wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: generalized impedance matrix
-
Photoprotection and Antiaging Activity of Extracts from Honeybush (Cyclopia sp.)—In Vitro Wound Healing and Inhibition of the Skin Extracellular Matrix Enzymes: Tyrosinase, Collagenase, Elastase and Hyaluronidase
Publikacja -
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stanless steel
PublikacjaPraca prezentuje wyniki badań uzyskane z pomiarów techniką lokalnej spektroskopii impedancyjnej (LIS) wykonanych w trybie kontaktowym mikroskopii sił atomowych (AFM), które zostały przeprowadzone w lokalnych obszarach powierzchni ziarna austenitu i na granicy ziarna austenitu wysokostopowej stali austenitycznej AISI 304 poddanej procesowi uczulania oraz na próbkach odniesienia nie poddanych obróbce cieplnej.Badania LIS-AFM były...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stainless steel
Publikacja -
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
The effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution, impedance and microscopic studies
Dane BadawczeThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC. This dataset contains the results of electrochemical impedance spectroscopy (EIS) studies done on daily basis...
-
Preexisting High Expression of Matrix Metalloproteinase-2 in Tunica Media of Saphenous Vein Conduits Is Associated with Unfavorable Long-Term Outcomes after Coronary Artery Bypass Grafting
Publikacja -
Enzymatic cleavage of specific dipeptide conjugated with ferrocene as a flexible ultra-sensitive and fast voltammetric assay of matrix metalloproteinase-9 considered a prognostic cancer biomarker in plasma samples
Publikacja -
Effect of Porosity on the Thermo-Mechanical Behavior of Friction-Stir-Welded Spark-Plasma-Sintered Aluminum Matrix Composites with Bimodal Micro- and Nano-Sized Reinforcing Al2O3 Particles
PublikacjaThe thermo-mechanical behavior of nanosized Al2O3 particles reinforcing aluminum was analyzed in the present paper. The material was prepared by spark plasma sintering and friction stir welding. The thermal stresses affecting the composite behavior during welding were modeled through COMSOL MultiPhysics, and the results were validated by the analyses of the composites’ mechanical properties. The spark-plasma-sintered materials...
-
Grzegorz Lentka dr hab. inż.
OsobyGrzegorz Lentka uzyskał tytuł magistra inżyniera w roku 1996 na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej w zakresie systemów pomiarowych. Stopień doktora nauk technicznych uzyskał w roku 2003, a doktora habilitowanego w 2014. Obecnie zatrudniony jest w Katedrze Metrologii i Optoelektroniki na stanowisku profesora PG. W ramach prowadzonej dydaktyki zajmuje się zagadnieniami związanymi z interfejsami...
-
Impedance spectroscopy as a diagnostic tool of degradation of Solid Oxide Fuel Cells = Spektroskopia impedancyjna jako narzędzie diagnostyczne degradacji tlenkowych ogniw paliwowych
PublikacjaTlenkowe ogniwa paliwowe SOFC sa obecnie bliskie komercjalizacji. Wiedza na temat mechanizmów degradacji ogniw paliwowych jest niezbędna do dalszej poprawy ich działania. Spektroskopia impedancyjna jest skutecznym narzędziem diagnostycznym. Pozwala ona na wskazanie który element ogniwa SOFC ulega pogorszeniu oraz pozwala poznać dokładniej naturę procesu degradacji. W tej pracy degradacja ogniwa SOFC została zbadana przy użyciu...
-
Jacek Namieśnik prof. dr hab. inż.
OsobyUrodził się 10 grudnia 1949 r. w Mogilnie, zmarł 14 kwietnia 2019 r. w Gdańsku – polski chemik, profesor nauk chemicznych, specjalizujący się w chemii analitycznej i środowiskowej. Rektor Politechniki Gdańskiej w latach 2016–2019. Studia wyższe ukończył w 1972 r. na Wydziale Chemicznym Politechniki Gdańskiej, uzyskując tytuł magistra inżyniera chemika. W 1972 r. rozpoczął pracę na Politechnice Gdańskiej, gdzie w 1978 r. obronił...
