Filtry
wszystkich: 15410
-
Katalog
- Publikacje 10484 wyników po odfiltrowaniu
- Czasopisma 437 wyników po odfiltrowaniu
- Konferencje 41 wyników po odfiltrowaniu
- Osoby 190 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 140 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 4113 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DISEASES , WAVELET TRANSFORMS , WAVELET ANALYSIS , GASTROINTESTINAL TRACT , ESOPHAGUS , SENSITIVITY , IMPEDANCE MEASUREMENT
-
Business Analysis Winter 2022/23
Kursy Online -
Business Analysis Winter 2023/24
Kursy Online -
Dynamic unattended measurement based routing algorithm for diffServ architecture
PublikacjaDynamic routing is very important in terms of assuring QoS in today's packet networks especially for streaming and elastic services. Existing solutions dedicated to dynamic routing are often too complicated and seem to be not usable in real time traffic scenarios where transferred traffic may vary significantly. This was the main reason for research and new routing mechanism proposal which should apply to today's packet networks....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Measurement Science Review
Czasopisma -
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublikacjaThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Virtual instrument using bilinear transformation for parameter identification of high impedance objects.
PublikacjaArtykuł przedstawia przyrząd wirtualny do pomiaru parametrów obiektów wysokoimpedancyjnych (/Zx/<10GOhm). Opracowano metodę identyfikacji elementów składowych dwójników wieloelementowych opartą na przekształceniu biliniowym.Metoda jest predestynowana do identyfikacji parametrów różnych powłok antykorozyjnych. Dla identyfikacji konieczne są wektorowe pomiary impedancji obiektu na kilku wybranych częstotliwościach, których liczba...
-
Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing
PublikacjaWe discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
High-quality Experiment Dedicated to microGravity Exploration, Heat Flow and Oscillation Measurement from Gdańsk
PublikacjaIn this paper we propose HEDGEHOG (High-quality Experiment Dedicated to microGravity Exploration, Heat flow and Oscillation measurement from Gdańsk) REXUS experiment to investigate vibrational and heat flow phenomena during the whole (ascent, microgravity phase, descent and recovery) flight of a sounding rocket. First, a proposed system of cantilever beams is discussed to study dynamic behaviour of dummy payload. Dimensioning has...
-
Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry
PublikacjaOne of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this...
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublikacjaThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters With Reduced Switch Count
Publikacjahis paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along with simulation and experimental verification are also provided. Possible application fields are discussed, as well as advantages and disadvantages....
-
Determining optimal gel sensitivity in optical CT scanning of gel dosimeters
Publikacja -
Sensitivity performance of all pole canonical low pass GmC filters.
PublikacjaW pracy badano własności częstotliwościowe kanonicznych filtrów dolnoprzepustowych GmC bez zer transmisyjnych. Przedstawiono ogólną strukturę kanonicznego filtru dolnoprzepustowego i jej opis macierzowy. Wyprowadzono ogólne wzory określające funkcje wrażliwościowe filtru. Dokonano porównania struktur do 10-go rzędu włącznie dla aproksymacji Butterwortha, Czebyshewa i Bessela.
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Dynamic Signal Strength Mapping and Analysis by Means of Mobile Geographic Information System
PublikacjaBluetooth beacons are becoming increasingly popular for various applications such as marketing or indoor navigation. However, designing a proper beacon installation requires knowledge of the possible sources of interference in the target environment. While theoretically beacon signal strength should decay linearly with log distance, on-site measurements usually reveal that noise from objects such as Wi-Fi networks operating in...
-
Electrochemical cell impedance spectra at Eoc+100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Gastrointestinal Endoscopy Clinics of North America
Czasopisma -
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublikacjaW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Designing a magnetoacoustic emission measurement configuration for measurement of creep damage in power plant boiler tubes
PublikacjaOpisywane są własności skonstruowanego detektora emisji magneto-akustycznej (EMA) służącego dla pomiaru stopnia degradacji rurociągów w przemyśle energetycznym. Specjalna budowa biegunów magnesu umożliwia ich dopasowanie do zakrzywionych powierzchni. Układ pomiarowy pozwala na badanie natężenia EMA dla pola wzdłuż osi rury, a także w kierunku obwodowym. Wykazano, iż możliwa jest detekcja zmiany stopnia degradacji materiału na obwodzie...
-
Educational Measurement-Issues and Practice
Czasopisma -
Journal of Food Measurement and Characterization
Czasopisma -
Mediterranean Journal of Measurement and Control
Czasopisma -
IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE
Czasopisma -
Modelling, Measurement and Control C
Czasopisma -
IET Science Measurement & Technology
Czasopisma -
Measurement-Interdisciplinary Research and Perspectives
Czasopisma -
Journal of Economic and Social Measurement
Czasopisma -
Modelling, Measurement and Control B
Czasopisma -
Measurement and Evaluation in Counseling and Development
Czasopisma -
Analysis of aircraft magnetic interference
PublikacjaThe magnetometric method is used among other things on mobile platforms (planes, helicopters) in military systems and in geological research. Optically-pumped and SQUID magnetometers are used in magnetic systems on airplanes. To be able to attain the sensitivity of modern magnetometers in flight, it is important that maneuver-related magnetic interference effects be minimized. The mathematical model of an aircraft as a source of...
-
Analysis of aircraft magnetic interference
PublikacjaThe magnetometric method is used among other things on mobile platforms (planes, helicopters) in military systems and in geological research. Optically-pumped and SQUID magnetometers are used in magnetic systems on airplanes. To be able to attain the sensitivity of modern magnetometers in flight, it is important that maneuver-related magnetic interference effects be minimized. The mathematical model of an aircraft as a source of...
-
On deterministic procedures for low-cost multi-objective design optimization of miniaturized impedance matching transformers
PublikacjaPurpose This paper aims to investigate deterministic strategies for low-cost multi-objective design optimization of compact microwave structures, specifically, impedance matching transformers. The considered methods involve surrogate modeling techniques and variable-fidelity electromagnetic (EM) simulations. In contrary to majority of conventional approaches, they do not rely on population-based metaheuristics, which permit lowering...
-
Improved Procedures for Feature-Based Suppression of Surface Texture High-Frequency Measurement Errors in the Wear Analysis of Cylinder Liner Topographies
Publikacja -
Application of Navigated Ultrasound for Assessment of the Anterior Pelvic Plane in Patients With Degenerative Hip Diseases
Publikacja -
Myeloperoxidase Modulates Inflammation in Generalized Pustular Psoriasis and Additional Rare Pustular Skin Diseases
Publikacja -
Ultra-rare ultra-care: Assessing the impact of caring for children with ultra rare diseases
Publikacja -
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublikacjaA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Modelling of Diffusing Capacity Measurement Results in Lung Microangiopathy Patients. A novel Diagnostic Suppport
PublikacjaLung microangiopathy is a little known negative influence of diabetes mellitus on the functioning of the lungs. The aim of this study is to design a supportive method for diagnosing lung microangiopathy. This will be based on routinely performed pulmonary measurements as well as on investigation process modelling and data processing. A model of the diffusion of oxygen from the alveoli to the blood has been described with a set...
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublikacjaA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublikacjaThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Coincidental Detection of Gastrointestinal Stromal Tumors During Laparoscopic Bariatric Procedures—Data and Treatment Strategy of a German Reference Center
Publikacja -
PHYSIOLOGICAL MEASUREMENT
Czasopisma -
Foundations of Capital Markets Analysis 2022
Kursy Online -
E-marketing and trend analysis - 2023
Kursy Online