he travelled extensively to ZACHEM company located in Bydgoszcz to gain practical experience related to chemical processing. In 1994,...
-
Wilms tumor - Male, 11 - Tissue image [5210730031825091]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [7040347232569211]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031823021]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031829301]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031822081]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824921]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826611]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [704024710495891]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031821481]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824591]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826241]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827511]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031823601]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [521073003182701]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031825701]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826781]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031821141]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031828861]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824721]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824291]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827961]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
SELECTION OF DIAGNOSTIC FUNCTIONS IN A WHEELED TRACTOR
PublicationIn a classical approach to damage diagnosis, the technical condition of an analyzed machine is identified based on the measured symptoms, such as performance, thermal state or vibration parameters. In wheeled tractor the fundamental importance has monitoring and diagnostics during exploitation concerning technical inspection and fault element localizations. The main functions of a diagnostic system are: monitoring tractor components...
-
Rapid EM-Driven Design of Compact RF Circuits By Means of Nested Space Mapping
PublicationA methodology for rapid design of RF circuits constituted by compact microstrip resonant-cells (CMRCs) is presented. Our approach exploits nested space mapping (NSM) technology, where the inner SM layer is used to correct the equivalent circuit model at the CMRC level, whereas the outer layer enhances the coarse model of the entire structure under design. We demonstrate that NSM dramatically improves performance of surrogate-based...
-
Slow-wave resonant structures in branch-line coupler miniaturization: a case study
PublicationA case study of novel slow-wave resonant structures dedicated to efficient microstrip branch-line coupler size reduction has been presented. A compact 3-dB branch-line coupler has been designed to mimic the performance of its conventional counterpart, simultaneously demonstrating a substantial 88% surface area reduction. The vital usefulness of the approach in the process of microstrip line abbreviation has been experimentally...
-
Fast Simulation-Driven Design of a Planar UWB Dipole Antenna with an Integrated Balun
PublicationThe paper presents a design of an ultra-wideband (UWB) antenna with an integrated balun. A fully planar balun interfacing the microstrip input of the structure to the coplanar stripline (CPS) input of the dipole antenna is introduced. The electromagnetic (EM) model of the structure includes the dipole, the balun, and the microstrip input to account for interactions over the UWB band. The EM model is adjusted for low reflection...
-
Doubly miniaturized rat-race hybrid coupler
PublicationTwo complementary miniaturization techniques have beenapplied to reduce the size of a rat-race hybrid coupler: (i) conventional microstrip sections have been replaced with their diminished lowimpedance counterparts as the first step of size reduction and (ii) novel fractal-shaped compact microstrip resonant cells dedicated to efficiently shorten low-impedance transmission line segments have been implemented as the second step of...
-
Spectrum Sensing Based on Hybrid Spectrum Handoff in Cognitive Radio Networks
PublicationThe rapid advancement of wireless communication combined with insufficient spectrum exploitation opens the door for the expansion of novel wireless services. Cognitive radio network (CRN) technology makes it possible to periodically access the open spectrum bands, which in turn improves the effectiveness of CRNs. Spectrum sensing (SS), which allows unauthorized users to locate open spectrum bands, plays a fundamental part in CRNs....
-
Design of Microwave-Based Angular Displacement Sensor
PublicationThis letter presents a novel microwave-based rotation sensor having a wide dynamic range to detect and measure the angular displacement in terms of the change in resonant frequency. The proposed sensor is based on the microstrip technology, where a rotor comprised of a complementary splitring resonator (CSRR) placed on the ground plane of the microstrip line is free to rotate around its axis. The mechanical rotation of CSRR determines...
-
System subwencjonowania jednostek samorządu terytorialnego w Polsce: dysfunkcje i pożądane kierunki racjonalizacji
PublicationMonografia poświęcona jest problematyce racjonalizacji subwencjonowania samorządu terytorialnego w Polsce. Jej głównym celem jest określenie roli i znaczenia subwencji w systemie finansowym jednostek samorządu terytorialnego. Za dysfunkcje w największym stopniu zniekształcające system subwencjonowania uznano: ― brak powiązania globalnej kwoty subwencji ogólnej ze składowymi budżetu państwa, ― pomijanie, przy ocenie potencjału...
