Filtry
wszystkich: 1405
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: nonlinear fiber optics
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Analysis of compressive forces in CFGFT cylindrical pillars and their coatings using laboratory tests and metric spaces
PublikacjaThe article discusses compressive forces tests in composite-concrete pillars with the use of laboratory active experiment including the factors and properties of materials which have a significant impact on the test results and their repeatability. A polymer composite based on glass fiber reinforced resin with different fiber beam angles (20, 55 and 85) was used as a buffer/coat of the pole. Due to the problems with direct comparison...
-
Joanna Janczewska prof. dr hab.
OsobyJoanna Janczewska odbyła studia wyższe magisterskie na kierunku Matematyka w latach 1994–1999 z wynikiem bardzo dobrym i uzyskała w 1999 roku tytuł magistra. W 2002 roku na Uniwersytecie Gdańskim uzyskała stopień naukowy doktora nauk matematycznych w zakresie matematyki. Promotorem w przewodzie doktorskim był dr hab. Andrzej Borysowicz, prof. UG. W październiku 2004 roku podjęła pracę na stanowisku adiunkta w Katedrze Algebry...
-
Annealing of indium tin oxide (ITO) coated optical fibers for optical and electrochemical sensing purposes
PublikacjaGlass and fiber structures with Indium Tin Oxide (ITO) coating were subjected to annealing in order to identify impact of the thermal treatment on their optical and electrochemical properties. It is shown that the annealing process significantly modifies optical properties and thickness of the films, which are crucial for performance of optical fiber sensors. Moreover, it visibly improves electrochemical activity of ITO on glass...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Tuning the extraction properties of ionogel-coated Solid-phase microextraction fibers based on the solvation properties of the ionic liquids
PublikacjaA silica-based network was used to immobilize ionic liquid-based ionogels and applied as a fiber coating forsolid-phase microextraction (SPME). The ionogels were prepared by a sol–gel process, using two ionic liquids,triethylsulfonium bis(trifluoromethylsulfonyl)imide ([Set3][TFSI]) and 1-butyl-1-methylpiperidinium bis(tri-fluoromethylsulfonyl)imide ([C4C1Pip][TFSI]), as well as their equimolar mixture. Methyltrimethoxysilane wasused...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Jaroslaw Spychala dr
OsobyOprócz bardzo dobrego wykształcenia osoba posiada również wieloletnie doświadczenie zawodowe, które jest poświadczeniem tego, że potrafi wykorzystać swoją wiedzę teoretyczną w praktycznych działaniach. Doświadczenie zawodowe jest bardzo bogate i rozbudowane. Ze względu na nabyte całkiem nowe umiejętności zwiększa się atrakcyjność doświadczonego pracownika. Są to między innymi kreatywne myślenie, zorientowanie na cel, odporność...
-
Solid Phase Micro-Extraction, a Versatile and Handy Tool in Environmental Trace Organic Analysis, Gets a New Class of Coatings, Polymeric Ionic Liquids
PublikacjaSolid phase microextraction (SPME) fundamentals, characteristics and application are described. The special stress is put on characteristics of sorbents used as SPME fiber coatings. Description of commercially available fibers and the present-day trends in development of new sorbents for SPME are given. Discussion is focused on possibility of application of ionic liquids (IL) and polymeric ionic liquids (PIL) as SPME fiber coatings....
-
Studies on applicability of new solid-phase microextraction and determination of short - chain monocarboxylic acids
PublikacjaA convenient approach to monitor the short-chain monocaroboksylic acids (SCAMs) in different samples is gas chromatography (GC) preceded by sample preparation based on solid-phase microextraction (SPME). The fiber with polar coatings were used to extract the SCAMs from headspace of liquid and solid samples. Recently polimeric ionic liquid (PIL) fiber coatings have been proposed to extract volatile organic compounds, minly polar...
-
The low coherence Fabry-Pérot interferometer with diamond and ZnO layers
PublikacjaThe authors present a fiber-optic Fabry-Pérot interferometer built with the application of diamond and zinc oxide (ZnO) thin layers. Thin ZnO films were deposited on the tip of a standard telecommunication single-mode optical fiber (SMF- 28) while the diamond layer was grown on the plate of silicon substrate. Investigated ZnO layers were fabricated by atomic layer deposition (ALD) and the diamond films were deposited using Microwave...
-
Silica-Based Ionogels: Nanoconfined Ionic Liquid-Rich Fibers for Headspace Solid-Phase Microextraction Coupled with Gas Chromatography–Barrier Discharge Ionization Detection
PublikacjaIn this work, hybrid silica-based materials with immobilized ionic liquids (ILs) were prepared by sol–gel technology and evaluated as solid-phase microextraction (SPME) fiber coatings. High loadings of the IL 1-methyl-3-butylimidazolium bis(trifluoromethylsulfonyl)imide ([C4MIM][TFSI]) were confined within the hybrid network. Coatings composition and morphology were evaluated using scanning electron microscopy and energy dispersive...
-
Marcin Kujawa dr hab. inż.
OsobyMarcin Kujawa ukończył studia na Wydziale Budownictwa Lądowego Politechniki Gdańskiej w 1999 roku, uzyskując stopień magistra inżyniera w specjalności mosty. Stopień naukowy doktora nauk technicznych w dziennie: budownictwo, pod kierunkiem profesora Czesława Szymczaka, uzyskał w 2007 roku na Wydziale Inżynierii Lądowej Politechniki Gdańskiej, broniąc pracę doktorską, pt.: Statyka i analiza wrażliwości rusztów zbudowanych z prętów...
