Filtry
wszystkich: 5826
-
Katalog
- Publikacje 4558 wyników po odfiltrowaniu
- Czasopisma 39 wyników po odfiltrowaniu
- Osoby 55 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 39 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 1128 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: FLOW CYTOMETRY
-
Analysis of 5-Hydroxymethyluracil Levels Using Flow Cytometry
Publikacja -
Flow cytometry as an estimation tool for honey bee sperm viability
Publikacja -
Survey for neoplasia in Macoma balthica from the Gulf of Gdansk using flow cytometry.
Publikacja -
Flow cytometric assessment of homeostatic aging of reticulocytes in rats
Publikacja -
Method of determination of the reticulocyte age distribution from flow cytometry count by a structured-population model
Publikacja -
Flow cytometric analysis of reticulocyte maturation after erythropoietin administration in rats
Publikacja -
Flow cytometric sorting and analysis of human epidermal stem cell candidates
Publikacja -
Isolation of Human Progenitor Epidermal Cells on Collagen Type IV and Analysis of Their Markers with Flow Cytometry and PCR Methods
PublikacjaEpidermal stem cells, located in the skin, together with keratinocytes are transplanted in regenerative therapies, e.g., for the treatment of burns or other wounds. Here, we describe the protocol of their enzymatic isolation from human skin. It includes separation of the epidermis form the dermis by incubation with dispase followed by cell isolation for epidermis by digestion with trypsin. Cell isolated with this method can be...
-
Transactions of the Institute of Fluid-Flow Machinery
Czasopisma -
Flow Cytometric Assessment of Endothelial and Platelet Microparticles in Patients With Atrial Fibrillation Treated With Dabigatran
Publikacja -
Flow cytometric approach to evaluate the impact of hydro-technical concrete compounds’ release to the freshwater microbiome
PublikacjaThe aim of this research was to test the potential of applying a flow cytometric procedure to evaluate the impact of concrete compounds’ release to the freshwater microbiome. Cells from the collected samples were stained with a fluorogenic redox indicator dye that measures the redox potential of microbial cells. This novel approach was combined with the assessment of microorganisms’ penetration into the internal structures of concrete...
-
CYTOMETRY PART B-CLINICAL CYTOMETRY
Czasopisma -
Neoplasia detection in Macoma balthica (Bivalvia) from the Gulf of Gdansk (Baltic Sea, Poland) — comparison of flow cytometry, histology and chromosome analysis.
Publikacja -
Current Protocols in Cytometry
Czasopisma -
DISTRIBUTION OF FLOWS IN A CHANNEL NETWORK UNDER STEADY FLOW CONDITIONS
PublikacjaThe article presents an algorithm for calculating the distribution of flow in a junction of open channel network under steady flow conditions. The article presents a simplified calculation algorithm used to estimate the distribution of flow in a network of channels under steady flow conditions. The presented algorithm is based on the continuity equation and a simplified energy equation. To describe the relationship between the...
-
CYTOMETRY PART A
Czasopisma -
Clinical Optometry
Czasopisma -
Journal of Optometry
Czasopisma -
Simplified Numerical Model for Transient Flow of Slurries at Low Concentration
PublikacjaRapid transients are particularly dangerous in industrial hydro-transport systems, where solid-liquid mixtures are transported via long pressure pipelines. A mathematical description of such flow is difficult due to the complexity of phenomena and difficulties in determining parameters. The main aim of the study was to examine the influence of the simplified mixture density and wave celerity description on satisfactory reproduction...
-
FLOW TURBULENCE AND COMBUSTION
Czasopisma -
FLOW MEASUREMENT AND INSTRUMENTATION
Czasopisma -
Journal of Flow Chemistry
Czasopisma -
Flow Maps and Flow Patterns of R1233zd(E) in a Circular Minichannel at Low, Medium and High Values of Saturation Pressure
PublikacjaThere is a gap in knowledge regarding the flow pattern of low-boiling working fluids in the range of high saturation temperatures (above 120°C) and medium and high reduced pressures (0.5-0.9). Data are present in the literature for similar values of reduced pressures, but for lower values of saturation temperature. This is due to the existing refrigeration applications of these working fluids. At high values of reduced pressure,...