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577642991]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577644281]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [802072957764671]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577644751]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [33007300694221]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Inseparability criteria based on matrices of moments
PublikacjaInseparability criteria for continuous and discrete bipartite quantum states based on moments of annihilationand creation operators are studied by developing the idea of Shchukin-Vogel criterion Phys. Rev. Lett. 95,230502 2005. If a state is separable, then the corresponding matrix of moments is separable too. Thus, wederive generalized criteria based on the separability properties of the matrix of moments. In particular, acriterion...
-
Effect of processing parameters on the cyclic behaviour of aluminium friction stir welded to spark plasma sintered aluminium matrix composites with bimodal micro-and nano-sized reinforcing alumina particles
PublikacjaUnderstanding the cyclic behaviour of Alumina reinforced Aluminium composites (Al-A2O3) was of critical importance, for their further application in the different industrial sectors. The present study is focussing on the cyclic behaviour of the Al-Alumina nanocomposite produced through the combination of spark plasma sintering (SPS) method and friction stir welding (FSW). The added Alumina with total content of 10% is the combination...
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577647341]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577645191]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 800 °C and 15% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 600 °C and 15% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 600 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included. Results converted...
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 15% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 100% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 100% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 20% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 20% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 5% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 5% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included. Results...
-
Jacek Ryl dr hab. inż.
OsobyStopień doktora nauk technicznych uzyskał w roku 2010. W tym samym roku podjął pracę w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej na Wydziale Chemicznym. W 2018 roku uzyskał stopień doktora habilitowanego nauk technicznych w dyscyplinie technologia chemiczna. Od 2021 roku zatrudniony w Instytucie Nanotechnologii i Inżynierii Materiałowej Wydziału Fizyki Technicznej i Matematyki Stosowanej PG. W pracy naukowej skupia...
-
Metaplastic carcinoma, NOS - Female, 61 - Cell image [8020729577646191]
Dane BadawczeThis is the histopathological image of BREAST cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577644951]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Jerzy Wtorek prof. dr hab. inż.
OsobyJerzy Wtorek uzyskał tytuł magistra inżyniera w 1976 roku na Wydziale Elektroniki Politechniki Gdańskiej, a stopień doktora nauk technicznych i doktora habilitowanego na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej, odpowiednio w 1986 i 2004 roku. Tytuł profesora uzyskał w 2016 r. Jego zainteresowania dotyczą nieinwazyjnych metod oceny układu krążenia, elektrycznych (aktywnych i pasywnych) właściwości...
-
Can matrix solid phase dispersion (MSPD) be more simplified? Application of solventless MSPD sample preparation method for GC–MS and GC–FID analysis of plant essential oil components
Publikacja -
Tool wear, surface roughness, cutting temperature and chips morphology evaluation of Al/TiN coated carbide cutting tools in milling of Cu–B–CrC based ceramic matrix composites
Publikacja -
Impedance Evaluation of the Effect of Ru[sub 0.3]Ti[sub 0.7]O[sub 2] on Electrochemical Properties of Polymeric Conducting Electrodes Used in Cathodic Protection
Publikacja -
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577648621]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577648371]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577645521]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577649101]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Corrosion behaviour of low carbon steel in artificial seawater using TP, LP, EIS, Harmonic Analysis (HA) and new method Dynamic Electrochemical Impedance Spectroscopy (DEIS)
PublikacjaZe względu na istotną rolę technik elektrochemicznych w badaniach procesów korozyjnych są one szeroko stosowane w monitorowaniu korozji. Celem niniejszej pracy jest zgromadzenie rezultatów wyników doświadczalnych uzyskanych różnymi technikami i znalezienie korelacji między nimi. Własności korozyjne stali stopowej (AISI 1026) w sztucznej wodzie morskiej zostały zbadane z wykorzystaniem ekstrapolacji tafelowskiej (TP), polaryzacji...
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017393821]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017392821]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017391621]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017393901]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017395081]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017391181]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577642751]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [130063001739121]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017397361]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [3300730069421971]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [130063001739361]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017397841]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.