-
Comparative analysis of switched reluctance motor control algorithms
PublikacjaПредмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...
-
Comparative analysis of switched reluctance motor control algorithms
PublikacjaПредмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...
-
Surface quality control of a thin SiN layer by optical measurements
PublikacjaFiber optic interferometers have a wide range of applications, including biological and chemical measurements. Nevertheless, in the case of a reflective interferometer setup, standard silver mirrors cannot be used in every measurement, due to their chemical activity. This work investigates the surface quality of a thin optical layer of silicon nitride (SiN), which can serve as an alternative material for silver mirrors. We present...
-
Application of wavelength division multiplexing in sensor networks
PublikacjaOver the past few years the need to acquire data on various parameters from a number of sensors grew. The need that led to the development of a network of sensors which enables simultaneous control and measurement in a wide range of applications. The aim of this article is to discuss a possibility of connecting a variety of sensors in a network that would utilize WDM technology. Wavelength Division Multiplexing is commonly used...
-
Anomalous diffraction approximation to the light scattering coefficient spectra of marine particles with power-law size distribution
Publikacja -
Acousto-optic interaction of a Gaussian laser beam with an ultrasonic wave of cylindrical symmetry
Publikacja -
Acousto-optic interaction with the use of cylindrical ultrasonic waves in the laser cavity
Publikacja -
Low-threshold lasing eigenmodes of an infinite periodic chain of quantum wires
Publikacja -
Periodicity-induced effects in the scattering and absorption of light by infinite and finite gratings of circular silver nanowires
Publikacja -
Finite-difference time-domain analyses of active cloaking for electrically-large objects
PublikacjaInvisibility cloaking devices constitute a unique and potentially disruptive technology, but only if they can work over broad bandwidths for electrically-large objects. So far, the only known scheme that allows for broadband scattering cancellation from an electrically-large object is based on an active implementation where electric and magnetic sources are deployed over a surface surrounding the object, but whose ‘switching on’...
-
A new conformal radiation boundary condition for high accuracy finite difference analysis of open waveguides
PublikacjaW publikacji zaprezentowano nowe warunki brzegowe przeznaczone dla precyzyjnej analizy otwartych prowadnic falowych metodą różnic skończonych. Praca zawiera również liczne przykłady zastosowania proponowanej techniki oraz porównanie otrzymanych rezultatów numerycznych z wynikami otrzymywanymi przy użyciu innych metod.
-
Spectral measurement of birefringence using particle swarm optimization analysis
PublikacjaThe measurement of birefringence is useful for the examination of both technical and biological objects. One of the main problems is that the polarization state of light in birefringent media changes periodically. Without the knowledge of the period number, the birefringence of a given medium cannot be determined reliably. We propose to analyse the spectrum of light in order to determine the birefringence. We use a Particle Swarm...
-
Analysis of microstructured optical fibers using compact macromodels
PublikacjaW niniejszym artykule zaproponowano nową technikę analizy światłowodów fotonicznych. Zaprezentowany algorytm jest kombinacją metody redukcji rzędu modelu oraz techniki dyskretnych rozwinięć funkcyjnych i pozwala w znaczącym stopniu zmniejszyć liczbę zmiennych (nawet do 85%), redukując (nawet 16 krotnie) czas symulacji.
-
External Validation Measures for Nested Clustering of Text Documents
PublikacjaAbstract. This article handles the problem of validating the results of nested (as opposed to "flat") clusterings. It shows that standard external validation indices used for partitioning clustering validation, like Rand statistics, Hubert Γ statistic or F-measure are not applicable in nested clustering cases. Additionally to the work, where F-measure was adopted to hierarchical classification as hF-measure, here some methods to...
-
Anna Brillowska-Dąbrowska dr hab. inż.
OsobyAnna Brillowska-Dąbrowska, urodzona w 1971 r. w Gdańsku, ukończyła w 1996 r. studia magisterskie na kierunku Biotechnologia, na Wydziale Chemicznym PG. Stopień doktora uzyskała po ukończeniu Studium Doktoranckiego przy Wydziale Chemicznym PG w 2001 r. W 2013 r. uzyskała stopień doktora habilitowanego. W 2004 r. została zatrudniona na stanowisku naukowiec w Statens Serum Institut w Danii w Jednostce Mikologii i Parazytologii. W...
-
The experimental research on the axially compressed CFFT columns
PublikacjaThe research objectives is to test the behaviour of the axially compressed glass fiber reinforced polymer tubes CFFT (concrete-filled FRP tube) withe the R-C core.
-
Evaluation of polycaprolactone as a new sorbent coating for determination of polar organic compounds in water samples using membrane–SPME
PublikacjaCommercially available solid-phase microextraction fibers used for isolation of polar analytes are based on the adsorption phenomenon. In consequence, typical limitations bonded with analytes displacement and matrix effects are very frequent. In the present study, alternative solution is described. Polycaprolactone (PCL) was used for the first time as sorbent to isolate polar organic compounds from water samples using the membrane–solid-phase...
-
Unusual streaming in chemically reacting gases
PublikacjaNonlinear stimulation of the vorticity mode caused by losses in the momentum of sound in the chemically reacting gas, is considered. The instantaneous dynamic equation which describes the nonlinear generation of the vorticity mode, is derived. It includes a quadratic nonlinear acoustic source. Both periodic and aperiodic sound may be considered as the origin of the vorticity flow. In the non-equilibrium regime of the chemical reaction,...