Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 4-8h.
Dane BadawczeWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 4-8h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h.
Dane BadawczeWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h. High frequency burst recording.
Dane BadawczeWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. High frequency burst recording.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21,...
-
Electrical conductivity of the (Ce0.80Gd0.20)O1.90 pellet at different oxygen partial pressures
Dane BadawczeThis dataset contains results electrical conductivity measurements of dense (Ce0.80Gd0.20)O1.90 (CGO-20) pellet. DC electrical conductivity measurements of CGO-20 were performed by the Van der Pauw method between 900 °C and 450 °C with 50 °C step. Studies were performed at different oxygen partial pressures (100%, 20% and 1%) under humidified (~4...
-
Long-term measurements from a photovoltaic power plant and meteorological stations at the Laboratory LINTE^2 of Gdańsk University of Technology
Dane Badawcze1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E). 2) The measurements have been collected from a photovoltaic power plant located on the roof of the laboratory, having total capacity...
-
Electrical conductivity of the Sr0.86Ti0.65Fe0.35O3-d pellet at different oxygen partial pressures
Dane BadawczeThis dataset contains results electrical conductivity measurements of dense Sr0.86Ti0.65Fe0.35O3-d (STF35) pellet. DC electrical conductivity measurements of STF35 were performed by the Van der Pauw method. Studies were performed at different oxygen partial pressures (20%, 1% and 0.1%) under humidified (~4 vol%) gas flow rate of 50 ml min -1.
-
Electrical conductivity of the SrTi1-xFexO3-d pellets at 20% pO2
Dane BadawczeThis dataset contains results electrical conductivity measurements of dense SrTi1-xFexO3-d (x=0.35, 0.50, 0.70) pellets. DC electrical conductivity measurements were performed by the Van der Pauw method between 900 °C and 200 °C. Studies were performed at 20% of oxygen partial pressure under humidified (~4 vol%) gas flow rate of 50 ml min -1.
-
Low temperature electrical conductivity of the SrFeO3-d pellet
Dane BadawczeThis dataset contains results of low temperature electrical conductivity measurements of dense SrFeO3-d (SFO) pellet. DC electrical conductivity measurements of SFO were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas flow rate of 40...
-
Low temperature electrical conductivity of the SrTi0.65Fe0.35O3-d pellet
Dane BadawczeThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.65Fe0.35O3-d (STF35) pellet. DC electrical conductivity measurements of STF35 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.30Fe0.70O3-d pellet
Dane BadawczeThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.30Fe0.70O3-d (STF70) pellet. DC electrical conductivity measurements of STF70 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.50Fe0.50O3-d pellet
Dane BadawczeThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.50Fe0.50O3-d (STF50) pellet. DC electrical conductivity measurements of STF50 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.10Fe0.90O3-d pellet
Dane BadawczeThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.10Fe0.90O3-d (STF90) pellet. DC electrical conductivity measurements of STF90 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
X-ray diffraction spectra of nitrogen-doped carbon in hybrid materials containing praseodymium oxide
Dane BadawczeX-ray powder diffraction patterns of samples were carried out by Philips X’Pert diffractometer, which was radiated by graphite monochromatized Cu Kα (l equal 1.540598). The operating voltage was maintained at 40 kV, the current was maintained at 30 mA and analyzed in the range from 20° to 90°. The data presented confirmed the presence of the PrBSCF...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Investigation of low-temperature cracks on selected national roads and motorways in Poland 2020
Dane BadawczeThe dataset contains video investigation and records of 68 road sections in various parts of Poland. Videos were recorded with the use of two cameras: 1) mounted in front of measurement vehicle, which was focused on overall view of road and 2) which was focused on pavement surface. The records are categorized according to the ID of the section given...
-
Experimental investigation of the weight averaging of pulse frequency modulated sensor output signal
Dane BadawczeThe research aims to practically verify the results of theoretical analysis and simulations of the efficiency of weight averaging of pulse frequency modulated signal. For this purpose, a suitable test stand was built, and the control software in the LabVIEW environment was prepared. Then, a series of experiments were carried out to process and analyze...
-
Audible noise in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
MODALITY corpus - SPEAKER 29 - COMMANDS C1
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 29 - SEQUENCE S1
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
The power spectral density of audible noise and electric disturbances in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
MODALITY corpus - SPEAKER 21 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 01 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 10 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 03 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 17 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 27 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 33 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 32 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 35 - COMMANDS C5
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
MODALITY corpus - SPEAKER 23 - SEQUENCE S1
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 23 - COMMANDS C1
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 09 - SEQUENCE S1
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...
-
MODALITY corpus - SPEAKER 09 - COMMANDS C1
Dane BadawczeThe MODALITY corpus is one of the multimodal database of word recordings in English. It consists of over 30 hours of multimodal recordings. The database contains high-resolution, high-framerate stereoscopic video streams and audio signals obtained from a microphone array and a laptop microphone. The corpus can be employed to develop an AVSR system,...