Wyniki wyszukiwania dla: PROCESS MONITORING
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
The surface of a fragment of the structure of an integrated circuit in the semi-contact mode.
Dane BadawczeThe surface of a fragment of the structure of an integrated circuit. Topographic measurements in the semi-contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Biometryczna kontrola dostępu
PublikacjaOpisano szczegółowo algorytm detekcji oraz identyfikacji człowieka na podstawie punktów nodalnych twarzy. Zdefiniowano pojęcia: biometria, proces pomiaru biometrycznego, metody biometrycznej identyfikacji oraz kontrola dostępu. Przedstawiono opis opracowanego systemu biometrycznej identyfikacji wykorzystującego sztuczne sieci neuronowe. Podano wyniki badań oraz przeprowadzono ich wnikliwą dyskusję.Biometrics is the study of automated...
-
LIDAR data from a cliff measurement conducted in the vicinity of the town of Jastrzębia Góra on the Baltic Sea coast
Dane BadawczeMeasurement data were obtained during research related to the use of LiDAR observations to assess the stability of a coastal cliff. The collected information comes from measurements conducted in the vicinity of the town of Jastrzębia Góra on the Baltic Sea coast. The acquired point cloud constitutes a comprehensive set of data regarding the geometry...
-
Silicon microcantilever with impedance sensor
Dane BadawczeThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Demonstrator testera wbudowanego BIST dla układów w pełni różnicowych
PublikacjaPrzedstawiono demonstrator testera wbudowanego, przeznaczony do pracy na stanowisku dydaktycznym w laboratorium z przedmiotu Zaawansowane Metody Pomiarowe i Diagnostyczne. Na stanowisku studenci zapoznają się z technologią BIST (ang. Built-In Self-Test), która jest przykładem wdrożenia strategii projektowania dla testowania.
-
Occurrence and seasonal variations of 25 pharmaceutical residues in wastewater and drinking water treatment plants
PublikacjaThousands of tons of pharmaceuticals are introduced into the aqueous environment due to their incomplete elimination during treatment process in wastewater treatment plants (WWTPs) and water treat- ment plants (WTPs). The presence of pharmacologically active compounds in the environment is of a great interest because of their potential to cause negative effects. Furthermore, drugs can undergo different pro- cesses leading to the...
-
Variability in the distribution of phytoplankton as affected by changes to the main physical parameters in the Baltic Sea**The study was financially supported by the Polish State Committee of Scientific Research (grants: No. N N305 111636, N N306 353239) and ECOOP IP WP 10.1.3 Project. Partial support for this study was also provided by the Satellite Monitoring of the Baltic Sea Environment – SatBatłyk project founded by the European Union through European Regional Development Fund contract No. POIG 01.01.02-22-011/09.
Publikacja -
LIDAR data from a survey conducted in the vicinity of the town of Lake Lednica
Dane BadawczeThe measurement data was obtained during research aimed at utilizing LiDAR observations to assess changes occurring in the shoreline of Lake Lednica. The collected information comes from a spatial survey conducted using a scanner mounted on an unmanned aerial vehicle (ALS, in the IR channel). This advanced measurement system allows for precise registration...
-
Anthropogenic trace metals in Setiu Wetland: Spatial and seasonal distribution and implications for environmental health
PublikacjaThe growing urban wastewater volume poses a major global environmental challenge, especially in developing nations where inadequate treatment and discharge impact clean water availability. This study focused on Setiu Wetland, aiming to analyze seasonal and spatial variations of trace metals in particulate form from anthropogenic and pathogenic sources. Surface water samples were collected from multiple stations, measuring physical...
-
Results of modeling of pharmaceuticals mixtures toxicity with deviation ratio and best-fit functions models using Aliivibrio fischeri bacterium as model organism
Dane BadawczeThe research was concerned with verifying the impact of mixtures of nine pharmaceuticals against a selected organism, i.e., the bacterium Aliivibrio fischeri. A. fisheri is used as a model organism in the monitoring of acute toxicity in environmental and reference samples in Microtox® systems. Tested pharmaceuticals, namely: diclofenac (sodium salt),...
-
LIDAR data from a topographic survey conducted in the area where the Gdańsk Głowa Fortress was located
Dane BadawczeThe measurement data was obtained during research aimed at utilizing LiDAR observations to detect remnants of the historical complex of the Gdańsk Głowa Fortress. The collected information comes from a spatial survey conducted using a scanner mounted on an unmanned aerial vehicle. This advanced measurement system allows for precise registration of the...
-
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
SatBałtyk – A Baltic environmental satellite remote sensing system – an ongoing project in Poland. Part 2: Practical applicability and preliminary results**This work was carried out within the framework of the SatBałtyk project funded by the European Union through European Regional Development Fund, (contract No. POIG.01.01.02-22-011/09 entitled ‘The Satellite Monitoring of the Baltic Sea Environment’) and also as a part of IO PAS’s statutory research.The paper was presented in part at the 6th International Conference ‘Current Problems in the Optics of Natural Waters’, St. Petersburg, Russia, 6–10 September 2011.
Publikacja -
SatBałtyk – A Baltic environmental satellite remote sensing system – an ongoing project in Poland. Part 1: Assumptions, scope and operating range**This work was carried out within the framework of the SatBałtyk project funded by the European Union through European Regional Development Fund, (contract No. POIG.01.01.02-22-011/09 entitled ‘The Satellite Monitoring of the Baltic Sea Environment’) and also as a part of IO PAS’s statutory research.The paper was presented in part at the 6th International Conference ‘Current Problems in the Optics of Natural Waters’ St. Petersburg, Russia, 6–10 September 2011.
Publikacja -
Activation of the operational ecohydrodynamic model (3D CEMBS) – the hydrodynamic part **The original version of this paper appeared in the Geoscientific Model Development Discussion; here, we present the revised version, which takes all the reviewers’ comments into account.The study was supported by the Polish State Committee of Scientific Research (grants: N N305 111636, N N306 353239). Partial support was also provided by the Satellite Monitoring of the Baltic Sea Environment – SatBałtyk project funded by the European Union through the European Regional Development Fund contract No. POIG 01.01.02-22-011/09.
Publikacja -
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Katarzyna Januszewicz dr inż.
OsobyAbsolwentka Politechniki Gdańskiej, Wydziału Chemicznego kierunku Technologie Ochrony Środowiska, specjalność Monitoring i Analityka Zanieczyszczeń. Posiada stopień naukowy doktora w zakresie nauk technicznych. Zajmuje się w swoich badaniach od czasów studium doktoranckiego tematyką pirolizy tj. beztlenowej termicznej degradacji odpadów, w szczególności biomasą oraz zużytymi oponami. Badania dotyczą: procesu pirolizy różnego typu...
-
Hydrodynamic reanalysis of currents in the Baltic Sea using the PM3D model
Dane BadawczeThe dataset contains the results of numerical modeling of currents in the Baltic Sea since 1998. A long-term reanalysis was performed using a three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997).
-
Hydrodynamic reanalysis of ice conditions in the Baltic Sea using the PM3D model
Dane BadawczeThe dataset contains the results of numerical modeling of sea ice in the Baltic Sea since 1998. A long-term reanalysis was performed using the three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997). A numerical dynamic-thermodynamic model of sea ice (Herman et al. 2011)...
-
Hydrodynamic reanalysis of sea level in the Baltic Sea using the PM3D model
Dane BadawczeThe data set contains the results of numerical modelling of sea level fluctuations in the Baltic Sea in the Baltic Sea since 1998. A long-term reanalysis was performed using a three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997).
-
Hydrodynamic reanalysis of water temperature and salinity in the Baltic Sea using the PM3D model
Dane BadawczeThe dataset contains the results of numerical modeling of water temperature and salinity in the Baltic Sea since 1998. A long-term reanalysis was performed using the three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997). A numerical dynamic-thermodynamic model of sea...
-
Tomasz Edward Berezowski dr inż.
OsobyUrodził się w 1986 r. w Warszawie. Ukończył w 2009r. z wyróżnieniem Międzywydziałowe Studium Ochrony Środowiska SGGW w Warszawie, specjalność Restoration and Management of Environment. Doktorat obronił z wyróżnieniem na Vrije UIniversiteit Brussels w 2015 roku. W latach 2015-2017 pracował jako asystent, a następnie adiunkt na Wydziale Budownictwa i Inżynierii Środowiska SGGW. W roku 2017 został zatrudniony jako adiunkt na Wydziale...