displaying 1000 best results Help
Search results for: RESTORING VOLTAGE
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublicationThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublicationIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublicationSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Current-Voltage Characteristics of the Composites Based on Epoxy Resin and Carbon Nanotubes
Publication -
Effect of contactless hybrid current limiter on voltage dips in power system.
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Control of a wind power generator in case of voltage sags in power network
PublicationW artykule poruszono problem związany ze sposobem sterowania generatorem elektrowni wiatrowej w przypadku wystąpienia po stronie sieci zapadów napięcia.Jako generator wykorzystano maszynę dwustronnie zasilaną której stojan podłączono bezpośrednio do sieci natomiast wirnik zasilano poprzez kaskadę przekształtników. Wystąpienie spadku lub zapadu napięcia sieci w przypadku pracy tego typu generatora może doprowadzić do uszkodzenia...
-
Critical evaluation of resonaut gc voltage link inventures for electrical drives.
PublicationPrzedstawiono wyniki modelowania i symulacji falowników z centralnym obwodem rezonansowym dla zastosowań w napędzie elektrycznym. Porównano struktury ukladów z rezonansowym równoległym obwodem pośredniczącym o ograniczonej wartości szczytowej i uasi-rezonansowych. Dla potrzeb projektowania tych układów, wobec przeciwstawnych funkcji celu dokonano ich wielokrytycznej oceny.
-
Design of synchronous generator voltage regulator based on h control theory
PublicationThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Simulation of influence of the air gap asymmetryon voltage waveforms of a synchronous machine
PublicationResults of simulation of a synchronous generator with the air gap asymmetry characterised by eccentricity are presented in the paper. The Lagrange's energy method has been used in derivation of the model equations. Analysis of influence of the air gap asymmetry on characteristics of self and mutual inductances of windings, as well as analysis of induced voltage waveforms as a function of the air gap asymmetry have been performed....
-
Self-Tuning Dead-Time Compensation Method for Voltage-Source Inverters
PublicationPrzedstawiono nową, kompleksową metodę kompensacji zniekształceń napięcia wyjściowego falownika z modulacją szerokości impulsów. Proponowana metoda umożliwia automatyczne dopasowanie parametrów charakterystyki kompensacyjnej do aktualnej konfiguracji falownika i obciążenia, np. po zmianie przewodu łączącego falownik z obciążeniem. Adaptacja do nowych warunków polega na dostrajaniu wartości parametrów zależności opisującej napięcie...
-
Effect of contactless hybrid current limiter on voltage dips in power system
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Design of synchronous generator voltage regulator based on H control theory
PublicationSystemy dużej mocy są z reguły systemami o dużej nieliniowości. Wynika to z dynamiki takiego obiektu jak również jego konfiguracji itd. Istnieje wiele metod umożliwiających sterowanie czy testowanie zaprojektowanych generatorów. W artykule analizowana jest metoda projektowania regulatora napięcia w oparciu o H. Wyniki symulacji są zadowalające, ponieważ tak zaprojektowany regulator lepiej tłumi kołysania elektromechaniczne niż...
-
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublicationZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
Concept of Wireless Low-Voltage DC Socket for the Residential House Application
PublicationThe proposed research is devoted to the comprehensive theoretical and experimental study of the concept of the wireless low power dc socket for residential applications. The main goal of this work is to provide safe dc source for residential customers at power level which is enough in order to supply all typical appliances without power factor correctors. Such types of devices can be already connected to the dc grid and decoupled...
-
A versatile analog CMOS cell: voltage - buffer /current - conveyor/ multiplier
PublicationW pracy przedstawiono koncepcję uniwersalnej komórki analogowej przeznaczonej dla programowalnych układów analogowych (FPAA). Komórka może pełnić funkcję bufora napięciowego, konwjora prądowego lub mnożnika analogowego. Układ przesymulowano w technologii CMOS 2 ćm.
