wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: optical fiber sensorlong-period fiber gratingsrefractive index sensingthin filmindium tin oxideelectrochemistry
-
ZnO ALD-Coated Microsphere-Based Sensors for Temperature Measurements
PublikacjaIn this paper, the application of a microsphere-based fiber-optic sensor with a 200 nm zinc oxide (ZnO) coating, deposited by the Atomic Layer Deposition (ALD) method, for temperature measurements between 100 and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor head in real-time, which allows for higher accuracy during...
-
The SARS‐CoV ‐2 specific IgG antibodies biophotonic sensor
PublikacjaIn this paper, we present the design and the principle of operation of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific immunoglobulin G (IgG) biophotonic sensor, which is based on the single-mode telecommunication fiber. We fabricated the sensor head at the face of the single mode fiber-28. Due to the process of bio-functionalization, our sensor has the ability to selectively detect the SARS-CoV-2 specific...
-
Bibliographic data on datasets affiliated to Most Wiedzy and indexed in Data Citation Index (retrieved by Web of Science service in December 2021)
Dane BadawczeThe file contains the number of datasetes published by the reserchers affiliated to Most Wiedzy and indexed in Data Citation Index provided by Web of Science. The Search was performed using the name of institution in the 'address' filed or 'group author' filed . Data retrieved and published during the '5th Open Science Conference (1-3.12.2021).
-
Elective surgery system strengthening: development, measurement, and validation of the surgical preparedness index across 1632 hospitals in 119 countries
Publikacja -
Janusz Datta prof. dr hab. inż.
OsobyJanusz Datta w roku 1988 ukończył studia na Wydziale Chemicznym Politechniki Gdańskiej. Po ich zakończeniu został zatrudniony na Wydziale Chemicznym w Zakładzie, a potem po reorganizacji, w Katedrze Technologii Polimerów, gdzie przez sześć lat pracował na stanowisku naukowo-technicznym. W tym okresie zdobywał doświadczenie uczestnicząc w licznych wyjazdach do Zakładów Chemicznych „Zachem” Bydgoszcz, gdzie brał udział w pracach...
-
Michał Mazur dr inż.
OsobyAktualne zainteresowania inżynieria mechaniczna, robotyka, drgania mechaniczne, analiza modalna, sterowanie, systemy czasu rzeczywistego Wybrane publikacje Kaliński K., Galewski M., Mazur M., Chodnicki M, 2017, Modelling and Simulation Of A New Variable Stiffness Holder for Milling Of Flexible Details, Polish Maritime Research, vol 24, ss. 115-124 Kaliński K. J., Mazur M.: Optimal control at energy performance index of the mobile...
-
Tool wear, surface roughness, cutting temperature and chips morphology evaluation of Al/TiN coated carbide cutting tools in milling of Cu–B–CrC based ceramic matrix composites
Publikacja -
Bibliographic data on datasets affiliated to Maria Curie-Skłodowska University and indexed in Data Citation Index (retrieved by Web of Science service in February2022)
Dane BadawczeThe file contains the number of datasets published by the researchers affiliated to Maria Curie-Skłodowska University and indexed in Data Citation Index provided by Web of Science. The Search was performer using the name of institution in the address field or group author field. Data retrieved and published during the 5th Open Science Conference (1-3.12.2021)
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 64 mA. Sample 91. Image period: 5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 64 mA. Sample 91. Pictures were taken relatively fast, with period of 5 sec in order to examine the fast fluctuations of sample temperature during...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 120 mA. Sample 103. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 120 mA. Sample 103. Thermographic pictures were taken relatively fast, with period of 0,5 sec in order to examine the fast fluctuations of sample...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,3 V at 420 mA. Sample 103. Image period: 2 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,3 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken relatively fast, with period of 2 sec in order to examine the fast fluctuations of sample temperature during...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,5 V at 420 mA. Sample 103. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,5 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 1 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103. Image period: 1 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec in order to examine the fast fluctuations of sample temperature during charging - discharging...
-
Bibliographic data on datasets affiliated to Gdansk University of Technology and indexed in Data Citation Index (retrieved by Web of Science service in December 21)
Dane BadawczeThe file contains the number of datasets published by the researchers affiliated to Gdansk University of Technology and indexed in Data Citation Index provided by Web of Science. The Search was performed on the 1st of December 2021 using the name of institution in the 'address' and 'group author' field. Data retrieved and published during the 5th Open...
-
Mariusz Kaczmarek dr hab. inż.
OsobyReceived M.Sc., Eng. in Electronics in 1995 from Gdansk University of Technology, Ph.D. in Medical Electronics in 2003 and habilitation in Biocybernetics and Biomedical Engineering in 2017. He was an investigator in about 13 projects receiving a number of awards, including four best papers, practical innovations (7 medals and awards) and also the Andronicos G. Kantsios Award and Siemens Award. Main research activities: the issues...
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublikacjaFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Assessment of heat stress in a hot environment using the WBGTeff index according to the standard PN-EN ISO 7243:2018-01
Publikacja -
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 1 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Gini index in selected European Union countries in 2017.
Dane BadawczeWhen assessing the level of poverty, one should use indicators presenting indicators of social inequality in terms of income, indicators of prosperity and poverty. In Poland, the situation in terms of inequality is improving, but as measured by the Gini coefficient.
-
Optical and photocatalytic properties of rare earth metal-modified ZnO quantum dots
Publikacja -
Simultaneous Optimization of Unicast and Anycast Flows and Replica Location in Survivable Optical Networks
PublikacjaDotychczasowe prace z zakresu ochrony sieci przed awariami dotyczyły przypadku transmisji unicast. W niniejszym artykule rozważamy problem ochrony transmisji anycast (jeden-do-jednego-z-wielu). Jako wariant ochrony stosujemy podejście pojedynczej ścieżki zabezpieczającej (ang. path protection), chroniącej przed awarią pojedynczego węzła.Wprowadzono nowe modele programowania całkowitoliczbowego optymalnego znajdowania tras oraz...
