Filtry
wszystkich: 408
Wyniki wyszukiwania dla: impedance monitoring
-
Impedance monitoring of fuel cell stacks
PublikacjaThis paper presents an innovative, electrochemical impedance method for monitoring of electrochemical behaviour of a multi-cell, direct methanol fuel cell (DMFC) device. This method not only provides classical voltage changes at successive cells but also allows their detailed impedance behaviour to be presented. Impedance characteristics of individual cells within a fuel cell stack (depending on actual operating conditions) are...
-
Impedance monitoring of fuel cell stacks
Publikacja -
On-line Impedance Monitoring of Direct Methanol Fuel Cell
PublikacjaW niniejszej pracy została przedstawiona technika badawcza Dynamiczna Elektrochemiczna Spektroskopia Impedancyjna w obszarze badań ogniw paliwowych. Obiektem badań było ogniwo paliwowe zasilane bezpośrednio metanolem. Badano on-line wpływ zmian warunków pracy na globalną impedancję ogniwa. Podczas pomiarów zmianie ulegała temperatura, natężenia przepływu utleniacza oraz obciążenie.
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublikacjaThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublikacjaThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
Impedance monitoring of carbon steel cavitation erosion under the influence of corrosive factors
PublikacjaW pracy przedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej oraz funkcję ubytku masy powszechnie stosowaną do oceny odporności kawitacyjnej materiałów. Oszacowanie stopnia degradacji powierzchni, a także wpływu erozji na odporność korozyjną jest możliwe po zastosowaniu odpowiedniego elektrycznego...
-
Impedance monitoring of corrosion degradation of plasma electrolytic oxidation coatings (PEO) on magnesium alloy
PublikacjaImpedance technique based on continuous multisinusoidal current perturbation was used to explain degradation process of plasma electrolytic oxidation coatings (PEO) on magnesium alloy. An obtained impedance spectrum was fitted by electrical equivalent circuit to describe properties of conversion layer on magnesium alloy. Additionally, galvanostatic mode maintained during experiment, with DC current equal to zero, allowed to achieve...
-
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublikacjaThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublikacjaA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublikacjaW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublikacjaCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublikacjaThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublikacjaThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publikacja -
The impedance method of monitoring the degradation of rubber linings in applications where progressive deterioration is the predominant failure mechanism
Publikacja -
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublikacjaThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublikacjaDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
The influence of dynamic load changes on temporary impedance in hydrogen fuel cells, selection and validation of the electrical equivalent circuit
PublikacjaTo achieve optimal performance of a fuel cell, a reliable monitoring and diagnostic method is required. The currently utilized methods give limited information or they are impossible to use under dynamic working conditions. To obtain comprehensive information about the fuel cell operation we utilized novel dynamic electrochemical impedance spectroscopy. Impedance measurements in dynamic mode were performed on a hydrogen fuel cell,...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublikacjaWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
The impedance of hydrogen oxidation reaction in a proton exchange membrane fuel cell in the presence of carbon monoxide in hydrogen stream
PublikacjaEvaluation of performance of a proton exchange membrane fuel cell, which is affected by carbon monoxide that pollutes the hydrogen stream, was presented. This influence was studied for carbon monoxide concentration of 125–325 ppb, which are close to values specified in ISO 14687:2019 standard. Performed studies provided crucial information for further development of fuel cell as an energy source for automotive application. Impedance...