Wyniki wyszukiwania dla: FAULT DETECTION
-
IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes
Konferencje -
PCA based Fault Tolerant MPC
PublikacjaThis chapter presents a Fault Tolerant - Model Predictive Control (FT-MPC) schemes for sensor faults accommodation. A Fault Detection and Isolation (FDI) Unit, which is an integral part of FT-MPC system, is based on the Principal Component Analysis (PCA) method. Introduced approach enables efficient bias and drift faults accommodation in single, as well as simultaneous faults case. Simple simulation exercise is presented.Rozdział...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Michał Grochowski dr hab. inż.
OsobyProfessor and a Head of the Department of Intelligent Control and Decision Support Systems at Gdansk University of Technology (GUT). He is also a Member of the Board of the Digital Technologies Center of GUT. He received his M.Sc. degree in Control Engineering in 2000 from the Electrical and Control Engineering Faculty at the GUT. In 2004 he received a Ph.D. degree in Automatic Control and Robotics from this...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublikacjaStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublikacjaThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Fault diagnosis of marine 4-stroke diesel engines using a one-vs-one extreme learning ensemble
PublikacjaThis paper proposes a novel approach for intelligent fault diagnosis for stroke Diesel marine engines, which are commonly used in on-road and marine transportation. The safety and reliability of a ship's work rely strongly on the performance of such an engine; therefore, early detection of any type of failure that affects the engine is of crucial importance. Automatic diagnostic systems are of special importance because they can...
-
Zdzisław Kowalczuk prof. dr hab. inż.
OsobyW 1978 ukończył studia w zakresie automatyki i informatyki na Wydziale Elektroniki Politechniki Gdańskiej, następnie rozpoczął pracę na macierzystej uczelni. W 1986 obronił pracę doktorską, w 1993 habilitował się na Politechnice Śląskiej na podstawie pracy Dyskretne modele w projektowaniu układów sterowania. W 1996 mianowany profesorem nadzwyczajnym, w 2003 otrzymał tytuł profesora nauk technicznych. W 2006 założył i od tego czasu...
-
Fault diagnosing system of wheeled tractors
PublikacjaA defect of complex wheeled tractor assembles most frequently negative influence on exploitation efficiency, safety and exhaust gases emission. Structure complexity of wheeled tractors requires more and more advanced diagnostic methods for identification of their serviceable possibilities as well in manufacturing step as in exploitation. In classical diagnosing methods of wheeled tractor defects states mapping by measured diagnostic...
-
Application of data driven methods in diagnostic of selected process faults of nuclear power plant steam turbine
PublikacjaArticle presents a comparison of process anomaly detection in nuclear power plant steam turbine using combination of data driven methods. Three types of faults are considered: water hammering, fouling and thermocouple fault. As a virtual plant a nonlinear, dynamic, mathe- matical steam turbine model is used. Two approaches for fault detection using one class and two class classiers are tested and compared.
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Fault tolerant guarding of grids
PublikacjaW pracy rozważano problem strzeżenia krat dwuwymiarowych przez dwa niezależne zespoły straży. Wykazano, że zagadnienie minimalizacyjne jest NP-trudne i zaproponowano dla niego wielomianowy algorytm 6/5-przybliżony.
-
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublikacjaA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
Discrete measurement of fault-arc velocity
PublikacjaOpisano metodę dyskretnego pomiaru prędkości jednofazowego łuku awaryjnego poruszającego się w płaskim, poziomym układzie szyn. Badania przeprowadzono za pomocą punktowych czujników optycznych rozmieszczonych równomiernie wzdłuż szyn. Podano opis układu, jego charakterystykę, wpływ obszaru zjonizowanego na uzyskiwane wyniki i zależności między obserwowanymi wielkościami.
-
A Clustering-Based Methodology for Selection of Fault Tolerance Techniques
PublikacjaDevelopment of dependable applications requires selection of appropriate fault tolerance techniques that balance efficiency in fault handling and resulting consequences, such as increased development cost or performance degradation. This paper describes an advisory system that recommends fault tolerance techniques considering specified development and runtime application attributes. In the selection process, we use the K-means...
-
Optimising approach to designing kernel PCA model for diagnosis purposes with and without a priori known data reflecting faulty states
PublikacjaFault detection plays an important role in advanced control of complex dynamic systems since precise information about system condition enables efficient control. Data driven methods of fault detection give the chance to monitor the plant state purely based on gathered measurements. However, they especially nonlinear, still suffer from a lack of efficient and effective learning methods. In this paper we propose the two stages learning...
-
Kernel PCA in Application to Leakage Detection in Drinking Water Distribution System
PublikacjaMonitoring plays an important role in advanced control of complex dynamic systems. Precise information about system's behaviour, including faults detection, enables efficient control. Proposed method- Kernel Principal Component Analysis (KPCA), a representative of machine learning, skilfully takes full advantage of the well known PCA method and extends its application to nonlinear case. The paper explains the general idea of KPCA...
-
Tool support for ECSDM fault tree methodology
PublikacjaExtended Common Safety Description Model (ECSDM) jest językiem do formalnej specyfikacji systemów związanych z bezpieczeństwem oraz ich komponentów. Język ten zawiera konstrukcje umożliwiające specyfikację zależności czasowych. Może on zostać użyty w analizie drzew błędów, aby uzyskać jednoznaczną specyfikację hazardów w sytuacji, gdy są one uzależnione od związków czasowych pomiędzy przyczynami. Artykuł opisuje narzędzie wytworzone...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublikacjaA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
Mechanical Strength of MV Ship-switchgear During Fault Arc
PublikacjaIn the paper the analysis of pressure stressed in enclosure during fault arc inside switchgear is pre-sented as well. There is introduced the method based on determining stresses which are sum of tensile stresses (membrane) and deflection stresses. For tensile stresses nalysis the energy method, for unrestrainedly supported rectangular plate, was used. In the further part of the paper, the calculations and measurements results...