-
Optical properties of a dielectric slab front-loaded with a grating of plasmonic silver nanowires
Publikacja -
Thallium indium germanium sulphide (TlInGe2S6) as efficient material for nonlinear optical application
Publikacja -
Modeling of selected transducer designs for optical pressure sensors using polarization interferometry
PublikacjaW artykule przedstawiono wyniki modelowania metodą Elementów Skończonych wybranych konstrukcji membran do zastosowań w interferometrycznych czujnikach ciśnienia. Omówiono zależność prametrów membran od kształtu membrany, jej wymiarów i zastosowanego materiału. Zakres odkształcen badanych membran jest niezbyt duży, co może pogarszać dokładność pomiaru czujników ciśnienia, w których będą one stosowane Omówiono kierunki dalszych...
-
Priority-enabled optimization of resource utilization in fault-tolerant optical transport networks.
PublikacjaW artykule zaproponowano nowe podejście do optymalizacji rozdziału zasobów przeżywalnych sieci rozległych, które uzależnia szybkość przywracania ciągłości połączenia od klasy usługi. Wykazano, iż proponowana metoda nie powoduje wydłużania ścieżek zabezpieczających (w przypadku usług w wymaganej wysokiej jakości obsługi) lub czyni to w sposób minimalny (dla pozostały usług). Ze względu na fakt, że zadanie znalezienia ścieżek aktywnych...
-
Electro-optical system for the automated selection of dental implants according to their colour matching
Publikacja -
Optical Fibre Control-Measurement Systems Of Compound HV/HP Electrical Equipment
Publikacja -
High Quality Medical Image-Guides By Mosaic-Assembling Optical Fibre Technology
Publikacja -
Pi of the Sky – all-sky, real-time search for fast optical transients
Publikacja -
Potential Aluminium(III)- and Gallium(III)-selective Optical Sensors Based on Porphyrazines
Publikacja -
Fast dynamics in the optical storage with Langmuira-Blodgett films of a diazocrown ether molecule
PublikacjaMolekuły z resztą azobenzenu badano z punktu widzenia licznych aplikacji wykorzystujących cykle fotoizomeryzacji trans-cis-trans, wiodących do uporządkowania cząsteczek, a nawet do transportu masy w mikroskali. Ważnym ograniczeniem dla tych materiałów jest powolna dynamika procesu porządkowania, wymagającego molekularnych przekształceń. W tej pracy informujemy o filmach Langmuira-Blodgett (LB) pochodnej eteru azokoronowego (29-membered...
-
Reduction of spectral interferences in atmospheric pressure glow discharge optical emission spectrometry
Publikacja -
Optical, colloidal and biological properties of up-converting nanoparticles embedded in polyester nanocarriers
Publikacja -
Deposition of EDOT-Decorated Hollow Nanocapsules into PEDOT Films for Optical and Electrochemical Sensing
Publikacja -
Potential application of pure silica optical flat fibers for radiation therapy dosimetry
Publikacja -
In situ optical studies of thermal stability of iodine-doped polyazomethine thin films
Publikacja -
Electronic and optical properties of theMg2−xFexSiO4spinel: From band insulator to Mott insulator
Publikacja -
SU‐GG‐T‐290: A Fast Optical CT Scanner for Gel Dosimetry
Publikacja -
Electronic structure and optical properties of boron doped single-wall carbon nanotubes
Publikacja -
Iron(III)-selective materials based on a catechol-bearing amide for optical sensing
PublikacjaThe synthesis and ion-binding properties of a new amide L derived from 3,4-dihydroxybenzoic acid are described. Due to the presence of a catechol unit, the compound interacts selectively with iron(III) in organic solvent (dimethyl sulfoxide, DMSO) to produce a color change from pale yellow to green. The incorporation of the ligand L into polymeric matrices or its encapsulation into surfactant-based spheres enables analyte detection...
-
Tunable semiconductor laser application for interferometric optical fibersensors.Optical and Electronic Sensors V.
PublikacjaW pracy przedstawiono metody stabilizacji punktu pracy światłowodowych sensorów interferometrycznych. W metodach tych wykorzystuje się układy regulacji sterujące długością fali przestrajalnego lasera półprzewodnikowego. Przedstawiono tryby pracy układów regulacji oraz problemy związane z ich projektowaniem i realizacją. Przeanalizowano ograniczenia sensorów wykorzystujących powyższe układy. Dokonano weryfikacji eksperymentalnej...
-
Sythesis and Characterization of Optical Sol-Gel Adhesive for Military Protective Polycabonate Resin.Wytwarz
PublikacjaPrzedstawiono proces syntezy spoiw optycznych do laminatów poliwęglanowych. Scharakteryzowano właściwości optyczne i mechniczne. W procesie syntezy zastosowano monitoring ramanowski do diagnostyki przebiegu bazowych reakcji chemicznych.
-
Bibliographic data on datasets (from 2020) affiliated to Most Wiedzy and indexed in Data Citation Index (retrieved by Web of Science service in December 2021)
Dane BadawczeThe file contains the number of datasets published by the researchers affiliated to Most Wiedzy and indexed in Data Citation Index by Web of Science. The Search was perfprmed using the name of institution in the 'assress' filed or 'group author' field. Data retrieved and published during the 5th Open Science Conference (1-3.12.2021).
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K04
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K05
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K03
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...