Filters
total: 2696
displaying 1000 best results Help
Search results for: carpentry joint
-
Numerical analysis of the carpentry joints applied in the traditional wooden structures
PublicationThe paper concerns the numerical analysis of the carpentry joints made from spruce wood. The material parameters of the wood have been calculated on the basis of nine independent material constants (an orthotropic material). The contact zone between the individual elements of the connection has been determined using Contact Tables in the MSC.Marc software. Five types of carpentry joints have been analyzed. The main aim of the research...
-
NUMERICAL MODELLING AND EXPERIMENTATION OF HISTORICAL CARPENTRY CORNER LOG JOINTS
PublicationThe main purpose of this research is to determine the stress distributions on the contact surfaces between the logs of the historical carpentry corner joints. The additional purpose is to compare the stress distribution for four different boundary conditions in the case of dry and wet pine wood. The paper presents the results of numerical analysis of the shortcorner dovetail connection and the saddle notch corner joint, which are...
-
Experimental and computational study on mechanical behaviour of carpentry corner log joints
PublicationThis work concerns experimental and numerical research on carpentry joints used in historic wooden buildings in southeastern Poland and western Ukraine. These structures are mainly sacred buildings, and the types of corner log joints characteristic of this region are primarily saddle-notch and dovetail joints; thus, these two types of joints were analysed in this study. The modelling of historic timber structures is a complex...
-
Historical carpentry corner log joints—Numerical analysis within stochastic framework
PublicationThe paper presents the results of numerical analysis performed on historical, traditional carpentry corner logjoints of two basic topologies: the short-corner dovetail connection and the saddle notch connection. These types of carpentry joints are commonly used in currently preserved objects of wooden architecture. All connections have been modelled in pinewood, which has been defined in the Finite Element software MSC.Marc/Mentat...
-
Intelligent artificial joint and regeneration problems in articular joints
PublicationPraca przedstawia zasady działania inteligentnych sztucznych stawów biodrowych człowieka oraz problemy regeneracji chrząstek stawowych w stawach naturalnych człowieka. Postuluje się wagę podjętych badań w powyższym problemie.Zwrócono uwagę na problemy związane ze sterowaniem własności sztucznych stawów biodrowych oraz z identyfikacją impulsów przekazywanych naturalnym połączeniom stawowym człowieka.
-
Annals of Joint
Journals -
Joints
Journals -
Bone & Joint Research
Journals -
Bone & Joint Journal
Journals -
Joint Commission: The Source
Journals -
JOINT BONE SPINE
Journals -
Bone & Joint Open
Journals -
Joint Commission perspectives. Joint Commission on Accreditation of Healthcare Organizations
Journals -
Journal of Fixed Point Theory and Applications
Journals -
POINT VETERINAIRE
Journals -
Point of Care
Journals -
Bulletin of the Hospital for Joint Diseases
Journals -
Journal of Arthroscopy and Joint Surgery
Journals -
Joint Diseases and Related Surgery
Journals -
Journal of Bone and Joint Infection
Journals -
Underwater welded joint properties investigation
PublicationPrzeprowadzono badania mikro- i makroskopowe złączy spawanych typu implant wykonanych pod wodą metodą lokalnej komory suchej. Wyniki badań świadczą o tym, że w SWC badanych złączy tworzą się kruche struktury hartownicze, które są odpowiedzialne za zwiększoną skłonność stali o podwyższonej wytrzymałości do tworzenia pęknieć zimnych. Analiza rozkładów twardości złączy implant również potwierdza istnienie szkodliwego wpływu środowiska...
-
Endometriosis and the Temporomandibular Joint—Preliminary Observations
Publication -
Impact of interface heterogeneity on joint fracture
PublicationThe effects of heterogeneities (weak zones in particular) inadhesive joints and their importance on overall fracture propertiesare relatively unknown, but doubtlessly they may be crucial inmany applications. Using a model heterogeneous adhesive bond,represented by a given mixture of regions of strong and weakadhesion, we have studied the influence of interface variabilityon overall fracture energy (global energy release rate)....
-
Temporomandibular Joint Injections and Lavage: An Overview of Reviews
Publication -
Joint time–frequency analysis of electrochemical noise
Publication -
Modeling knee joint endoprosthesis mode of deformation
Publication -
Human hip joint lubrication for permeable cartilage
PublicationPraca przedstawia pewien model obliczeń wartości sił tarcia zapisany w ortogonalnych sferycznych i innych krzywoliniowych układach współrzędnych dla hydrodynamicznego, niesymetrycznego przepływu cieczy synowialnej o własnościach nienewtonowskich i zmiennej lepkości w szczelinie stawu biodrowego człowieka z uwzględnieniem zmian losowych. Według informacji autora tak przedstawiony model nie był do tej pory rozpatrywany w pracach...
-
Strength assessment of a version of joint of sandwich panels
PublicationW pracy przedstawiono propozycję optymalizacji wariantu połączenia doczołowego stalowych paneli typu ''sandwich''. Przedstawiono wyniki analizy numerycznej rozkładów naprężeń dla wielu wariantów geometrii proponowanego połączenia.
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublicationBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
3D Computer Model of the Hip Joint Cartilage
PublicationThis paper presents 3D computer model of the hip joint cartilage in the ANSYS program. Model is made on the basis of anatomy and collected data on the material constants of bone and cartilage components. Analysis and comparison of biochemical model, viscoelastic and molecular mixed - aggregation serves to facilitate the creation of the next model of reality, which could be used in the design of joint prostheses. The correctness...