-
Inverse modeling for fast design optimization of small-size rat-race couplers incorporating compact cells
PublicationIn the paper, a framework for computationally-efficient design optimization of compact rat-race couplers (RRCs) is discussed. A class of hybrid RRCs with variable operating conditions is investigated, whose size reduction is obtained by replacing ordinary transmission lines with compact microstrip resonant cells (CMRCs). Our approach employs a bottom-up design strategy leading to the development of compact RRCs through rapid design...
-
RF Input-Quasi-Reflectionless Dispersive-Delay Structures Based on Complementary-Diplexer Circuits
PublicationA class of RF dispersive-delay structures (DDSs) with input-quasi-reflectionless behavior is reported. It is based on the exploitation of complementary-diplexer circuit networks, in which the out-of-band RF-input-power echoes reflected by the main bandpass-filter-(BPF)-type channel are dissipated by the resistively-terminated auxiliary bandstop-filter-(BSF)-type channel. Specifically, it is shown that the influence of the absorptive...
-
Near Field Coupled Wireless Microwave Sensor
PublicationThis paper presents a wireless planar microwave sensor operating at industrial scientific and medical (ISM) frequency for the detection of dielectric materials. The microwave sensor consists of a reader (ground defected microstrip coupled line) and a passive tag where a complementary split-ring resonator (CSRR) is made on the commercially available copper-foil. The CSRR is a peel-off type tag that is excited using the near field...
-
Development of the System Assurance Reference Model for Generating Modular Assurance Cases
PublicationAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Larger assurance cases are usually divided into modules to manage the complexity and distribute the work. Each of the modules is developed to address specific goals allocated to the specific objects i.e. components of the...
-
Wilms tumor - Male, 11 - Tissue image [5210730031822361]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031829941]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827931]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031828571]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031828281]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Design of a Planar UWB Dipole Antenna with an Integrated Balun Using Surrogate-Based Optimization
PublicationA design of an ultra-wideband (UWB) antenna with an integrated balun is presented. A fully planar balun configuration interfacing the microstrip input of the structure to the coplanar stripline (CPS) input of the dipole antenna is introduced. The electromagnetic (EM) model of the structure of interest includes the dipole, the balun, and the microstrip input to account for coupling and radiation effects over the UWB band. The EM...
-
Model of distributed learning objects repository for a heterogenic internet environment
PublicationW artykule wprowadzono pojęcie komponentu edukacyjnego jako rozszerzenie obiektu edukacyjnego o elementy zachowania (metody). Zaproponowane podejście jest zgodne z paradygmatem obiektowym. W oparciu o komponent edukacyjny zaprojektowano model budowy repozytorium materiałów edukacyjnych. Model ten jest oparty o usługi sieciowe i rejestry UDDI. Komponent edukacyjny oraz model repozytorium mogą znaleźć zastosowanie w konstrukcji zbiorów...
-
On Decision-Making Strategies for Improved-Reliability Size Reduction of Microwave Passives: Intermittent Correction of Equality Constraints and Adaptive Handling of Inequality Constraints
PublicationDesign optimization of passive microwave components is an intricate process, especially if the primary objective is a reduction of the physical size of the structure. The latter has become an important design consideration for a growing number of modern applications (mobile communications, wearable/implantable devices, internet of things), where miniaturization is imperative due to a limited space allocated for the electronic circuitry....
-
Rapid and Reliable Re-Design of Miniaturized Microwave Passives by Means of Concurrent Parameter Scaling and Intermittent Local Tuning
PublicationRe-design of microwave passive components for the assumed operating frequencies or substrate parameters is an important yet a tedious process. It requires simultaneous tuning of relevant circuit variables, often over broad ranges thereof, to ensure satisfactory performance of the system. If the operating conditions at the available design are distant from the intended ones, local optimization is typically insufficient, whereas...