Filtry
wszystkich: 1758
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DOUBLE-BAND ELECTRODE
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_006)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0011)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_009)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0017)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0021)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0020)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0019)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0024)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0023)
Dane BadawczeData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Bonding in Phosphanylphosphinidene Complexes of Transition Metals and their Correlation with Structures, 31 P NMR Spectra, and Reactivities
PublikacjaTheoretical studies of the bonding interactions and most important properties are carried out for isolable phosphanylphosphinidene complexes of transition metals. Three main types of phosphanylphosphinidene complexes are distinguished, based on the way in which the phosphanylphosphinidene ligand bonds to the metal center: (i) side-on complexes of platinum, where the R2Pβ–Pα ligand mimics structural features of free singlet phosphanylphosphinidenes...
-
XPS investigations of tge tin/tin oxides - CNT composites
Dane BadawczeThe composite of tin/tin oxide nanoparticles with graphene oxide and CMC based on laser ablation technique as an electrode material for energy storage devices were manufactured. The material exhibited a three-dimensional conducting graphene oxide network decorated with tin or tin oxide nanoparticles. The presence of tin/tin oxide in composites was...
-
A Wideband Rotary-Joint-Free H-Plane Horn Antenna With 360° Steerable Radiation Pattern Using Gap Waveguide Technology
PublikacjaConsidering the limitations of electronically steerable antennas such as limited steering span, gain degradation for large steering angles, complexity, and cost, this article is focused on the design of a simple mechanically steerable H-plane horn antenna. It is shown that since there is no need for an electrical connection between the top and bottom sections of a gap waveguide (GWG), if a sectoral horn is properly designed and realized...
-
RF Multi-Functional Input-Reflectionless Dispersive-Delay Structure With Sharp-Rejection Filtering Using Channelization Techniques
PublikacjaA class of RF multi-functional input-reflectionless dispersive-delay structure (DDS) with linear-type in-band groupdelay variation and sharp-rejection bandpass-filtering capability is reported. It exploits a two-branch-channelized/balanced-type circuit with similar low-order reflective DDS units inside its channels, which are connected through input/output 3-dB quadrature wideband couplers. The adopted DDS unit is based on a coupledresonator...
-
Highly Visible-Light-Photoactive Heterojunction Based on TiO2 Nanotubes Decorated by Pt Nanoparticles and Bi2S3 Quantum Dots
PublikacjaA heterojunction with excellent visible light response and stability based on titanium dioxide nanotubes (TiO2 NTs), bismuth sulfide quantum dots (Bi2S3 QDs), and platinum nanoparticles (Pt NPs) is proposed. Both Pt NPs (3.0 ± 0.2 nm) and Bi2S3 QDs (3.50 ± 0.20 nm) are well distributed on the (i) top parts, (ii) inner walls, and (iii) outer walls of the TiO2 NTs. Visible-light-induced photoreaction was initialized by excitation...
-
High frequency dynamics of an isotropic Timoshenko periodic beam by the use of the Time-domain Spectral Finite Element Method
PublikacjaIn this work results of numerical simulations and experimental measurements related to the high frequency dynamics of an aluminium Timoshenko periodic beam are presented. It was assumed by the authors that the source of beam structural periodicity comes from periodical alterations to its geometry due to the presence of appropriately arranged drill-holes. As a consequence of these alterations dynamic characteristics of the beam...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 75 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 65 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Analysis of the chemical composition of MnO-B2O3 glass
Dane BadawczeStructural and thermal properties of xMnO−(100−x)B2O3 (where x = 40, 50 and 60 mol%) glass samples have been investigated with the employment of various techniques. Fourier transform infrared spectroscopy results revealed the influence of MnO on glass matrix. Decrease of B–O bond-related band intensities has been observed. MnO addition was found to...
-
Low frequency nois of supecapacitor
Dane BadawczeDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Interference aware bluetooth scatternet (re)configuration algorithm IBLUERA
PublikacjaThis paper presents a new algorithm IBLUEREA, which enables reconfiguration of Bluetooth scatternet to reduce interference. IBLUEREA makes use of the complex model comparing ISM environment efficiency. The mechanism envisages the use of the assessment of the probability of successful (unsuccessful) frame transmission in order to take a decision concerning co-existence of technologies which make use of the same ISM band (here Bluetooth...
