Use of optical skin phantoms for calibration of dermatological lasers
PublikacjaA wide range of dermatological diseases can be efficiently treated using laser heating. Nevertheless, before the new laser is introduced into clinical practice, its parameters and ability to interact with human skin have to be carefully examined. In order to do that optical skin phantoms can be used. Such phantoms closely imitate the scattering and absorption properties of real human skin tissue along with its thermal properties,...
-
Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy
PublikacjaSkin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to...
-
Investigation of photothermolysis therapy of human skin diseases using optical phantoms
PublikacjaDermatological diseases, such as neurofibroma (Recklinghausen disease) or hemangiomas can be efficiently treated using photothermolysis from laser irradiation. We have utilized a developed 975 nm fiber diode laser as a low-cost alternative over common Nd:YAG lasers. This paper describes the investigations of interaction of 975 nm diode laser radiation-pulses with optical skin phantoms which were designed and manufactured in our...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublikacjaExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublikacjaThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
Colored Tattoo Ink Screening Method with Optical Tissue Phantoms and Raman Spectroscopy
PublikacjaDue to the increasing popularity of tattoos among the general population, to ensure their safety and quality, there is a need to develop reliable and rapid methods for the analysis of the composition of tattoo inks, both in the ink itself and in already existing tattoos. This paper presents the possibility of using Raman spectroscopy to examine tattoo inks in biological materials. We have developed optical tissue phantoms mimicking...
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublikacjaIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Porous Phantoms Mimicking Tissues—Investigation of Optical Parameters Stability Over Time
PublikacjaOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods, while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom in optical system. Measurements were performed in multiple series with an interval...
-
Model of optical phantoms thermal response upon irradiation with 975 nm dermatological laser
PublikacjaWe have developed a numerical model describing the optical and thermal behavior of optical tissue phantoms upon laser irradiation. According to our previous studies, the phantoms can be used as substitute of real skin from the optical, as well as thermal point of view. However, the thermal parameters are not entirely similar to those of real tissues thus there is a need to develop mathematical model, describing the thermal and...