Filtry
wszystkich: 6766
wybranych: 1609
-
Katalog
- Publikacje 4896 wyników po odfiltrowaniu
- Czasopisma 40 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 78 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 33 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 1708 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: THREE ELECTRODE MEASUREMENT
-
Three series of measurement of spring force in relation to deflection of disc springs assembled in X configuration.
Dane BadawczeAttached data consist of three series of conducted measurement of disc springs package characteristic. The characteristic describes relation between spring force and deflection of the package. First column of each serie present axial deflection of the package, while second columns contain recorded spring force. Object of research contained six disc...
-
Results of EIS measuremnts and DRT analysis of SrTi0.30Fe0.70O3-d oxygen electrode at 800 °C and 1% oxygen partial pressure by using three R-CPE fiting elements
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 1% of oxygen partial pressure. EIS and DRT spectra of simmulated three R-CPE elements from equivalent circuit,...
-
The electrochemical response to BDD electrode functionalization with CD147 receptor
Dane BadawczeThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with CD147 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with ACE2 receptor
Dane BadawczeThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with ACE2 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with IgG2B receptor
Dane BadawczeThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with IgG2B receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Dane BadawczeThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
The electrochemical response to Au electrode modification steps towards viral electrochemical immunosensor preparation
Dane BadawczeThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the Au electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration, with...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
The Mott-Schottky characteristics of microwave pulsed-plasma polymerized allylamine by DEIS analysis
Dane BadawczeThe dataset contains the results obtained for the Mott-Schottky analysis of the microwave pulsed-plasma polymerized allylamine using the multifrequency perturbation signal with Dynamic Electrochemical Impedance Spectroscopy (DEIS) technique. The results were obtained using the perturbation composed of the elementary signals with a frequency range between...
-
SEM micrographs of 3D printed CB-PLA samples topography after microwave treatment
Dane BadawczeThis dataset contains the electrochemical studies on microwave-activated carbon-black doped polylactic acid 3D printed electrodes.
-
Depth chemical profile in a CeIr3 sample
Dane BadawczeThe polycrystalline sample of CeIr3 used in the present studies was synthesized by arc-melting cerium (4N) and iridium (3N5) in an arc furnace on a water-cooled copper hearth using a tungsten electrode under a high purity argon atmosphere. A piece of zirconium was used as an oxygen getter. First, a button of Ir was prepared by arc-melting the iridium...
-
The cyclic voltammetry studies of CB-PLA electrode after surface activation by electrolysis in 1M NaOH
Dane BadawczeThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M NaOH solution. The studies were performed after treatment at an anodic overpotential of 1V, found to be optimal for surface activation. The measurements were carried out with cyclic voltammetry (CV) under different...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion
Dane BadawczeThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K (72h digestion period). Different enzyme concentrations were evaluated: 0.2, 0.4, 0.6 and 0.8 mg/ml. The studies were performed before surface activation, during and...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion with different times and concentrations
Dane BadawczeThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K. DIfferent proteinase K concentrations and digestion times were evaluated, as described in subfolder names. The studies were performed before surface activation, during...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 700 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 700 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 800 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 800 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Cyclic polarization studies of Mg corrosion in alkaline environment
Dane BadawczeThe dataset contains the cyclic polarization studies of Mg (99.99%) in NaOH electrolyte at different pH values: 10, 11 and 12 aiming at understanding of Mg(OH)2 passive layer formation mechanism and conditions. The electrochemical studies were carried out in a three electrode setup, with Pt mesh as the counter electrode and Ag|AgCl as the reference...
-
The hydrogen evolution reaction (HER) performance of some FTO/MoS2/SnO2 electrodes
Dane BadawczeTo demonstrate the electrochemical performance of the FTO/MoS2/SnO2 for HER (hydrogen evolution reaction), the LSV (linear sweep voltammetry) was performed. The polarization curves of the obtained composite were measured in 1 M H2SO4 at room temperature with a scan rate 10 mV/s. For comparison, the LSV for the FTO, pure MoS2 and Pt plate electrode were...
-
The influence of chitosan hydrogel coating on different redox probes kinetics
Dane BadawczeThis dataset contains cyclic voltammetry studies of three redox probes: 1 mM K3[Fe(CN)6], [K4Fe(CN)6], C12H14FeO2, and [Ru(NH3)6]Cl2 dissolved in 0.1 M KCl or PBS as the primary electrolyte. The studies are made for glassy carbon electrode (GC) and glassy carbon electrode covered with thin chitosan hydrogel membrane (C2A2). Cyclic voltammograms were...
-
The corrosion studies of 3,4,5-trihydroxybenzoic acid as an effective corrosion inhibitor of low alloy steel
Dane BadawczeThe dataset contains the electrochemical studies evaluating if gallic acid is a corrosion inhibitor for low alloy steel. Three measurements were carried out each case; corrosion potential (label ecorr), electrochemical impedance spectroscopy (label eis) and cyclic polarization (label cp). The measurements were carried out in sodium chloride, acidified...
-
The electrochemical studies of CB-PLA surface activation by electrolysis in 1M NaOH
Dane BadawczeThe dataset contains the electrochemical studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by electrolysis in 1M NaOH solution under cycling polarization with different anodic or cathodic overpotentials (data in different subfolders). The file names contain the exact...
-
Cyclic voltammetry curves for FTO/PANI:WO3 nanocomposite
Dane BadawczeThis dataset contains the results of kinetic electrochemical studies, carried out with cyclic voltammetry (CV) of FTO/PANI:WO3 nanocomposite at various scan rates: 10, 20, 50, 75, 100 and 200 mV/s. The electrolyte was 1M H2SO4 solution. The measurements were performed in a three electrode setup, and with Ag|AgCl|3M KCl as the reference electrode and...
-
The photocatalytic activity of MoS2 electrodes under sunlight illumination
Dane BadawczeThis dataset contains the results of the photocatalytic activities of the MoS2 and MoS2 modified by SnO2 were assessed through the photocatalytic reduction of Cr6+ under the sunlight illumination. In the experiment, 20 mg of the catalyst was distributed in the K2Cr2O7 aqueous solution (50 mL, 100 mg•L-1). The mixed solution was stirred for 30 min to...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Surface activation by cyclic polarization in 1M HCl and its effects on the electrochemical response of CB-PLA 3D printed electrodes
Dane BadawczeThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M HCl solution. The studies were performed after treatment at different polarization ranges, as labeled in subfolder names. For each electrode the consecutive studies describe different samples, as labeled in subfolders:...
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...