Filtry
wszystkich: 2865
-
Katalog
- Publikacje 2420 wyników po odfiltrowaniu
- Czasopisma 196 wyników po odfiltrowaniu
- Osoby 37 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 30 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Oferty 1 wyników po odfiltrowaniu
- Dane Badawcze 178 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: WASTEWATER TREATMENT PLANT
-
Anaerobic bacteria in wastewater treatment plant
Publikacja -
Mathematical Modelling in Diagnosis of Wastewater Treatment Plant
PublikacjaThe paper reports development of mathematical modeling in diagnosis of the WWTP. The algorithm is based on a comparition of data from the mathematical modeling and measurments of real datefrom WWTP, until it will detect any malfunction of the sensors in th case of study.
-
Microorganisms in the air over wastewater treatment plant.
PublikacjaCelem pracy było aktywności źródeł emisji mikroorganizmów do powietrza na terenie oczyszczalni ścieków. Stwierdzono iż najwyższe liczebności bakterii występowały w rejonie piaskowników i komór recyrkulacji osadu czynnego. Natomiast liczba bakterii w rejonie komór napowietrzania była zbliżona do tła.
-
Supervised model predictive control of wastewater treatment plant
PublikacjaAn optimizing control of a wastewater treatment plant (WWTP), allowing for cost savings over long time period and fulfilling effluent discharge limits at the same time, requires application of advanced control techniques. Model Predictive Control (MPC) is a very suitable control technology for a synthesis of such a truly multivariable controller that can handle constraints and accommodate model-based knowledge combined with hard...
-
Analysis of energy consumption at the Rzeszów Wastewater Treatment Plant
Publikacja -
Behavior of lipids in biological wastewater treatment plant processes
PublikacjaLipidy (oleje, smary, tłuszcze oraz długołańcuchowe kwasy tłuszczowe) są istotnym składnikiem ścieków. Ich ilość np. w ściekach komunalnych stanowi około 30-40% ogólnej wartości ChZT. Przemiany lipidów w procesach biologicznego oczyszczania są obiektem wielu badań, mimo to nie są do końca poznane i zrozumiane. W pracy przedstawiono przegląd literatury dotyczący przemian lipidów w trakcie tlenowego i beztlenowego oczyszczania ścieków...
-
Antimicrobial resistance of fecal indicators in muncipal wastewater treatment plant
PublikacjaAntimicrobial resistance of fecal coliforms (n = 153) and enterococci (n = 199) isolates was investigated in municipal wastewater treatment plant (WWTP) based on activated sludge system. The number of fecal indicators (in influent and effluent as well as in the aeration chamber and in return activated sludge mixture) was determined using selective media. Susceptibility of selected strains was tested against 19 (aminoglycosides,...
-
Environmental risk assessment of Polish wastewater treatment plant activity
PublikacjaWastewater treatment plants (WWTPs) play an extremely important role in shaping modern society's environmental wellbeing and awareness, however only well operated and supervised systems can be considered as environmentally sustainable. For this reason, an attempt was undertaken to assess the environmental burden posed by WWTPs in major Polish cities by collecting water samples prior to and just after wastewater release points....
-
Antimicrobial resistance of fecal indicators in municipal wastewater treatment plant
Publikacja -
Odour nuisance assessment of the food industry wastewater treatment plant
Publikacja -
Model based evaluation of plant improvement at a large wastewater treatment plant (WWTP)
PublikacjaIn this work, the effect of the improvement carried out at a large-scale wastewater treatment plant (WWTP) was evaluated, by means of modelling works, with the aim to determine the influence of the modernization over the process performance. After modernization, the energy consumption due to the aeration decreased about a 20% maintaining the effluent quality. In order to double-check the good effluent quality, modelling works were...
-
Model of aeration system at biological wastewater treatment plant for control design purposes
PublikacjaThe wastewater treatment plant (WWTP) is a dynamic, very complex system, in which the most important control parameter is the dissolved oxygen (DO) con-centration. The air is supplied to biological WWTP by the aeration system. Aera-tion is an important and expensive activity in WWTP. The aeration of sewage ful-fils a twofold role. Firstly, oxygen is provided as the main component for biolog-ical processes. Secondly, it supports...
-
BIOVAC® WASTEWATER TREATMENT PLANTS IN THE MOUNTAIN NATIONAL PARKS.
PublikacjaThis paper presents characteristics of the Biovac® wastewater treatment plants operating in the mountain areas of the Polish national parks (NP): Tatrzanski NP and Babiogórski NP as well as in the West Spitsbergen NP. On the basis of the laboratory tests performed on raw sewage and the final effluent the efficiency of the wastewater treatment plants was evaluated. It was found that high COD values and rather high COD / BOD5 ratios...
-
Assessment of the Effects of Wastewater Treatment Plant Modernization by Means of the Field Olfactometry Method
Publikacja -
The Effects of Wastewater Treatment Plant Failure on the Gulf of Gdansk (Southern Baltic Sea)
Publikacja -
Application of fuzzy neural network for supporting measurements and control in a wastewater treatment plant
PublikacjaOczyszczanie ścieków jest jednym z ważniejszych aspektów ochrony środowiska. Nowoczesne systemy kontroli w oczyszczalniach ścieków pozwalają na poprawę jakości procesu oczyszczania redukując jednocześnie koszty. Systemy kontroli i optymalizacji jakie odkilku lat opracowuje się dla oczyszczalni ścieków, bazują zazwyczaj na skomplikowanych modelach matematycznych. Kluczowym problemem w zastosowaniu tych systemów jest duża liczba...
-
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublikacjaA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
Task Scheduling – Review of Algorithms and Analysis of Potential Use in a Biological Wastewater Treatment Plant
PublikacjaThe idea of task scheduling is to increase the efficiency of a system by minimising wasted time, evenly loading machines, or maximising the throughput of machines. Moreover, the use of appropriate scheduling algorithms often leads to a reduction in the energy costs of the process. Task scheduling problems are found in a variety of industrial areas, and their scale changes significantly depending on the problem. This review shows...
-
Modelling of wastewater treatment plant for monitoring and control purposes by state - space wavelet networks
PublikacjaMost of industrial processes are nonlinear, not stationary, and dynamical with at least few different time scales in their internal dynamics and hardly measured states. A biological wastewater treatment plant falls into this category. The paper considers modelling such processes for monitorning and control purposes by using State - Space Wavelet Neural Networks (SSWN). The modelling method is illustrated based on bioreactors of...
-
Respiration rate estimation for model predictive control of dissolved oxygen in wastewater treatment plant
PublikacjaRespiration rate is very important parameter for biological processes in wastewater treatment plant (WWTP). The sequential algorithm for estimate the respiration rate is proposed and investigated. The Kalman filter (KF) is used. Simulation tests for the benchmark WWTP are presented.Respiracja jest bardzo ważnym parametrem dla prawidłowego przebiegu procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono i zbadano...