-
Compact antenna array comprising fractal-shaped microstripradiators
PublikacjaA design method of antenna array consisting of eight microstrip patches modified with Sierpinski fractal curves has been presented andexperimentally validated in this paper. Method proposed has enabled the achievement of considerable miniaturization of array length (26%),together with multi-band behavior of the antenna, which proves the attractiveness of presented design methodology and its ability to be implemented in more complex...
-
UAV Survey Images - DTM- Gdansk Church Pw. Św. Wojciecha - MP2
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Kościół Rzymskokatolicki Pw. Św. WojciechaLocation: Gdansk, Pomerania, PolandDrone type: DJI Mavic Pro 2Flight plan: Double GridTarget Product: Digital Terrain ModelDate: 02.04.2022Direct georeferencing: yesMetadata data: yes/GPSGCP: YESGCP Quality: RTKCamera Name: Hasselblad L1D-20cModel...
-
Determination of Chemical Diffusion Coefficient of Lithium Ions in Ceramics Derived from Pyrolysed Poly(1,2-dimethylsilazane) and Starch
PublikacjaThe apparent chemical diffusion coefficient Li+ (DappLI+) in pyrolysed poly(1,2-dimethylsilazane)/starch (PSN/S) (weight ratio: 30/70) ceramic anode composite is determined by galvanostatic intermittent titration technique (GITT). The electrode material composition is C6.00N0.14H0.47O0.12Si0.13. The calculated values of DappLI+, depend on the applied potential, vary from 10-14 to 10-9 [cm2/s]. The diffusion coefficient of lithium...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Multi-DBD actuator with floating interelectrode for aerodynamic control
PublikacjaIn this paper the use of a floating inter-electrode in a multi-DBD (dielectric barrier discharge) plasma actuator is described. The multi-DBD plasma actuators with floating inter-electrodes were investigated to get a longer DBD on a dielectric surface and to maximise generated net airflow. Our actuator was used to control the boundary layer flow separation around NACA0012 airfoil model. The results of our investigations suggests...
-
Beam Steerable MIMO Antenna Based on Conformal Passive Reflectarray Metasurface for 5G Millimeter-Wave Applications
PublikacjaA conformal reflectarray fed by a dual-band multiple-input multiple-output (MIMO) antenna is proposed for low-cost beam steering applications in 5G Millimeter-wave frequency bands. The beam steering is accomplished by selecting a specific port in the MIMO antenna. Each MIMO port is associated with a beam that points in a different direction due to a conformal reflectarray. This novel reflectarray antenna design has the advantages...
-
Electromagnetic Problems Requiring High-Precision Computations
PublikacjaAn overview of the applications of multiple-precision arithmetic in CEM was presented in this paper for the first time. Although double-precision floating-point arithmetic is sufficient for most scientific computations, there is an expanding body of electromagnetic problems requiring multiple-precision arithmetic. Software libraries facilitating these computations were described, and investigations requiring multiple-precision...
-
Pikselowy cyfrowy układ CDS przeznaczony do przetwornika obrazu CMOS
PublikacjaW artykule zaproponowano cyfrowy układ CDS (Correlated Double Sampling) przeznaczony do przetwornika obrazu CMOS. Układ różni się od klasycznych rozwiązań tym, że dwie pamięci przechowujące próbki sygnału wizyjnego zastąpiono jednym licznikiem rewersyjnym. Dzięki tej modyfikacji możliwa jest znaczna redukcja powierzchni układu CDS i umieszczenie go w każdym pikselu przetwornika obrazu CMOS. System został zaprojektowany i przesymulowany...
-
Photoelectron spectroscopy of brominated derivative of pyrimidine: 2-bromopyrimidine
PublikacjaIn this study the brominated derivative of pyrimidine, 2-bromopyrimidine, was investigated by photoelectron spectroscopy. Outer valence photoelectron spectra recorded at 21.22, 45 and 100 eV photon energy for this compound are presented. The recorded spectra have a higher resolution than that previously reported in the literature. The bromine 3d and 3p edge photoelectron spectra have also been recorded in a photon impact experiment...
