Filtry
wszystkich: 14
Wyniki wyszukiwania dla: ARTIFICIAL SALIVA
-
Environmental degradation of titanium alloy in artificial saliva
PublikacjaThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Environmental degradation of Ti alloys in artificial saliva and a role of fluorides
PublikacjaThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Corrosion resistance examinations of Ti6Al4V alloy with the use of potentiodynamic method in Ringer`s and artificial saliva solutions
PublikacjaThe research results of corrosion resistance of the Ti6Al4V alloy in the simulated body fluids (SBF) are presented. The polished specimens have shown better corrosion resistance than grinded surfaces in both liquids. The artificial saliva has revealed more aggressive test solution than Ringer`s solution. The pitting tendency has been observed in Ringer`s solution for grinded specimens.
-
Assessing Acute Toxicity and Endocrine Disruption Potential of Selected Packages Internal Layers Extracts
PublikacjaThe focus of the present study is migration of toxic substances from food contact materials and its actual influence on the health of the final consumer. Two food packagings (metal cans, TetraPack®) and five simulants medias (water, ethanol, acetic acid, DMSO, artificial saliva) were selected for simulation studies. For assessment of acute toxicity and endocrine disruption potential of extract samples, two biotests (Microtox® and...
-
The mechanisms of degradation of titanium dental implants
PublikacjaTitanium dental implants show very good properties, unfortunately there are still issues regarding material wear due to corrosion, implant loosening, as well as biological factors—allergic reactions and inflammation leading to rejection of the implanted material. In order to avoid performing reimplantation operations, changes in the chemical composition and/or modifications of the surface layer of the materials are used. This research...
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Nanotubular Oxide Layer Formed on Helix Surfaces of Dental Screw Implants
PublikacjaSurface modification is used to extend the life of implants. To increase the corrosion resistance and improve the biocompatibility of metal implant materials, oxidation of the Ti-13Nb- 13Zr titanium alloy was used. The samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of...
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublikacjaSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Influence of Storage Time and Temperature on the Toxicity, Endocrine Potential, and Migration of Epoxy Resin Precursors in Extracts of Food Packaging Materials
PublikacjaThe aim of the present study was to establish a standard methodology for the extraction of epoxy resin precursors from several types of food packages (cans, multi-layered composite material, and cups) with selected simulation media (distilled water, 5% ethanol, 3% dimethyl sulfoxide, 5% acetic acid, artificial saliva) at different extraction times and temperatures (factors). Biological analyses were conducted to determine the acute...
-
Electrophoretic deposition (EPD) of nanohydroxyapatite - nanosilver coatings on Ti13Zr13Nb alloy
PublikacjaTitanium and its alloys are the biomaterials most frequently used in medical engineering, especially as parts of orthopedic and dental implants. The surfaces of titanium and its alloys are usually modified to improve their biocompatibility and bioactivity, for example, in connection with the deposition of hydroxyapatite coatings. The objective of the present research was to elaborate the technology of electrophoretic deposition...
-
Electrophoretic Deposition and Characterization of Chitosan/Eudragit E 100 Coatings on Titanium Substrate
PublikacjaCurrently, a significant problem is the production of coatings for titanium implants, which will be characterized by mechanical properties comparable to those of a human bone, high corrosion resistance, and low degradation rate in the body fluids. This paper aims to describe the properties of novel chitosan/Eudragit E 100 (chit/EE100) coatings deposited on titanium grade 2 substrate by the electrophoretic technique (EPD). The deposition...
-
Assessment of toxic and endocrine potential of substances migrating from selected toys and baby products
PublikacjaAnalysis of literature data shows that there is limited information about the harmful biological effects of mixture of compounds from the EDC group that are released from the surface of toys and objects intended for children and infants. One of the tools that can be used to obtain such information is appropriate bioanalytical tests. The aim of this research involved determining whether tests that use living organisms as an active...
-
Assessment of ecotoxicity and total volatile organic compound (TVOC) emissions from food and children's toy products
PublikacjaThe development of new methods for identifying a broad spectrum of analytes, as well as highly selective tools to provide the most accurate information regarding the processes and relationships in the world, has been an area of interest for researchers for many years. The information obtained with these tools provides valuable data to complement existing knowledge but, above all, to identify and determine previously unknown hazards. Recently,...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublikacjaThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...