Filtry
wszystkich: 2259
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: THE BEST SPINDLE SPEED
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Aggregated conducted interferences generated by group of asynchronous drives with deterministic and random modulation
PublikacjaThis paper addresses problems linked with electromagnetic interferences generated by group of three adjustable speed drives fed by frequency converters with deterministic and random modulation. Based on the experimental results it has been shown that decreasing of the conducted interferences in a case of random modulation is measuring phenomenon linked with selectivity of the EMI receiver.
-
Testbed for development and verification of hybrid localization systems
PublikacjaIn this paper a testbed for development and verification of hybrid localization systems is presented. It allows for systematic analysis of hybrid localization methods and speed up the development of new schemes. The proposed testbed platform is composed of subsystem for sequential data collection and testing infrastructure that can be used for investigating the localization mechanisms in controllable environment.
-
Magdalena Szuflita-Żurawska
OsobyMagdalena Szuflita-Żurawska jest kierownikiem Sekcji Informacji Naukowo-Technicznej na Politechnice Gdańskiej oraz Liderem Centrum Kompetencji Otwartej Nauki przy Bibliotece Politechniki Gdańskiej. Jej główne zainteresowania badawcze koncentrują się w obszarze komunikacji naukowej oraz otwartych danych badawczych, a także motywacji i produktywności naukowej. Jest odpowiedzialna między innymi za prowadzenie szkoleń dla pracowników...
-
Losses and energy efficiency of drive motors and systems
PublikacjaLosses and energy efficiency of every drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the machine or device driven by the motor, changing in the drive operating field. Speed and load of the motor decide of the instantaneous useful power of the motor and also in a differentiated way of kinds and values of losses occurring in the...
-
The effect of thermal modification on the quality of the milled surface of beech and pine wood
PublikacjaThe article deals with the effect of thermal modification on the quality of the created surface during milling on CNC milling cutters. The quality of the created surface is evaluated based on surface roughness, specifically its roughness parameter Ra. The observed surface is created by a shank cutter with a diameter of 20 mm and three cutting edges in a spiral at a standard speed of 18,000. min-1. The article compares thermally...
-
Losses and energy efficiency of drive motors and systems
PublikacjaLosses and energy efficiency of every drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the machine or device driven by the motor, changing in the drive operating field. Speed and load of the motor decide of the instantaneous useful power of the motor and also in a differentiated way of kinds and values of losses occurring in the...
-
(R,R)-1-Acetyl-1'-(2,4,6-trinitrophenyl)-2,2'-bipyrrolidine
Publikacja(R,R)-1-Acetyl-1'-(2,4,6-trinitrophenyl)-2,2'-bipyrrolidine has been synthesized and its rentgenostructure has been determined. The structure of the title molecule, C16H19N5O7, is mainly determined by the steric effect of a bulky 2,4,6-trinitrophenyl group attached to the N atom of a pyrrolidine ring. Both pyrrolidine rings adopt an envelope conformation, with one of the methylene C atoms as the flap in each case, and the N-C-C-N...
-
FLUID BED COATING OF MINITABLETS AND PELLETS WITH OPTIMIZATION OF THE PROCESS BASED ON TAGUCHI METHOD
PublikacjaSmall particles like pellets are coated in fluid bed systems. This method can be also feasible for minitablets but the selection of optimal process parameters is complicated. The aim of the research was to optimize the coating process for minitablets and to compare the conditions required for pellets. Minimum fluidization velocities (umf) for 2.0 and 2.5 mm minitablets and 0.7-0.8 mm or 1.0-1.25 mm pellets were determined experimentally....
-
Szacowanie estymaty menzurandu temperatury skóry człowieka podczas próby wysiłkowej
PublikacjaW artykule zaprezentowano wyniki pomiarów temperatury skóry człowieka podczas próby wysiłkowej. Ponieważ uzyskane wyniki nie podlegają rozkładowi normalnemu, wyznaczono wartości pięciu różnych estymatorów menzurandu. Otrzymane rezultaty wykazały, że w rozważanym przypadku najlepszy estymator menzurandu otrzymujemy z metody bootstrap, ponieważ charakteryzuje się on najmniejszym odchyleniem standardowym.
-
Energy losses in hydrostatic drive:Drive investigation method compatible with diagram of power increase opposite to the direction of power flow
PublikacjaEnergy losses and efficiency of drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the driven device, changing in the drive operating field. Speed and load decide of the useful power and, in differentiated way, of kinds and values of losses in the motor. But energy losses and efficiency of drive motors are evaluated as functions of...
