Filtry
wszystkich: 181
wybranych: 176
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: fault detection
-
Nonlinear model of a synchronous generator for analysis of more electric aircraft power systems
PublikacjaA nonlinear model for studying a variable-speed synchronous generator (SG) in more electric aircraft (MEA) power system has been developed. The saturation effects of the SG magnetic circuit have been considered. The model has been implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SG model. The model exhibit a network with the same number of external terminals/ports...
-
Nonlinear Model of Synchronous Generator for Autonomous Electrical Power Systems Analysis
PublikacjaThis paper presents the nonlinear lookup table model for synchronous generator (SG) analysis. The saturation effects of the SG magnetic circuit have been considered. The saturated characteristic of the SG magnetic circuit are based on the open circuit saturation curve for magnetizing inductances. The model has been implemented into the Synopsys/Saber software using the MAST modelling language. To implement the no-load voltage characteristic...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublikacjaThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
EE-ISAC—Practical Cybersecurity Solution for the Energy Sector
PublikacjaA recent survey of cybersecurity assessment methods proposed by the scientific community revealed that their practical adoption constitutes a great challenge. Further research that aimed at identifying the reasons for that situation demonstrated that several factors influence the applicability, including the documentation level of detail, the availability of supporting tools, and the continuity of support. This paper presents the...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublikacjaElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
A Novel Approach to Fully Nonlinear Mathematical Modeling of Tectonic Plates
PublikacjaThe motion of the Earth's layers due to internal pressures is simulated in this research with an efficient mathematical model. The Earth, which revolves around its axis of rotation and is under internal pressure, will change the shape and displacement of the internal layers and tectonic plates. Applied mathematical models are based on a new approach to shell theory involving both two and three-dimensional approaches. It is the...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublikacjaThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
A distributed system for conducting chess games in parallel
PublikacjaThis paper proposes a distributed and scalable cloud based system designed to play chess games in parallel. Games can be played between chess engines alone or between clusters created by combined chess engines. The system has a built-in mechanism that compares engines, based on Elo ranking which finally presents the strength of each tested approach. If an approach needs more computational power, the design of the system allows...
-
BeesyBees: A mobile agent-based middleware for a reliable and secure execution of service-based workflow applications in BeesyCluster
PublikacjaIntegrating distributed services into workflows comes with its own set of challenges, including security, coordination, fault tolerance and optimisation of execution time. This paper presents an architecture and implementation - nicknamed BeesyBees - that allows distributed execution of workflow applications in BeesyCluster using agents. BeesyCluster is a middleware that allows users to access distributed resources as well as publish...
-
ON EGNOS MONITORING IN LOCAL CONDITIONS
PublikacjaAny SBAS system should deliver to the user corrections to pseudoranges as well as information about the system integrity. In theory, as soon as the system is permanently monitored by RIMS stations, it is impossible to deliver the fault information to the user. However many observations shows that accuracy of EGNOS service in the same time are different in different places, which shows the influence of local conditions on them....
-
Enhancing seismic performance of steel buildings having semi-rigid connection with infill masonry walls considering soil type effects
PublikacjaUnpreventable constructional defects are the main issues in the case of steel Moment-Resisting Frames (MRFs) that mostly occur in the rigidities of beam-to-column connections. The present article aims to investigate the effects of different rigidities of structures and to propose Infill Masonry Walls (IMWs) as retrofitting strategy for the steel damaged buildings. A fault or failure to meet a certain consideration of the soil type...
-
Diagnostic system of wheeled tractors detecting four defect's categories
PublikacjaIn a classical approach to damage diagnosis, the technical condition of an analyzed machine is identified based on the measured symptoms, such as performance, thermal state or vibration parameters. In wheeled tractor the fundamental importance has monitoring and diagnostics during exploitation concerning technical inspection and fault element localizations. The main functions of a diagnostic system are: monitoring tractor components...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Trends in Locally Balanced Energy Systems without the Use of Fossil Fuels: A Review
PublikacjaIn recent years, the idea of the operation of energy systems (power systems, heating systems) has changed significantly. This paper is an overview of locally balanced energy systems without the use of fossil fuels. The paper justifies the concept of local energy balancing in a new energy system that does not use fossil fuels (coal, natural gas, and crude oil), based on European Union guidelines and formal documents as well as the...
-
Quantitative Risk Assessment in Construction Disputes Based on Machine Learning Tools
PublikacjaA high monetary value of the construction projects is one of the reasons of frequent disputes between a general contractor (GC) and a client. A construction site is a unique, one-time, and single-product factory with many parties involved and dependent on each other. The organizational dependencies and their complexity make any fault or mistake propagate and influence the final result (delays, cost overruns). The constant will...
-
Probabilistic assessment of SMRFs with infill masonry walls incorporating nonlinear soil-structure interaction
PublikacjaInfill Masonry Walls (IMWs) are used in the perimeter of a building to separate the inner and outer space. IMWs may affect the lateral behavior of buildings, while they are different from those partition walls that separate two inner spaces. This study focused on the seismic vulnerability assessment of Steel Moment-Resisting Frames (SMRFs) assuming different placement of IMWs incorporating nonlinear Soil-Structure Interaction (SSI)....
-
Refinement of the Hardening Soil model within the small strain range
PublikacjaThe popularity of the elasto-plastic Hardening Soil (HS) model is based on simple parameter identification from standard testing and empirical formulas. The HS model is implemented in many commercial FE codes designed to analyse geotechnical problems. In its basic version, the stress–strain behaviour within the elastic range is subject to the hypoelastic power law, which assures the barotropy of the elastic stiffness. However,...
-
Machine learning-based seismic response and performance assessment of reinforced concrete buildings
PublikacjaComplexity and unpredictability nature of earthquakes makes them unique external loads that there is no unique formula used for the prediction of seismic responses. Hence, this research aims to implement the most well-known Machine Learning (ML) methods in Python software to propose a prediction model for seismic response and performance assessment of Reinforced Concrete Moment-Resisting Frames (RC MRFs). To prepare 92,400 data...
-
Monolithic vs. Microservice Architecture: A Performance and Scalability Evaluation
PublikacjaContext. Since its proclamation in 2012, microservices-based architecture has gained widespread popularity due to its advantages, such as improved availability, fault tolerance, and horizontal scalability, as well as greater software development agility. Motivation. Yet, refactoring a monolith to microservices by smaller businesses and expecting that the migration will bring benefits similar to those reported by top global companies,...
-
Modelling and analysis of a synchronous generator in more electric aircraft power system using Synopsys/Saber simulator = Modelowanie i analiza generatora synchronicznego w systemie elektroenergetycznym nowoczesnego samolotu. Zastosowanie symulatora Synopsys/Saber
PublikacjaStreszczenie angielskie: A model for studying synchronous machine (SM) dynamic behaviour in more electric aircraft (MEA) power system is developed and implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SM model. The elaborated model exhibit a network with the same number of external terminals/ports as the real SM, and represents its behaviour in terms of the electrical...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublikacjaPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublikacjaIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
Identification of defected sensors in an array of amperometric gas sensors
PublikacjaPurpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...
-
Sensorless Disturbance Detection for Five Phase Induction Motor with Third Harmonic Injection
PublikacjaThe paper presents a sensorless disturbance detection procedure that was done on a five phase induction motor with third harmonic injection. A test bench was developed where a three phase machine serves as disturbance generator of different frequencies. The control of the machines is based on multi scalar variables that ensures an independent control of the motor EMF and the rotor flux. For disturbance identification a speed observer...