Filtry
wszystkich: 4179
-
Katalog
- Publikacje 2822 wyników po odfiltrowaniu
- Czasopisma 46 wyników po odfiltrowaniu
- Konferencje 5 wyników po odfiltrowaniu
- Osoby 69 wyników po odfiltrowaniu
- Projekty 6 wyników po odfiltrowaniu
- Kursy Online 63 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 1167 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: CHARGE TRANSFER COMPLEX
-
Long-term measurement of physiological parameters - child (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 12. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (4h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 11. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 2 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 7th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 10th series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (13h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 9th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 4 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 8th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (10h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Inception and Propagation of Electrical Trees in the Presence of Space Charge in HVAC Extruded Cables
PublikacjaThis paper presents the space charge impact on the inception and propagation of electrical trees in cross-linked polyethylene (XLPE) insulation via simulations and experimentation. A 3D finite element analysis (FEA)-based modeling is proposed to simulate electrical trees via a needle embedded on the XLPE insulation. The proposed FEA model demonstrates the influence of the space charge magnitude and polarity on the initiation of...
-
Long-term measurement of physiological parameters - a teenager (9h and 20min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (9 hours and 20 minutes) measurement of physiological parameters was performed on...
-
In situ spectroelectrochemical and theoretical study on the oxidation of a 4H-imidazole-ruthenium dye adsorbed on nanocrystalline TiO2thin film electrodes
PublikacjaTerpyridine 4H-imidazole-ruthenium(ii) complexes are considered promising candidates for use as sensitizers in dye sensitized solar cells (DSSCs) by displaying broad absorption in the visible range, where the dominant absorption features are due to metal-to-ligand charge transfer (MLCT) transitions. The ruthenium(iii) intermediates resulting from photoinduced MLCT transitions are essential intermediates in the photoredox-cycle...
-
Resonance-Raman spectro-electrochemistry of intermediates in molecular artificial photosynthesis of bimetallic complexes
PublikacjaThe sequential order of photoinduced charge transfer processes and accompanying structure changes were analyzed by UV-vis and resonance-Raman spectroscopy of intermediates of a Ru(II) based photocatalytic hydrogen evolving system obtained by electrochemical reduction.
-
π-Stacking attraction vs. electrostatic repulsion: competing supramolecular interactions in a tpphz-bridged Ru(ii)/Au(iii) complex
PublikacjaThe synthesis and characterization of a mixed metal ruthenium(II)/gold(III) complex bridged by tetrapyridophenazine (tpphz) are described. It is isostructural and isoelectronic to the well-known photocatalysts with palladium(II) or platinum(II). Concentration dependent 1H-NMR spectroscopy and XRD studies show that the electrostatic repulsion between the gold(III) moieties exceeds the attractive π-stacking interaction. Theoretical...
-
Theoretical Investigation of the Electron-Transfer Dynamics and Photodegradation Pathways in a Hydrogen-Evolving Ruthenium-Palladium Photocatalyst
PublikacjaTime-dependent density functional theory calcula- tions combinedwith the Marcus theory of electron transfer (ET) were app lied on the molecular photocatalys t [(tbbpy) 2 Ru(tpph z)PdC l 2 ] 2 + in order to elucidate thelight-in- duced relaxation pathways populated upon excitation in the longer wavelength range of its absorption spectrum. The computational resultsshow that after the initial excitation, metal (Ru) to ligand (tpphz)chargetransfer...
-
Proton transfer and hydrogen bonds in supramolecular, self-assembled structures of imidazolium silanethiolates. X-ray, spectroscopic and theoretical studies
PublikacjaThe reaction of 1-methylimidazole, 2-ethyl-4-methylimidazole and 2-ethylimidazole with tris(2,6- diisopropylphenoxy)silanethiol (TDST) leads to the formation of three new salts, which have been characterized by elemental analyses, thermogravimetric analyses, FTIR spectroscopy, and their structures were determined by single-crystal X-ray diffraction. Structural analyses indicate that in all three compounds a proton transfer has...