-
Study of proapoptotic activity of anthraquinone derivatives towards A549 cancer cells using flow cytometry
Dane BadawczeThis study presents the fluorescence intensity of Annexin V/7AAD and caspase 3/7 which correspond to the proapoptotic activity of anthraquinone derivatives towards A549 cancer cells.
-
Study of proapoptotic activity of anthraquinone derivatives towards H226 cancer cells using flow cytometry
Dane BadawczeThis study presents the fluorescence intensity of Annexin V/7AAD and caspase 3/7 which correspond to the proapoptotic activity of anthraquinone derivatives towards H226 cancer cells.
-
Polyacrylamide substrate viscosity impact on temozolomide activity in glioblastoma cells by flow cytometry and rheological measurements
Dane BadawczeDataset includes raw data on cell lines LN-229 and LN-18 treated with temozolomide measured by flow cytometry, rheometry and cell projections. It also includes calculations necessary for creation of figures and conclusions based on those figures in the publication titiled: "Substrate viscosity impairs temozolomide-mediated inhibition of glioblastoma...
-
Experimental and Computational Multiphase Flow
Czasopisma -
Clinical and Experimental Optometry
Czasopisma -
Clinical and Refractive Optometry
Czasopisma -
Advances in Ophthalmology and Optometry
Czasopisma -
OPTOMETRY AND VISION SCIENCE
Czasopisma -
<title>Modeling of noncontact temperature measurement system using multiwavelength pyrometry</title>
Publikacja -
Flow cytometry analysis of DNA DSBs in telomerase positive and negative cell lines after treatment with TXT2 and TXT4
Dane BadawczeFlow cytometry analysis of DNA DSBs in telomerase positive (A549, H460) and negative (NHBE2594, U2OS) cell lines after treatment with equitoxic concentrations of TXT2 and TXT4. MTX and DMSO were used as positive and negative controls, respectively.
-
Flow cytometry analysis of caspase 3/7 activation in A549, H460 and U2OS cells after exposure to TXT2 and TXT4
Dane BadawczeThe data contains flow cytometry analysis of caspase 3/7 activation in A549, H460 and U2OS cells after exposure to equitoxic concentrations of TXT2 and TXT4. DMSO and MTX were used as positive and negative controls, respectively. Caspase 3/7 activity was detected using CellEvent™ Caspase-3/7 Green Flow Cytometry Assay Kit (#C10427, Thermo Fisher Scientific)....
-
Decolorization of organic dyes solution by atmospheric pressure glow discharge system working in a liquid flow-through mode
Publikacja -
Experimental Study of Flow Rate in Hydraulic Satellite Motor with the Rotating Case at a Low Constant Rotational Speed
PublikacjaIn this article was described the methodology for the experimental study of flows in the prototype of a satellite hydraulic motor with a rotating body. The experimental tests of the motor were carried out at a low constant rotational speed in a wide range of pressure drop in this motor. The constant rotational speed of the motor was kept by a worm gear. Based on the test results, the leakage characteristics in the flat gaps of...
-
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW
Czasopisma -
Journal of Flow Visualization and Image Processing
Czasopisma -
Flow boiling intensification in minichannels by means of mechanical flow turbulising inserts
PublikacjaThe work presents the results of experimental investigation on heat transfer in minichannels. Refrigerant R123 was used as a test fluid. Single vertical silver tubes of 380 mm length and 2.3 mm diameter were examined with two variants of turbulising inserts. A wide range of parameters was considered, namely mass flux G=534-3011 kg/(m2s), heat flux qw=28.5-68.4 kW/m2, saturation temperature Tsat=23-86 stC and the full range of vapour...
