Filtry
wszystkich: 3451
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: connected dominating set
-
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
CO-CURRICULAR ACTIVITIES IN TEACHING GEODESY
PublikacjaApart from education process based on the curricular activities, the whole set of co-curricular activities (CCAs) can help students to develope both expert knowledge and social skills. These activities are separated from academic course, sometimes placed outside of school or after regular school hours. Co-curricular activities such as students' scientific circles, workshops, conferences or festivals of science, publication, honor...
-
Simulation of the IT Service and Project Management Environment
PublikacjaThe authors of this paper present a simulation of the socio-technical system in which teams of students – regarded as low-maturity organizations – were given a task to utilize the (relatively) mature technologies that support IT project and service management. The experiment consisted of the following phases: teams formation, introduction to technologies used during the simulation, performing a set of reactive and proactive service...
-
Hydraulic equations for vortex separators dimensioning
PublikacjaThe paper presents a set of hydraulic expressions developed to design vortex separators. These devices are used for gravitational removal of suspensions from wastewater. Measurements and theoretical considerations allowed the authors to formulate a mathematically simple velocity field model. Than, equations describing particle motion in the separator were derived. Finally, a technical procedure for hydraulic design of vortex separators...
-
Robust Monitoring of Water Quality in Drinking Water Distribution System
PublikacjaThe paper develops a novel open loop set bounded observer for robust estimation of water quality in DWDS based on the advanced nonlinear quality dynamics model including disinfections by-products (DBPs). The observer utilises a cooperativeness of the quality dynamics model and is computationally efficient, hence applicable to on-line quality monitoring. The simulation results illustrate its good and sustainable performance.
-
Fourier transforms on Cantor sets: A study in non-Diophantine arithmetic and calculus
PublikacjaFractals equipped with intrinsic arithmetic lead to a natural definition of differentiation, integration, and complex structure. Applying the formalism to the problem of a Fourier transform on fractals we show that the resulting transform has all the required basic properties. As an example we discuss a sawtooth signal on the ternary middle-third Cantor set. The formalism works also for fractals that are not self-similar.
-
Design and investigations of the ethanol microturbine
PublikacjaThe paper presents the results of the design analysis and experimental investigations of the microturbine set consisting of the microturbine with partial admission and permanent magnet generator. The microturbine was designed for operation with the vapour of ethanol as a working fluid. Microturbine unit was tested for different parameters of the working fluid and varying the electrical load. The examples and the comparison between...
-
Rhetoric at school - a selection of the syllabi from the Academic Gymnasium in Gdańsk - transcription and photographs
Dane BadawczeThe following data set comprises a transcription (in txt and docx formats) and photographs (in jpg format) of the selected records from the Latin-language teaching syllabi termed 'Typus' or 'Catalogus lectionum' (an abbreviated title). Rhetoric is the main thematic criterion behind this choice. Various topics related to rhetoric have been taught not...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Tagged images with bees 2
Dane BadawczeImages taken from bee hive with tagged bees.
-
Parameter values for topological chaos in the reduced Chialvo model
Dane BadawczeThe following dataset is connected with a map-based neuron model introduced by D. Chialvo (Chaos, Solitons & Fractals, 5 (3-4) 1995). The reduced version of this model is a one dimensional discrete system which describes the evolution of the membrane voltage when the value of the second variable, the recovery variable, is fixed. We have recently...
-
Ambiphilic phosphorous compounds
Dane BadawczeResults of theoretical and experimental studies on ambiphilic phosphorous compounds:
-
Spectroscopic wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
Robust estimation of variables and parameters in dynamic water distribution systems
PublikacjaPrzedstawiono estymację metodą ''set membership'' zmiennych i parametrów systemu dystrybucji wody pitnej. Zmienne odnoszą się do ilości i jakości wody, natomiast parametry odnoszą się do modelu matematycznego hydrauliki. Problemten jest wysoce nieliniowy. Algorytm estymacji jest oparty na wcześniejszychpracach i wykorzystuje również algorytm dynamicznej linearyzacji odcinkami.
-
Design of precise control systems of industrial plants
PublikacjaA method for developing precision control systems in industry has been created based on a set of models that take into account the nonlinearity of the reactor model, the nonlinearities of the hydrodynamic regime and the accuracy of the control elements, the nonlinear characteristics and accuracy of the actuators, and the precision of the sensors used. A multidimensional precision control system has been developed for a continuous...
-
Experience Visualizaton
PublikacjaSet of Experience Knowledge Structure (SOEKS) has proved its capability of storing substantial part of experience at a particular decision point. The management of SOEKS record is also proposed in many papers for example referring to concepts of Decisional DNA knowledge representation, that is a collection of a number of SOEKS. The aim of this paper is to focus on visualization and practical aspects of presenting gathered knowledge...
-
Ontologically Aided Rule Model for the Implementation of ITIL Processes
PublikacjaThe implementation of ITIL processes in IT organizations can be seen as a set of interdependent projects. The sequence of the ITIL implementation relies on such parameters as scope, depth, the capability of processes and the maturity of the organization. These factors can form common patterns of ITIL implementation that might be expressed as rules. Also-to semantically reinforce such a model in its predictiveness and replicativeness-the...
-
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Current trends in the field of steganalysis and guidelines for constructions of new steganalysis schemes
PublikacjaThe paper concerns blind steganalysis techniques in the passive steganalysis scenario designed to detect the steganographic cover modification schemes. The goal is to investigate the state-of-art in the field of steganalysis, and, above all, to recognize current trends existing in this field and determine guidelines for constructions of new steganalysis schemes. The intended effects are to examine the possibilities for the development...
-
Mercury intrusion porosimetry (MIP) results of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
Dane BadawczeMercury intrusion porosimetry (MIP) data - curves of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
-
Analysis of spatial changes in the town of Puck with its surroundings in the years 1926, 1940, 1974, 1985, 2000, 2020 on the basis of topographic maps using the BDOT10K database
Dane BadawczeSpatial changes over time are extremely valuable due to the possibility of modeling forecasts. This dataset shows how Puck has evolved over a specific period of time. Thanks to this presentation of the data set, it is possible to easily recreate the appearance of the city in particular years.
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
PULSE and ECG measurement from the hand with elbows in the air - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...