-
The photocurrent quantum efficiency dependence on the applied voltage in organic solar cells
PublicationWe demonstrate that our recently reported model (Szmytkowski 2007 J. Phys. D: Appl. Phys. 40 3352) of the photocurrent quantum efficiency in organic semiconductors explains the external quantum efficiency dependence on the electric field in organic solar cells. This effect can be explained by taking into account that the photogeneration of charge carriers occurs via the electron-hole pair dissociation and the space charge effects...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublicationThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublicationIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System
PublicationThis paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublicationThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Storing thermal energy from solar collectors for the needs of a detached house
PublicationThis work evaluates the possibility of meeting a single familu household's need for hot water and heat year round, using solar collectors as the sole energy sourse. The main flaw of energetic systems based on solar energy is that the energy supply is usually insufficient in winter, when it is most needed. This work is going to show thatm for a house surface of 150 m2 and base dimension of 10x10m, it is possible to supply sufficient...
-
The role and scope of architectural and conservation research procedures in the process of restoring the splendour of an architectural monument created after 1945 on the example of the Suburban Railway Station in Gdynia
PublicationModern Movement buildings, despite their relatively recent construction, are sometimes affected by radical transformations of layout and form. The railway stations being one of the most important public buildings in the city are a special group of them. Due to long-term and intensive use they may bear the signs of exploitation of parts of its substance and have secondary transformations disharmony with the building. The subject...
-
The Application of Kernel Density Estimation for Aided the Process of Locating Sources of Voltage Fluctuations
Publication -
Trace of Flicker Sources by Using Non-Parametric Statistical Analysis of Voltage Changes
Publication -
AM Modulation Signal Estimation Allowing Further Research on Sources of Voltage Fluctuations
Publication -
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublicationHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublicationThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublicationIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Modification of current-voltage characteristics of planar organic systems by nm-thick interlayer
PublicationEffect of nm-thick interlayer of copper phthalocyanine (CuPc) or perylene dye (MePTCDI) on current-voltage characteristics of planar organic systems is discussed in the work. The MePTCDI layer strongly limits injection of holes from ITO into CuPc, while CuPc limits injection of electrons from ITO into MePTCDI. In the systems with CuPc/MePTCDI heterojunction an explicit photovoltaic effect occurs.
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublicationThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublicationThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Structural Investigations and Determination of Current and Voltage Characteristics in Htsc 2G SF12050 Tapes
Publication -
Output-capacitorless low-dropout regulator using a cascoded flipped voltage follower
PublicationPrzedstawiono udoskonaloną konfigurację wtórnika napięciowego w odwróconej konfiguracji oraz jej zastosowanie w regulatorze o małym spadku napięcia. W pracy przedstawiono teoretyczną analizę podstawowych parametrów wtórnika oraz regulatora napięcia. Ponadto przedstawiono wyniki pomiarów parametrów prototypowego układu scalonego wykonanego z użyciem technologii CMOS 0.35 um. Uzyskane wyniki porównano z rezultatami uzyskanymi w innych...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublicationThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
Temperature effect on the current-voltage characteristic fill factor for the silicon solar cells
PublicationW pracy przedstawiono badania wpływu temperatury pracy krzemowych ogniw fotowoltaicznych na wartość współczynnika wypełnienia charakterystyki prądowo- napięciowej (FF). Efekty dyfuzyjne w obszarze złącza oraz rekombinacja nośników ładunku ograniczają wartość współczynnika wypełnienia charakterystyki. Spadek tej wartości wynika głównie ze wzrostu wartości rezystancji szeregowej rs. Na rezystancję szeregową składają się: opór emitera...
-
Protection against electric shock in electrical installations with low voltage generating sets
PublicationW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Computer simulation of current voltage response of elektrocatalytic sensor.Optoelectronic and Electronic Sensors V.
PublicationW pracy przedstawiono wyniki symulacji komputerowej działania czujnika elektrokatalitycznego. Do badań wykorzystano program D. Gossera opierający się na metodzie różnic skończonych.
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublicationThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublicationThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.