-
About nutrient liquid flow between potential flow and cartilage surface in bioreactor
PublikacjaW niniejszej pracy wyznaczony został przepływ cieczy odżywczej o właściwościach nienewtonowskich w cienkiej warstwie granicznej w pobliżu powierzchni komórek chrząstki (chondrocytu) podczas hodowli w bioreaktorze. Ruch cieczy w warstwie granicznej jest wywołany wydatkiem przepływu dostarczanej cieczy do bioreaktora. Ponadto prędkość przepływu cieczy w warstwie granicznej wokół hodowanych komórek chrząstki stawowej jest uzależniona...
-
A Comparison of Simplified Two-dimensional Flow Models Exemplified by Water Flow in a Cavern
PublikacjaThe paper shows the results of a comparison of simplified models describing a two-dimensional water flow in the example of a water flow through a straight channel sector with a cavern. The following models were tested: the two-dimensional potential flow model, the Stokes model and the Navier-Stokes model. In order to solve the first two, the boundary element method was employed, whereas to solve the Navier-Stokes equations, the...
-
Non-adiabatic Effects in Pressure Drop Calculations in Flow Boiling and Flow Condensation in Minichannels
PublikacjaConsiderations presented in the paper relate both to the case of flow boiling and flow condensation in conventional channels as well as small diameter ones. Authors devoted all the possible attention that the modeling presented is applicable to the whole range of quality variation in both cases of condensation and boiling. The form of two-phase flow multiplier, which is a major factor in modeling presented here, should be capable...
-
Flow distribution and heat transfer in minigap and minichannel heat exchangers during flow boiling
PublikacjaThe topic of boiling heat transfer in miniscale geometries has focused the ever increasing interest of researchers in recent years. However, most of the works are related to mini- and microchannels and much less to minigaps. Meanwhile, minigaps allow for more comprehensive experimental studies, i.e. flow visualisations due to the flat, two-dimensional configuration of the flow. The results of the experimental investigations of...
-
Membrane distillation with laminar flow
Publikacja -
Management of complexity and information flow
PublikacjaProblemy złożoności i zarządzania przepływem informacji. W rozdziale omówio-no podejście do modelowania systemów złożonych oraz zarządzania przepływeminformacji w takich systemach. Rozwiązania odniesiono do płaszczyzny elasty-cznego wytwarzania. Poruszono aspekty miękkiego modelowania w takich środo-wiskach.
-
The lemniscate knowledge flow model
PublikacjaKnowledge is seen as one of the main resources for organizations providing knowledge-intensive services. Therefore, sharing and reusing are the main goals of modern knowledge management (KM) approach, driven by information and communication technologies (ICT). However, one can ask for the details in order to provide means and tools to design and deploy environment able to fulfil these two goals. We observed that occurred interactions...
-
Flow Analysis of a Kaplan Turbine
PublikacjaThis monograph is a guide to a method of experimental and numerical flow investigations for Kaplan - type turbines. The numerical calculations were compared with the test results of the model Kaplan turbine. The tests were carried out on the model test rig in the Gdańsk University of Technology. The turbine has been thoroughly experimentally investigated, resulting in the identification of optimum setting combination of the stator...
-
High-order compact difference algorithm on half-staggered meshes for low Mach number flows
Publikacja -
Comparitive study of heat transfer and pressure drop during flow boiling and flow condensation in minichannels
PublikacjaIn the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation...
-
Effect of asymmetric fluid flow distribution on flow boiling in a microchannel heat sink – An experimental investigation
PublikacjaFlow boiling in microchannels is emerging as an exclusive cooling solution for miniaturized high-power electronic devices alongside having other high heat flux applications. Size miniaturization at microscale strangely increases heat transfer performance as well as flow boiling instabilities. Many flow boiling instabilities are interrelated and result from imperfect hydrodynamic conditions. One of such problems is flow maldistribution among...