-
Effect of shallow traps on admittance spectra of the system carrying SCLC and on values of charge carrier mobility extracted from susceptance
PublikacjaThe work concerns small-signal spectra of space-charge-limited current below threshold frequency (ft) of shallow traps. It is shown that below ft the small-signal concentration of trapped charge carriers is proportional to and in phase with small-signal concentration of free charge carriers, so there is no room for “slow shallow traps”. Conductance can be reduced by the traps, however no change in the range of real capacitance...
-
Optoelectronic properties of curved carbon systems
PublikacjaSystematic investigation of optoelectronic properties of curved carbon systems has been performed and the results have been compared with the representatives of flat carbon systems. Moreover, the application of third order dispersion corrected density functional tight binding method (with third order corrections of self-consistent charges) including Becke-Johnson dumping (DFTB3-D3(BJ)) has been validated in order to obtain reliable...
-
A non-adiabatic wavepacket dynamical study of the low energy chargetransfer process in the S3+ + H collision
PublikacjaThe collisional system S3+ + H?S2+ + H+ has been studied using a time-dependent wavepacket methodologyin two-dimensions. Using available potential energy surfaces and coupling matrix elementsobtained from multireference ab initio calculations, five non-adiabatically coupled electronic states of1P symmetry have been included in the dynamical simulations. The collision has been studied in thelow energy regime of 1-10 eV. The wavepacket...
-
Electrochemical and photoelectrochemical characterization of photoanodes based on titania nanotubes modified by a BiVO4 thin film and gold nanoparticles
PublikacjaTitania nanotubes (TNT) modified with thin films of bismuth vanadate (BiVO4) and gold nanoparticles (GNP) were photoelectrochemically characterized as photoanodes for water photooxidation. Presence of bismuth vanadate enhanced efficiency of photocurrent generation in comparison with pristine TNTs under visible light illumination. Besides an extended range of absorbed light, the presence of both BiVO4 and GNP reduced the charge...
-
Studies on the charge density distribution in p-substituted phenylnitrenium cation
PublikacjaAniline and its derivatives are known to be mutagenic. This activity is caused by the formation of phenylnitrenium cations during aniline oxidation. Reactivity of the positively charged chemical species can be measured by means of s+ substituent constant. In this paper charge density distribution in p-substituted nitrenium cations and reactivity indices such as, hardness η, electronegativity χ , and electrophilicily ω were analyzed....
-
Synthesis, structure, DNA binding and anticancer activity of mixed ligand ruthenium(II) complex
PublikacjaIn order to obtain a potential chemotherapeutic which is not affected on the normal BALB/3T3 cell line, a new arene ruthenium(II) complex {[RuCl(L1)(η6-p-cymene)]PF6}2 · H2O has been synthesized by a direct reaction of precursor, [{(η6-p-cymene)Ru(μ-Cl)}2Cl2], with N,N-chelating ligand (L1 - 2,2′-bis(4,5-dimethylimidazole). The compound has been fully characterized by elemental analysis, X-ray diffraction, IR, UV–Vis and 1H, 13C...
-
Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS2 devices
PublikacjaWe report on the depinning of nearly commensurate charge-density waves in 1T-TaS2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS2 is not accompanied by an observable abrupt increase in electric current—in striking contrast...
-
The influence of the thickness, recombination and space charge on the loss of photocurrent in organic semiconductors: an analytical model
PublikacjaWe propose an analytical model of the photocurrent efficiency dependence on the light intensity in organic semiconductors. The influence of the thickness of sample, space charge effects and recombination of charge on the loss of photocurrent has been considered. We demonstrate that the presented model is the enhancement of an analytical model reported recently by Rappaport et al (2005 J. Appl. Phys. 98 033714). The method to identify...
-
Oznaczanie tlenu – od metody Winklera do czujników enzymatycznych (Determination of oxygen – from Winkler Method to enzymatic sensor)
PublikacjaMonitoring of dioxygen levels is of utmost importance from the view-point of life processes, medical diagnostics, nutrition and chemical industries. In all these measurements both low and high levels of this element are important. The common methods for the determination of dioxygen are the Winkler method, Clark electrode and pulsoxymeters. A new, already strong field of research can be now recognized – the development of miniaturized...
