Nie znaleźliśmy wyników w zadanych kryteriach!
Ale mamy wyniki w innych katalogach.Filtry
wszystkich: 7050
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MAXIMUM RESPONSE TIME
-
Application of Maximum-Length Sequences to impulse response measurement of hydroacoustic communications systems
PublikacjaThere is a growing interest in digital transmission of telemetry data on ultrasonic waves. The dependence of signal attenuation on squared frequency, specific to the hy-droacoustic systems, induces problems that do not exist in monochromatic, narrowband radio communications systems. For adapting the transmission parameters to current propagation conditions, a precise knowledge of instantaneous changes of channel performances is...
-
Maximum vertex occupation time and inert fugitive: recontamination does help [online]
PublikacjaRozważamy problem przeszukania danego grafu prostego G w celu przechwycenia niewidocznego i leniwego uciekiniera. Parametrem optymalizacyjnym, który minimalizujemy jest maksymalny czas (liczba tur strategii przeszukiwania), podczas których wierzchołek może być strzeżony (okupowany przez strażnika). Strategia monotoniczna to taka, która nie dopuszcza sytuacji, w której uciekinier dociera do wierzchołka, który wcześniej został oczyszczony....
-
Non-causal final impulse response filters for the maximum return from capital markets
PublikacjaW artykule rozważa się strategię operacji na rynkach kapitałowych, która polega na kupowaniu lub sprzedawaniu instrumentu finansowego, kiedy sygnał wyjściowy nie-przyczynowego filtru o skończonej odpowiedzi impulsowej osiąga odpowiednio minimum lub maksimum. Celem artykułu jest wyznaczenie "najlepszego" nie-przyczynowego filtru o skończonej odpowiedzi impulsowej (FIR), który zapewnia maksymalną stopę zwrotu z rynku przy użyciu...
-
CMOS Low-Dropout Regulator With Improved Time Response
PublikacjaPrzedstawiono nową konfigurację regulatora o obniżonym spadku napięcia, w którym wykorzystano stopień wyjściowy z równoległym sprzężeniem napięciowym. Dzięki obniżonej rezystancji wyjściowej stopnia, uzyskano poprawę odpowiedzi impulsowej regulatora na szybką zmianę prądu wyjściowego.
-
On time-dependent nonlinear dynamic response of micro-elastic solids
PublikacjaA new approach to the mechanical response of micro-mechanic problems is presented using the modified couple stress theory. This model captured micro-turns due to micro-particles' rotations which could be essential for microstructural materials and/or at small scales. In a micro media based on the small rotations, sub-particles can also turn except the whole domain rotation. However, this framework is competent for a static medium....
-
Autonomous Sensory Meridian Response (ASMR): The time perception approach
Publikacja -
ADAPTIVE IDENTIFICATION OF TIME-VARYING IMPULSE RESPONSE OF UNDERWATER ACOUSTIC COMMUNICATION CHANNEL
PublikacjaThe transmission properties of underwater acoustic communication channel can change dynamically due to the movement of acoustic system transmitter and receiver or underwater objects reflecting transmitted signal. The time-varying impulse response measurement and estimation are necessary to match the physical layer of data transmission to instantaneous channel propagation conditions. Using the correlative measurement method, impulse...
-
Influence of Analyte Flow Rate on Signal and Response Time of the Amperometric Gas Sensor with Nafion Membrane
PublikacjaW publikacji przedstawiono rezultaty badań nad wpływem zmian objętościowego natężenia przepływu gazu na sygnał i czas odpowiedzi prototypowego czujnika ditlenku siarki z membraną nafionową. Porównywano właściwości czujników różniących się materiałem elektrody pracującej oraz składem roztworu elektrolitu wewnętrznego. Zastosowano elektrody pracujące wykonane z napylonych próżniowo na powierzchnię membrany nafionowej złota i platyny....
-
DETERMINING THE TIME CONSTANT USING TWO METHODS AND DEFINING THE THERMOCOUPLE RESPONSE TO SINE EXCITATION OF GAS TEMPERATURE
PublikacjaThis paper describes the two methods of determining the time constant of type K thermocouple, for two construction solutions: the exposed weld and the mantle fillet weld. This is an important parameter indicating the response time of the thermocouple on the recorded signal. The first method consists of determining the value of τ in the way of numerical simulation of heat exchange between the thermocouple and the current of gas...
-
Using Statistical Methods to Estimate The Worst Case Response Time of Network Software Running on Indeterministic Hardware Platforms
PublikacjaIn this paper we investigate whether the statistical Worst Case Execution Time (WCET) estimation methods devised for embedded platforms can be successfully applied to find the Worst Case Response Time (WCRT) of a network application running on a complex hardware platform such as a contemporary commercial off-the-shelf (COTS) system. Establishing easy-to-use timing validation techniques is crucial for real-time applications and...