-
Fracture in composite/aluminium joints of variable adhesive properties
PublikacjaA strain gauge technique recently developed with the wedge test, for estimating crack length and, thus, the fracture energy of structural adhesive bonding, has been employed on a system in which one adherend had two types of surface treatment. Simple polishing and polishing with subsequent sandblasting were the treatments used, with a distinct straight line, perpendicular to the sample edges, separating the two. Despite the clear-cut...
-
Appendix E
PublikacjaThe advance of variable speed drives systems (VSDs) engineering highlights the need of specific technical guidance provision by electrical machines and drives manufacturers, so that such applications can be properly designed to present advantages in terms of both energy efficiency and expenditure. This book presents problems and solutions related to inverter-fed electrical motors. Practically orientated, the book describes the...
-
Improving Output Performance of the Ultrasonic Multicell Piezoelectric Motor by Development the Multi-Rotor Structure
PublikacjaIn recent years, many researches have been carried out on piezoelectric multi-rotor structures. This paper describes the analysis, development and experimental process of an ultrasonic multi-cell piezoelectric motor using a multi-rotor structure. In this design, three independent cells have been integrated into a mechatronic system. Analytical model and finite element method are used for modal and dynamic analysis of the proposed...
-
Influence of friction stir welding technological parameters on the properties of the joints of selected aluminum alloys
PublikacjaThe purpose of this dissertation was to determine the effect of friction stir welding technological parameters on the properties of selected aluminum alloy joints, with consideration of the residual stresses and dislocation density in the joints. The goal of the present work was also to produce defect-free joints with high mechanical and electrochemical properties. In the dissertation, similar welds of AA6082 alloy and dissimilar...
-
Experimental Study of Silent Sonar
PublikacjaStealth is a frequent requirement in military applications and involves the use of devices whose signals are difficult to intercept or identify by the enemy. The silent sonar concept was studied and developed at the Department of Marine Electronic Systems of the Gdansk University of Technology. The work included a detailed theoretical analysis, computer simulations and some experimental research. The results of the theoretical...
-
Tyre rolling resistance and its influence on fuel consumption
PublikacjaRolling resistance of tyres is one of the major resistive forces acting on any wheeled vehicle. Unfortunately, it is also one of the forces very difficult to measure. It is estimated that in certain traffic conditions (like for example constant speed driving with slow or moderate speed) so called Rolling Resistance Impact Factor may be as high as 0.3. This means that reduction of rolling resistance by 50% would lead to 15% of energy...
-
Determination of the Theoretical and Actual Working Volume of a Hydraulic Motor—Part II (The Method Based on the Characteristics of Effective Absorbency of the Motor)
Publikacja: In this article, the second method of determination of the theoretical and actual working volume of a hydraulic motor is described. The proposed new method is based on the characteristics of effective absorbency of the motor. The effective absorbency has been defined as the ratio of flow rate in a motor to the rotational speed of the motor’s shaft. It has been shown that the effective absorbency is a nonlinear function of the...
-
Practical Eco-Driving Strategy for Suburban Electric Multiple Unit
PublikacjaIn this paper, a practical approach to velocity profile optimization for electric multiple unit was presented. The study focuses on a case of fast urban railway, which is a popular mean of transport across Tricity, Poland. Based on observations and measurements, a potential for improvement of energy efficiency by modifying the speed profile was recognized. In order to conduct necessary calculations, simulation model of railway...
-
Flow visualization and heat transfer investigations on the flat plate with streamwise pressure gradient
PublikacjaPaper presents experimental investigations results for film cooling on a flat plate. The main objective of the design is the streamwise pressure distribution on the flat plate as in the blade cascade. The transient and steady-state technique with liquid crystals for the surface temperature distribution with film cooling has been used in experiments in a low speed wind tunnel.
-
Karolina Zielińska-Dąbkowska dr inż. arch.
OsobyKarolina M. Zielinska-Dabkowska (dr inż. arch., Dipl.-Ing. Arch.[FH]) jest adiunktem na Wydziale Architektury Politechniki Gdańskiej. W roku 2002 ukończyła studia na Wydziale Architektury i Urbanistyki Politechniki Gdańskiej a w 2004 inżynierii architektonicznej na HAWK Hochschule für angewandte Wissenschaft und Kunst Hildesheim w Niemczech. Po studiach pracowała dla kilku firm o światowej renomie w Berlinie, Londynie, Nowym Jorku...
-
Emotion Recognition
Dane BadawczeThe films presented here were recorded using so-called high-speed camera Phantom Miro. To play the movie You need the special software which can be downloaded from the web site https://www.phantomhighspeed.com/resourcesandsupport/phantomresources/pccsoftware the details of the movie are available after starting the movie in the viewer in the description...