-
Analysis of wave propagation in a bolted steel joint
PublicationThe paper presents results of numerical and experimental investigations of elastic wave propagation in a bolted single-lap joint. The research was carried out for both symmetric and antisymmetric Lamb wave modes. In experimental studies the PZT transducers were used to excite and register wave propagation signals. The controlled value of the torque during measurements was ensured by the use of high precision torque wrenches. Numerical...
-
The validation process of truss model with joint eccentricities
PublicationNowadays, due to the technological reasons in modern lightweight steel trusses, fabricated from cold-formed sections, positive eccentricities appear in the truss nodes, to induce additional forces truss chords. In order to account for the real load-carrying capacity of truss node area the steel structure research was conducted in scale 1:1. As a result of experimental research, the forms of deformation and strains of the walls...
-
TRUSS JOINT WITH POSITIVE ECCENTRICITY EXPERIMENTAL RESEARCH
PublicationDue to the technological reasons in modern lightweight steel trusses, fabricated from cold- formed sections, positive eccentricities appear in the truss nodes what induce additional forces in the truss chords. To account for the real load-carrying capacity of truss node area the steel structure research in scale 1:1 were conducted. The experiments consisted of two parts: preliminary and proper one, when conclusions from...
-
Pressure and capacity in hip joint afte injury.
PublicationPraca przedstawia zarys analitycznego wyprowadzenia równania Reynoldsa do wyznaczania rozkładów wartości ciśnienia w szczelinie sferycznego stawu biodrowego człowieka po udarze w nieustalonym ruchu impulsywnym. W wyprowadzonym modelu uwzględniono lepkosprężyste właściwości cieczy synowialnej oraz stochastyczny opis chropowatości chrząstki stawowej. Numeryczne wartości ciśnienia wyznaczono w programie Mathcad 2001 przy wykorzystaniu...
-
On the joint time-frequency characteristics of chemical oscillations
PublicationZaprezentowano rezultaty analizy czasowo-częstotliwościowej rejestrów potencjałowych oscylacyjnej reakcji Biełousowa-Żabotyńskiego (BŻ). Wybraną reprezentację czasowo-częstotliwościową w postaci algorytmu STFT zastosowano do analizy typowych przebiegów reakcji BŻ, prowadzonej w układzie zamkniętym. Zaprezentowano spektrogramy STFT ukazujące czasowo-częstotliwościową strukturę oscylacji regularnych, mieszanych i chaotycznych. Na...
-
Propagation analysis of the point-to-point radio links operating in the band
PublicationThe theoretical possibilities of utilizing the EHF-band frequencies for point-to-point short range communications have been discussed. The most important factors that affect propagation attenuation in this band have been briefly described, as well as relevant mathematical formulas that allow for numerical analysis of these phenomena. After that, a research have been carried out in which the authors have analyzed propagation losses...
-
Point to point control of fractional differential linear control systems
Publication -
Archives of Bone and Joint Surgery-ABJS
Journals -
Nephrology @ Point of Care
Journals -
Lamb wave propagation in a single lap adhesive joint
Publication -
Bolted Joint Monitoring Using the Elastic Wave Propagation
Publication -
Possibilities for assesment of the angular distortion in Welded T-joint
PublicationSpawanie jest podstawową techniką łączenia elementów konstrukcji kadłuba statku. Procesowi temu towarzyszą odkształcenia spawalnicze, co przysparza dużo problemów wykonawczych. W pracy przedstawiono wpływ przewymiarowania spoiny pachwinowej na wielkość kątowych odkształceń złącza. Dokonano porównania wartości określonych na podstawie inżynierskich hipotez z wynikami otrzymanymi podczas prób laboratoryjnych.
-
Experimental investigation of joint with positive eccentricity in CFS truss
PublicationDue to technological restrictions, in the case of trusses made of CFS open cross-sections, positive eccentricities in the truss joints have become very frequent. Therefore studies concerning the load-bearing capacity of truss joints with positive eccentricity were undertaken. It was assumed that the resistance of cold-formed steel (CFS) open cross-section truss joints located on compression chords and with positive eccentricity...
-
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublicationObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
Lamb wave propagation in a single lap adhesive joint
PublicationThe aim of the paper is the analysis of Lamb wave propagation in adhesive joints. The research was performed on a single lap adhesive joint of two steel plates. Two types of joints, namely an intact and with defect were considered. In experimental investigations the condition assessment of the joint was performed with the use of antisymmetric Lamb waves excited by a plate piezo actuators and measured by a laser vibrometer. Numeri-cal...
-
A Finer Point on Vision
PublicationAs an IES Member, I look forward to each issue of LD+A and read them with great interest as they are often very informative. To my surprise, the Research article (May 2019, p. 76) has an error which should be corrected.
-
Joint optimization of anycast and unicast flows in survivable optical networks
PublicationZnane z literatury dotychczasowe prace związane z ochroną ruchu przed awarią elementów sieci dotyczą transmisji typu unicast (jeden-do-jednego). Niniejszy artykuł jest pierwszym prezentującym rozwiązanie jednoczesnej ochrony transmisji anycast (jeden-do-jednego-z-wielu) oraz transmisji unicast. Proponowane podejście wykorzystuje model ochrony ścieżki (ang. path protection). Zagadnienie zostało sformułowane w postaci odpowiedniego...
-
Is Ultrasonography an Effective Method for Diagnosing Degenerative Changes in the Temporomandibular Joint?
Publication -
Umbilical and Placental Derivatives in Temporomandibular Joint Treatment: A Systematic Review
Publication -
Numerical Simulations of Laser and Hybrid S700MC T-Joint Welding
Publication