Filtry
wszystkich: 59
Wyniki wyszukiwania dla: doppler effect
-
Measurement of Impulse Response of Shallow Water Communication Channel by Correlation Method
PublikacjaPerformances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel; conditions that can additionally change in time due to the movement of the acoustic system transmitter and receiver or to reflection by underwater objects of the transmitted signal. The time-varying impulse response is a comprehensive description of dynamically changing transmission...
-
Counting and tracking vehicles using acoustic vector sensors
PublikacjaA method is presented for counting vehicles and for determining their movement direction by means of acoustic vector sensor application. The assumptions of the method employing spatial distribution of sound intensity determined with the help of an integrated 3D intensity probe are discussed. The intensity probe developed by the authors was used for the experiments. The mode of operation of the algorithm is presented in conjunction...
-
High frequency dynamics of an isotropic Timoshenko periodic beam by the use of the Time-domain Spectral Finite Element Method
PublikacjaIn this work results of numerical simulations and experimental measurements related to the high frequency dynamics of an aluminium Timoshenko periodic beam are presented. It was assumed by the authors that the source of beam structural periodicity comes from periodical alterations to its geometry due to the presence of appropriately arranged drill-holes. As a consequence of these alterations dynamic characteristics of the beam...
-
Detection and Imaging of Debonding in Adhesive Joints of Concrete Beams Strengthened with Steel Plates Using Guided Waves and Weighted Root Mean Square
PublikacjaStrengthening of engineering structures is an important issue, especially for elements subjected to variable loads. In the case of concrete beams or slabs, one of the most popular approaches assumes mounting an external reinforcement in the form of steel or composite elements by structural adhesives. A significant disadvantage of adhesive joints is the lack of access to the adhesive film for visual condition assessment, thus, there...
-
Analysis of Modal Parameters Using a Statistical Approach for Condition Monitoring of the Wind Turbine Blade
PublikacjaThe primary objective of the presented paper is the numerical and experimental investigation related to developing a useful diagnostic method, which can be used for determining the site and size of damage in laminated shells of wind turbine blades. The described detection technique is based on the analysis of low frequencies bending vibrations mode shapes of rotor blades. The authors used the commonly applied statistics methods...
-
A study on diagnosing both isotropic and orthotropic, intentionally damaged laminates
PublikacjaBeing the most detrimental mode in laminated structures, delamination initially degrades local structural strength, and lastly causes global structural failure, thus necessitating delamination identification at its incipient stages. For identification purposes, a comprehensive numerical and experimental study on delamination within both the laminated isotropic acrylic-glass and orthotropic epoxyglass plates is presented. As the...
-
Comparative study on the effectiveness of various types of road traffic intensity detectors
PublikacjaVehicle detection and speed measurements are crucial tasks in traffic monitoring systems. In this work, we focus on several types of electronic sensors, operating on different physical principles in order to compare their effectiveness in real traffic conditions. Commercial solutions are based on road tubes, microwave sensors, LiDARs, and video cameras. Distributed traffic monitoring systems require a high number of monitoring...
-
A three-dimensional periodic beam for vibroacoustic isolation purposes
PublikacjaThis paper presents results of investigations on a three-dimensional (3-D) isotropic periodic beam. The beam can represent a vibroacoustic isolator of optimised dynamic characteristics in the case of its longitudinal, flexural and torsional behaviour. The optimisation process concerned both the widths as well as the positions of particular frequency band gaps that are present in the frequency spectrum of the beam. Since the dynamic...
-
Damage Detection in the Wind Turbine Blade Using Root Mean Square and Experimental Modal Parameters
PublikacjaThe paper presents results of an experimental study related to a non-destructive diagnostic technique used for preliminary determination the location and size of delamination in composite coatings of wind turbine blades. The proposed method of damage detection is based on the analysis of the ten first mode shapes of bending vibrations, which correspond to displacements of rotor blades perpendicular to the rotor plane. Modal parameters...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublikacjaThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Invasive Assessment of the Myocardial Microcirculation during Beating Heart Coronary Artery Bypass Grafting
PublikacjaCoronary artery bypass grafting may be associated with several cardiac complications, including ischemia, acute myocardial infarction, arrhythmias, or hemodynamic instability. Accumulating evidence suggests that well-developed coronary collateral circulation may protect against adverse effects, including myocardial ischemia. Assessment of myocardial microvascular perfusion is, therefore, of great clinical interest in beating heart...
-
Pial artery and subarachnoid width response to apnoea in normal humans
PublikacjaBackground: Little is known about intracranial pressure (ICP)-cerebral haemodynamic interplay during repetitive apnoea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Method: We tested the complex response of the pial artery and subarachnoid width to apnoea...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublikacjaPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublikacjaBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
UUV and AUV Vehicles as the autonomous systems for naval applications
PublikacjaThere is a growing pressure to investigate how to design and build the unmanned underwater vehicles of different types which are devoted towards performing many tasks under the water surface according to the data missions. During the recent years the Department of Ship Design and Subsea Robotics, Faculty of Ocean Engineering and Ship Technology, Gdansk University of Technology designed and built a few types of unmanned underwater...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublikacjaUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Estimating Intercept Range of Silent Sonar
PublikacjaWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
Distance measurement errors in silent FM-CW sonar with matched filtering
PublikacjaThe secretiveness of sonar operation can be achieved by using continuous frequency-modulated sounding signalswith reduced power and significantly prolonged repeat time. The application of matched filtration in the sonarreceiver provides optimal conditions for detection against the background of white noise and reverberation, and avery good resolution of distance measurements of motionless targets. The article shows that target...
-
Analysis of distance measurement errors in CW FM sonar with MLS code modulation
PublikacjaAlthough used in the classic silent sonar, the CW FM sounding signal has a major flaw which is its inaccuracy in determining the distance to a target. The authors of the article have developed a concept of silent sonar using frequency modulation signals switched by pseudorandom codes, already discussed in their previous work. This article presents a detailed analysis of errors in CW FM sonar with pseudo-random sequence code modulation...