Filtry
wszystkich: 868
Wyniki wyszukiwania dla: EARTH FAULT CURRENTS
-
Behavior of residual current devices at earth fault currents with DC component
PublikacjaLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublikacjaIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Earth wires currents calculation by tableau analysis
PublikacjaThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Disturbances of Earth magnetic field caused by eddy currents of airplane
PublikacjaThe uniform magnetic field of the Earth in the surrounding of a mobile, metallic object undergoes deformation by eddy currents. The influence of the moving, conducting object on the Earth's total magnetic field depends on the object's shape, position and speed of the changes relative to the magnetic field vector of the Earth, as well as the electric conductivity and the relative magnetic permeability of the material. Disturbances...
-
Computer System for Evaluation of Shock Hazard in Circuits with Non-sinusoidal Earth Currents
PublikacjaEffects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents a computer system, based on LabVIEW environment,...
-
The effect of earth fault current harmonics on tripping of residual current devices
PublikacjaSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublikacjaW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublikacjaIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublikacjaIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublikacjaIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublikacjaCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Electric shock hazard in circuits with variable-speed drives
PublikacjaThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Tripping of F-type RCDs for high-frequency residual currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublikacjaThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Residual current devices in installations with PV energy sources
PublikacjaThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
Nowa metoda obliczania rozpływu prądów zwarciowych w przewodach odgromowych linii wysokiego napięcia
PublikacjaReferat przedstawia nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych w czasie zwarć, pozwalającą na dobór przewodów odgromowych pod względem wytrzymałości cieplnej. Proponowana metoda charakteryzuje się większą dokładnością i większą uniwersalnością niż powszechnie stosowane metody, pozwalając tym samym na dobór przewodów odgromowych z mniejszym ryzykiem niepewności. Prezentowana metoda obliczeniowa...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Uziemienia w zespołach elektrowni wiatrowych
PublikacjaW pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Trends in Locally Balanced Energy Systems without the Use of Fossil Fuels: A Review
PublikacjaIn recent years, the idea of the operation of energy systems (power systems, heating systems) has changed significantly. This paper is an overview of locally balanced energy systems without the use of fossil fuels. The paper justifies the concept of local energy balancing in a new energy system that does not use fossil fuels (coal, natural gas, and crude oil), based on European Union guidelines and formal documents as well as the...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublikacjaThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Tripping limitations of residual current devices in photovoltaic installations
PublikacjaIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublikacjaW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Residual current devices in electric vehicles charging installations
PublikacjaThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
System of protection against electric shock for circuits with power electronics converters
PublikacjaModern low voltage circuits are very often equipped with power electronics converters, therefore in these circuits non-sinusoidal earth currents (touch currents) may occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based...
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublikacjaEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublikacjaThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
Disturbances of magnetic field in surrounding of mobile, metalic plate
PublikacjaThe uniform magnetic field of the Earth in the surrounding of a mobile, metalic object undergoes deformation by eddy currents. The influence of the moving conducting object on total magnetic field of the Earth depends on the object's shape, position and speed of the changes relative to the magnetic field's vector of the Earth as well as the electric conductivity and the relative magnetic permeability of the material. The disturbances...
-
Decomposition of the induced magnetism degaussing problem for fast determination of currents in demagnetization coils wrapped outside an object under arbitrary external field conditions
PublikacjaSafe passage of ships in the presence of sea mines can be ensured by limiting or reducing the ship’s magnetic footprint. For vessels with plastic hulls, the main component that requires magnetic damping is the engine. Demagnetization of such an object can be achieved by wrapping it with coils and setting the direct current appropriately. For each specific geographic location, the currents in the coils can be determined iteratively...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Szybkie uziemniki do ograniczania skutków zwarć łukowych w okrętowych rozdzielnicach SN
PublikacjaW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu gazu ziemnego w stanie ciekłym. Na podstawie parametrów prądnic i silników odbiorników zasilanych z rozdzielnicy głównej obliczono prądy...
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublikacjaAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
The effect of current delay angle on tripping of residual current devices
PublikacjaPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublikacjaThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
Skutki zwarć łukowych w średnionapięciowych rozdzielnicach okrętowych z izolacją powietrzną
PublikacjaW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu kontenerów, w tym 600 kontenerów chłodzonych. Na podstawie parametrów prądnic i silników, odbiorników zasilanych z rozdzielnicy głównej...
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublikacjaRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
A Preliminary Study and Analysis of Tidal Stream Generators
PublikacjaFor a sustainable future, tidal energy can play a vital role. Tidal energy relies on the gravitational pull of the Moon and the Sun along with the centrifugal forces created by the Earth. Tidal barrage uses the potential energy from the tide and has been very successful in electricity production. With the help of a turbine, kinetic energy can also be harnessed from tidal currents to generate electricity. However, it is not economically...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublikacjaElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Broken rotor bar impact on sensorless control of induction machine
PublikacjaThe aim of the research is analysis of the sensorless control system of induction machine with broken rotor for diagnostic purposes. Increasing popularity of sensorless controlled variable speed drives requires research in area of reliability, range of stable operation, fault symptoms and application of diagnosis methods. T transformation (Cunha et al.,2003) used for conversion of instantaneous rotor currents electrical circuit...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublikacjaThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...