-
Pikselowy cyfrowy układ CDS przeznaczony do przetwornika obrazu CMOS
PublikacjaW artykule zaproponowano cyfrowy układ CDS (Correlated Double Sampling) przeznaczony do przetwornika obrazu CMOS. Układ różni się od klasycznych rozwiązań tym, że dwie pamięci przechowujące próbki sygnału wizyjnego zastąpiono jednym licznikiem rewersyjnym. Dzięki tej modyfikacji możliwa jest znaczna redukcja powierzchni układu CDS i umieszczenie go w każdym pikselu przetwornika obrazu CMOS. System został zaprojektowany i przesymulowany...
-
VUV irradiation studies of plasmid DNA in aqueous solution
PublikacjaInteractions of VUV light and DNA samples in aqueous solutions are reported. The damage induced by such radiation is quantified by monitoring both loss of supercoiled DNA and formation of single and double strand breaks using agarose gel electrophoresis. Irradiations were performed using synchrotron VUV photons of 130, 150, 170 and 190 nm. VUV irradiation experiments revealed enhanced damage upon irradiation with 170 nm photons...
-
Low-Coherence Interferometer with Nanocrystalline Diamond Films with Potential Application to Measure Small Biological Samples
PublikacjaThe study investigates a case of a low-coherence fiber-optic Fabry–Prerot interferometer with a nanocrystalline diamond (NCD) mirror. The method of achieving double density of interference fringes is proposed by the application of birefringent material in the cavity of the interferometer. It can be used to reduce sample volume in comparison to conventional interferometers. The use of a biocompatible diamond mirror makes it specifically...
-
Helium-assisted, solvent-free electro-activation of 3D printed conductive carbon-polylactide electrodes
PublikacjaFused filament fabrication is one of the most rapidly developing 3D printing techniques, with numerous applications, including in the field of applied electrochemistry. Here, the utilisation of conductive carbon black polylactic acid (CB-PLA) for 3D printouts is the most promising. To use CB-PLA as an electrode material, an activation process must be performed, removing the polymer matrix and uncovering the electrically conductive...
-
Light-improved glucose sensing on ordered Au-Ti heterostructure
PublikacjaNon-enzymatic electrochemical platforms sensitive towards glucose presence have attracted a worldwide attention during last decades. We report on influence of solar light onto response of gold-titanium heterostructures prepared via controllable approach. The material based on Au nanoparticles orderly distributed over the structured titanium foil was obtained by electrochemical anodization followed by chemical etching, magnetron...
-
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublikacjaThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Structural, optical and electrochemical performance of black phosphorus and black arsenic-phosphorus nanostructures
PublikacjaBlack phosphorus (BP)-based nanostructures have drawn a lot of attention due to their tunable bandgap and extraordinary properties such as: high surface-to-volume ratio, large number of active sites, and prominent edges. However, low dimensional structures of black phosphorus oxidize easily, which hamper their application on a broader scale. One way to overcome these difficulties is to modify the black phosphorus structure by substituting...
-
Hydrogenation process ofTiO2/BiVO4/PEDOT:PSS observed by XPS method
Dane BadawczeTitania nanotubes synthesis was based on a two-stage anodization process at water/ethylene glycol (5%/95%) electrolyte containing 0.27 M NH4F and 1 M H3PO4 described previously. Anodization process was performed in two-electrode cell compartment using platinum mesh as a cathode. The distance between electrodes was about 2 cm. The anodization voltage...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Dane BadawczeThis dataset contains Dynamic EIS results obtained for the gold electrodes with non-functionalized gold nanocubes (AuNC) deposited at its surface. The deposition was the following: 2 uL of the solvent containing CTAB as the surfactant was put on the electrode and dried, the same procedure was applied 5 times. Afterward, the electrode was immersed in...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Dane BadawczeThis dataset contains Dynamic EIS results obtained for the gold electrodes with non-functionalized gold nanocubes (AuNC) deposited at its surface. The deposition was the following: 2 uL of the solvent containing CTAB as the surfactant was put on the electrode and dried, the same procedure was applied 5 times. Afterward, the electrode was immersed in...