Wyniki wyszukiwania dla: equivalent sampling . validation . atmospheric aerosols . ion chromatography. uncertainty
-
Validation of atmospheric aerosols sampling in equivalent fractions
PublikacjaPhysical properties and chemical composition of atmospheric aerosols are of extreme importance, in many fields of interest, namely the Environment even with legal implications. Atmospheric sampling poses inherent problems with consequent demands on sampling optimisation, with sampling strategies requiring validation. In this work a study was conducted aiming at validating the collection of atmospheric aerosols in equivalent fractions....
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublikacjaIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Validation of a sampling procedure
PublikacjaEach step of the analytical procedure influences the final results in a significant way. In the majority of cases the analytical procedure encompasses sampling because the analysis of the entire object (material) is usually not possible. Thus it is necessary to include the uncertainty related to sampling procedure in the uncertainty budget calculations. This paper describes two basic ways of estimating the sampling uncertainty,...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Efficient uncertainty quantification using sequential sampling-based neural networks
PublikacjaUncertainty quantification (UQ) of an engineered system involves the identification of uncertainties, modeling of the uncertainties, and the forward propagation of the uncertainties through a system analysis model. In this work, a novel surrogate-based forward propagation algorithm for UQ is proposed. The proposed algorithm is a new and unique extension of the recent efficient global optimization using neural network (NN)-based...
-
Validation of a sampling procedure
Publikacja -
Ion Chromatography in Environmental Analysis of Selected Organic Acids
PublikacjaLow molecular mass carboxylic acids (LCAs) occur in many environmental compartments dueto natural processes and human activity. When volatile and nonvolatile acids are to be monitored then liquidchromatography, including ion chromatography seems a method of choice. At high pH the acids are inionized form and can be separated as carboxylats by means of anion exchange chromatography. LCAs canalso be separated at low pH by ion exclusion...
-
Atmospheric precipitation sampling for analysis
PublikacjaW pracy dokonano przeglądu różnych próbników stosowanych do pobierania próbek opadów atmosferycznych (wody deszczowe, mgła, wody spływne). Zaprezentowano urządzenia o różnym stopniu automatyzacji, od najprostszych konstrukcji do urządzeń kosztownych i wysoce zautomatyzowanych. W wielu publikacjach pomijane są informacje o stosowanej metodyce pobierania próbek oraz o położeniu stanowiska obserwacyjnego. Informacje te są jednak niezbędne,...
-
Sampling of atmospheric precipitation and deposits for analysis of atmospheric pollution
PublikacjaPrzedstawiono przegląd technik i przyrządów pomiarowych stosowanych w celu pobierania próbek mokrej i mgielnej depozycji (mgła, woda z chmur, szron, szadź, rosa). Przedstawiono również informacje literaturowe na temat oznaczania związków nieorganicznych i organicznych w próbkach opadów i osadów atmosferycznych z zastosowaniem odpowiednich technik pomiarowych.
-
Comparison of Ion Chromatography and Isotachophoresis for the Determination of selected Anions in Atmospheric Wet Deposition Samples
PublikacjaW pracy przedstawiono porównanie wyników oznaczenia zawartości wybranych anionów w próbkach opadów atmoferycznych z zastosowaniem technik izotachoforezy i chromatografii jonowej. Na podstawie otrzymanych wyników można stwierdzić, że technika chromatografii jonowej charakteryzuje się niższymi wartościami granic wykrywalności i oznaczalności, szerokim zakresem pomiarowym i możliwością oznaczania analitów w próbkach o róznym składzie...
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublikacjaThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Determination of Selected Organic Acids in Animal Farm Water Samples by Ion Chromatography
PublikacjaLow molecular mass carboxylic acids (LCAs) occur in many environmental compartments due to natural processes and human activity. They are an important group of organic pollutants of waste water that mainly includes, volatile fatty acids, and also dicarboxylic, aromatic, hydroxy- and ketoacids. LCAs are present in the environment at concentrations between 1 to 5000 ppm and different methods have been reported for their determination...
-
Journal of Verification, Validation and Uncertainty Quantification
Czasopisma -
Comprehensive two dimensional gas chromatography coupled with mass spectrometry as tool for characterization of the main pollutants present in atmospheric air in Gdansk
PublikacjaNowadays, the technique that is commonly used to identify and quantify the chemical compounds in gas sample is gas chromatography. The separation resolution in gas chromatography can be improved by applying the modulation technique. In this paper present is the most important information regarding the pollutants present in atmospheric air. The areas in which the tests were carried out are one of the largest industrial zones in...
-
Ion Chromatography with Pulsed Amperometric Detection for Determining Cyanide in Urine and Meconium Samples
PublikacjaThe parents’ addictions and eating habits have a significant influence on the child’s growth. The first stool of a newborn baby provides a large amount of information about xenobiotics transmitted by the mother’s body. The analytical technique used in the study is ion chromatography with pulsed amperometric detection (IC-PAD). The biological samples, which were obtained from women staying in a maternity ward and their partners,...
-
Zastosowanie chromatografii jonowej w analityce opadów i osadów atmosferycznych = Application of ion chromatography in atmospheric precipitation and deposit analysis
PublikacjaNajwiększy udział w dostawie zanieczyszczeń z atmosfery do powierzchni ziemi w regionach położonych w znacznych odległościach od źródeł emisji ma depozycja mokra (opady i osady atmosferyczne). Wody opadowe i wody spływne (również powstające z osadów atmosferycznych) dostają się wraz z zawartymi w nich związkami toksycznymi do wód powierzchniowych i gruntowych, które stanowią źródło wody pitnej. Pojawiła się więc konieczność stałego...
-
Validation and Regulatory Issues for Sample Preparation in: Comprehensive Sampling and Sample Preparation
PublikacjaW rozdziale opisano podstawowe terminy związane z walidacja procedury analitycznej. Szczególnie zwrócono uwagę na etapy pobierania i przygotowania próbek do analizy. Podano także rolę i znaczenie poszczególnych składowych procesu kontroli i zapewnienia jakości wyników pomiarów analitycznych.
-
Determination of thiocyanate (biomarkers of ETS) and other inorganic ions in human nasal discharge samples using ion chromatography
PublikacjaEnvironmental tobacco smoke (ETS) is a mixture of air and tobacco smoke containing more than 4000 chemical substances. In view of the health risks of many of these substances, studies are needed to determine biomarkers of exposure to ETS constituents in people who actively or passively are exposed to the toxic compounds. The methodologies for determining most biomarkers from saliva, urine and blood samples are known, but methods...
-
A solid phase extraction–ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples
PublikacjaA new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE – for sample preparation) coupled with ion chromatography–conductivity detection (IC-CD – for the final determination). Mean recoveries of...
-
Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
PublikacjaA simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat...