1D portable optical coherence tomography system
Publikacja—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Detection system for optical coherence tomography: Czerny-Turner spectrometer
PublikacjaResearch methods based on spectral analysis have powerful impact on development in many field of science. Signal spectrum can be a source of useful and important data. It enables to obtain information about physical and chemical properties of tested materials. This paper has been devoted to describe optical design for high resolution spectrometer, which is significant element of optical coherence tomography (OCT) systems. Designed...
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublikacjaIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Crack monitoring in concrete beams under bending using ultrasonic waves and coda wave interferometry: the effect of excitation frequency on coda
PublikacjaConcrete is one of the most widely used construction materials in the world. In recent years, various non-destructive testing (NDT) and structural health monitoring (SHM) techniques have been investigated to improve the safety and control of the current condition of concrete structures. This study focuses on micro-crack monitoring in concrete beams. The experimental analysis was carried out on concrete elements subjected to three-point...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Marek Pszczoła dr hab. inż.
OsobyI am a Faculty member (Department of Highway and Transportation Engineering) at the Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Poland). My main research interests include: low-temperature properties of asphalt mixtures, low temperature cracking assessment of pavement structures, road materials properties, thermal stress analysis, design of pavement structures, airfield design and analysis....
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Nanoparticles displacement analysis using optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublikacjaSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Latent fingerprint imaging by spectroscopic optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a non-contact and non-invasive optical method for evaluating semitransparent and scattering objects. Its unique features, such as non-destructive 3D measurements of tested objects with a fast scanning rate, make this technique interesting for latent fingerprint reading, which is the subject of this paper. So far, OCT has not found widespread use for reading fingerprints directly from surfaces...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublikacjaSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Measuring the density of DNA films using ultraviolet-visible interferometry
PublikacjaIn order to determine a proper value for the density of dry DNA films we have used a method based upon the measurement of interference effects in transmission spectra of thin DNA layers. Our results show that the methodology is effective and the density of DNA in this state, 1.407 g/cm3, is much lower than the commonly used 1.7 g/cm3. Obtaining accurate values for the DNA film density will allow the optical constants for DNA to...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublikacjaThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Study of probe signal bandwidth influence on estimation of coherence bandwidth for underwater acoustic communication channel
PublikacjaA signal transmitted in a shallow Underwater Acoustic Communication (UAC) channel suffers from time dispersion due to the multipath propagation and the refraction phenomena. This causes intersymbol interference of the received signal and frequency-selective fading observed in its spectrum. Coherence bandwidth is one of the key transmission parameters used for designing the physical layer of a data transmission system to minimise...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublikacjaThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublikacjaIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublikacjaThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
The mediational role of future and past time perspectives in the relationship between negative affectivity and sense of coherence
PublikacjaSense of coherence (SoC) can promote positive coping, and one of its most prominent negative correlates is negative affectivity (NA). In the current study, we hypothesized that future and past time perspectives (TPs) will mediate the relationship between sense of coherence and negative affectivity, and the inverse relationship. The study was questionnaire-based, performed online. N = 719 participants aged 25-45 from...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublikacjaThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublikacjaOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Modeling of selected transducer designs for optical pressure sensors using polarization interferometry
PublikacjaW artykule przedstawiono wyniki modelowania metodą Elementów Skończonych wybranych konstrukcji membran do zastosowań w interferometrycznych czujnikach ciśnienia. Omówiono zależność prametrów membran od kształtu membrany, jej wymiarów i zastosowanego materiału. Zakres odkształcen badanych membran jest niezbyt duży, co może pogarszać dokładność pomiaru czujników ciśnienia, w których będą one stosowane Omówiono kierunki dalszych...
-
Dispersion compensation in optical coherence tomography
PublikacjaDyspersja wprowadzana przez system optycznej tomografii koherentnej (OCT) oraz badane obiekty powoduje zniekształcenia fazowe w zależności od długości fali widma promieniowania zastosowanego źródła optycznego. powoduje to rozmycie obrazów otrzymanych przekrojów badanych materiałów pogarszając właściwości metrologiczne systemu OCT. W artykule przedstawiono metody kompensacji dyspersji w systemie OCT oraz przedyskutowano ich właściwości.
-
The Medieval Low Countries
Czasopisma -
Polarization state analysis in optical coherence tomography
PublikacjaW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Polarization sensitive optical coherence tomography system
PublikacjaW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Synthesized light source for optical coherence tomography
PublikacjaW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Polarization sensitive optical coherence tomography with spectroscopic analysis
PublikacjaOptyczna tomografia koherentna (OCT) jest nieinwazyjną, nieniszczącą i bezkontaktową metodą obrazowania wewnętrznej struktury obiektów i materiałów rozpraszających. Dodatkowo w połączeniu z analizą stanu polaryzacji metoda ta umożliwia badanie lokalnych zmian optycznej anizotropii występującej w badanym obiekcie. W artykule przedstawiono zalety oraz ograniczenia metody oraz przedstawiono propozycję rozszerzenia analizy o badanie...
-
Landscape as the tool of coherence in the land management of rural communes
PublikacjaEconomic and social transformation of rural areas in Poland after 1990 reveals itself through disintegration of previous spatial order. Building a new pattern requires a vision, which would counteract complex causes of disintegration. The latter belong to institutional domain of planning strategies and the area of common practices. Therefore, agreement on aims and means between spatial policy strategies and tactics of space users...
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublikacjaBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Polarization sensitive optical coherence tomography for technical materials investigation
PublikacjaZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publikacja -
<title>Synthesized light source for optical coherence tomograph</title>
Publikacja -
Application of sol-gel-developed integrated optic devices to biochemical fiber optic sensors based on polarimetric interferometry.
PublikacjaW pracy omówiono zasady działania sensorów optycznych wykonanych w technologii optyki zintegrowanej i wykorzystujących interferometrię polaryzacyjną. Zaproponowano konstrukcję jednorazowego przetwornika pomiarowego, wykonanego w technologii sol-żel z materiałów hybrydowych, która umożliwia wykorzystanie nieodwracalnych reakcji chemicznych do pomiarów w medycynie, chemii i ochronie środowiska. Omówiono technologię syntezy materiałów...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublikacjaAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Journal of Low Power Electronics
Czasopisma -
Healthcare in Low-resource Settings
Czasopisma -
International Journal of Low Radiation
Czasopisma -
Early Modern Low Countries
Czasopisma -
JOURNAL OF LOW TEMPERATURE PHYSICS
Czasopisma -
LOW NOISE TIRES FOR HYBRID AND ELECTRIC VEHICLES
PublikacjaLow Emission Vehicles that are hybrid and electric cars may benefit from specially designed tires that are optimized for driving conditions typical for such vehicles. It is possible that in the future Low Emission Vehicles, especially passenger cars, will substitute conventional vehicles in all applications, however for the time being they are mostly used in urban and suburban areas. Urban traffic has a rather low demand for grip...
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublikacjaW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Emotional Costs, Social Influence, Sense of Coherence, and Coping in the Situation of Reemployment
Publikacja -
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013786841]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013782931]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013783131]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013783241]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.