-
Chemically Selective Alternatives to Photoferroelectrics for Polarization-Enhanced Photocatalysis: The Untapped Potential of Hybrid Inorganic Nanotubes
PublikacjaLinear-scaling density functional theory simulation of methylated imogolite nanotubes (NTs) elucidates the interplay between wall-polarization, bands separation, charge-transfer excitation, and tunable electrostatics inside and outside the NT-cavity. The results suggest that integration of polarization-enhanced selective photocatalysis and chemical separation into one overall dipole-free material should be possible.
-
Magnetism and charge density waves in RNiC2(R=Ce,Pr,Nd)
PublikacjaWe have compared the magnetic, transport, galvanomagnetic, and specific-heat properties of CeNiC2, PrNiC2, and NdNiC2 to study the interplay between charge density waves (CDW) and magnetism in these compounds. The negative magnetoresistance in NdNiC2 is discussed in terms of the partial destruction of charge density waves and an irreversible phase transition stabilized by the field-induced ferromagnetic transformation is reported....
-
Airstrip Ground Improvement Works by Blasting Charge Technique and Dredged-Ash Material Mixture
PublikacjaSoil improvement by blasting charge technique is known in geotechnics as one of the efficient and inexpensive method. It can be used in preparing of underground to found road construction and buildings as well. The technique proves usefulness especially when dynamic load is applied. It is because of non-stiff or rather resilient type soil after improvement. In noncohesive or organic soil, blasting charge...
-
Asynchronous Charge Carrier Injection in Perovskite Light-Emitting Transistors
PublikacjaUnbalanced mobility and injection of charge carriers in metal-halide perovskite light-emitting devices pose severe limitations to the efficiency and response time of the electroluminescence. Modulation of gate bias in methylammonium lead iodide light-emitting transistors has proven effective in increasing the brightness of light emission up to MHz frequencies. In this work, a new approach is developed to improve charge carrier...
-
Modelling of Graphene Field-Effect Transistor for lectronic sensing applications
PublikacjaA top-gated Graphene Field-Effect Transistor (GFET) suitable for electronic sensing applications was modelled. The applied simulation method reproduces correctly the output transfer GFET characteristics and allows to investigate doping effect caused by different physical, chemical or biological factors. The appearance of additional charge in the system results in the shift of the current-voltage characteristic. This feature could...
-
Triplet Formation and Triplet‐Triplet Annihilation Upconversion in Iodine Substituted Non‐Orthogonal BODIPY‐Perylene Dyads
PublikacjaBODIPY-perylene dyads have emerged as useful metal free sensitizers for triplet-triplet annihilation upconversion (TTAUC), these dyads are capable of efficient triplet generation via spinorbit charge transfer intersystem crossing (SOCT-ISC). This important route to triplet formation requires dyads in which two moieties are oriented perpendicular to each other. In this contribution, we give a deeper insight on the behavior of recently...
-
Aryl and N-arylamide carbon nanotubes for electrical coupling of laccase to electrodes in biofuel cells and biobatteries
PublikacjaSingle walled carbon nanotubes (SWCNTs) were equipped with aryl residues by chemical reactions. These insoluble materials were used to substitute classical soluble mediators, which help to transfer electrical charge between the conducting electrode and the redox active center of enzyme molecules. The effect of different aryl residues on the efficiency of the catalytic reduction of dioxygen in the presence of laccase was systematically...
-
Enhanced trap-assisted recombination in organic semiconductors
PublikacjaAn analytical model to describe the interaction of excitons and charge transfer states with deep traps is formulated for the case of molecular materials. Here, we have considered the influence of a trap-assisted recombination on this phenomenon. The final expression for the effective recombination rate has been derived from the Shockley–Read–Hall theory and kinetic equations which characterize different photophysical processes....