Wyniki wyszukiwania dla: biodegradable metallic implant
-
Conducting polymers for biodegradable metallic implants
PublikacjaNowadays permanent metallic cardiovascular stents are long-term implants. The long-time presence of such an implant in human body can cause overgrowth of tissue within the treated portion of the vessel, blockage of the circulatory system and many other clinical complications, such as thrombosis, prolonged physical irritations or chronic inflammation. Therefore, in recent years, there is an interest to create biodegradable metallic...
-
Conducting polymer films for biodegradable metallic cardiovascular stents
PublikacjaIn recent years, there is increasing interest to create biodegradable metallic cardiovascular stents instead of using their permanent form. The most interesting materials for this purpose are iron and its alloys. However, in order to use it in clinical application, their degradation rate and biological performance need to be optimized. One promising solution is coating the metal with conducting polymer films. In this work, short...
-
Electrophoretic deposition and characterization of composite chitosan/Eudragit E 100 or poly(4-vinylpyridine)/mesoporous bioactive glass nanoparticles coatings on pre-treated titanium for implant applications
PublikacjaTitanium implants are surface-modified to achieve bioactivity and often antibacterial properties. Such surface coatings may increase corrosion degradation and be weakly attached to the substrate. In the present research, biodegradable composite coatings, investigated so far as smart environment-sensitive, slowly releasing silver to the implant neighborhood, were produced as a combination of chitosan (CS) with Eudragit E 100 (EE100)...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublikacjaResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Structural changes of bacterial cellulose due to incubation in conditions simulating human plasma in the presence of selected pathogens
PublikacjaBacterial nanocellulose (BNC) is a natural biomaterial with a wide range of medical applications. However, it cannot be used as a biological implant of the circulatory system without checking whether it is biodegradable under human plasma conditions. This work aimed to investigate the BNC biodegradation by selected pathogens under conditions simulating human plasma. The BNC was incubated in simulated biological fluids with or...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublikacjaThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublikacjaTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublikacjaThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublikacjaTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
Bioactive core material for porous load-bearing implants
PublikacjaSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
The biological reactions on the implant-organism border
PublikacjaMateriał przeznaczony do implantacji w tkanki żywego organizmu powinien być biozgodny i biofunkcjonalny. Jeśli tak nie jest, ciało reaguje stanem zapalnym. Reakcje zapalne mogą się objawiać np. odrywaniem się cząstek materiału z powierzchni implantu na skutek tarcia lub nacisku, lub wytworzeniem biofilmu na jego powierzchni.
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Marcin Wekwejt dr inż.
OsobyMarcin Wekwejt, absolwent studiów inżynierskich w inż. biomedycznej (2016; Politechnika Bydgoska im. J. i J. Śniadeckich & Collegium Medicum im. L. Rydygiera), studiów magisterskich w inż. mechaniczno-medycznej (2018; Politechnika Gdańska & Gdański Uniwersytet Medyczny) oraz studiów doktoranckich w dyscyplinie inż. materiałowej (2021, Politechnika Gdańska). Uzyskał z wyróżnieniem stopień naukowy doktora nauk inżynieryjno-technicznych...
-
Surgical implant used in ventral hernia repair subjected to physiological pressure - computer simulation
PublikacjaW streszczeniu przedstawiono matemayczny model implantu wszczepionego pacjentowi podczas laparoskopowej naprawy przepukliny brzusznej. Wykonano go z użyciem metody elementów skończonych. Przyjęto ortotropowy model materiałowy implantu.
-
Robert Bogdanowicz dr hab. inż.
OsobyRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
Degradation of metallic implants
PublikacjaPresence of metallic implants made of stainless steels, Co and Ti alloys is sometimes followed by some undesired allergic reactions and inflammatory processes and consequently the necessity of reimplantation.
-
Developing Materials for Biodegradable Otolaryngological Stents
PublikacjaMaterials for otolaryngological stents have to be characterized by good tensile strength, wear resistance, biocompatibility, and specific degradation time. This work aimed to synthesize polyurethanes based on various biodegradable polyol blends. Their biodegradability and mechanical properties were tested and compared to commercial BIOFLEX material.
-
Biodegradable Polymer Packaging Materials in Seawater Environment
PublikacjaIn this chapter, our interest is directed into dea/ocean/lakes biodegradable environment for polymer packaging materials from two different points of view.