Filters
total: 4853
filtered: 3624
-
Catalog
- Publications 3624 available results
- Journals 95 available results
- Conferences 7 available results
- Publishing Houses 1 available results
- People 45 available results
- Projects 1 available results
- e-Learning Courses 21 available results
- Events 7 available results
- Open Research Data 1052 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: rate%20of%20speech%20estimation
-
Real-time speech-rate modification experiments
PublicationAn algorithm designed for real-time speech time scale modification (stretching) is proposed, providing a combination of typical synchronous overlap and add based time scale modification algorithm and signal redundancy detection algorithms that allow to remove parts of the speech signal and replace them with the stretched speech signal fragments. Effectiveness of signal processing algorithms are examined experimentally together...
-
Chirp-rate estimation of FM signals in the time-frequency domain
PublicationNovel dynamic representations of a complex signal in the time-frequency domain including: a channelized instantaneous complex frequency (CICF), a complex local group delay (CLGD) and a channelized instantaneous chirp-rate (CICR) are introduced. The proposed approach is based on the use of the gradient of the short-time Fourier transform complex phase. An interpretation of the newly-introduced distributions especially of the CICR...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Sonar Pulse Detection Using Chirp Rate Estimation and CFAR Algorithms
PublicationThis paper presents a new approach to sonar pulse detection. The method uses chirp rate estimators and algorithms for the adaptive threshold, commonly used in radiolocation. The proposed approach allows detection of pulses of unknown parameters, which may be used in passive hydrolocation or jamming detection in underwater communication. Such an analysis is possible thanks to a new kind of imaging, which presents signal energy in...
-
Chirp Rate and Instantaneous Frequency Estimation: Application to Recursive Vertical Synchrosqueezing
PublicationThis letter introduces new chirp rate and instantaneous frequency estimators designed for frequency-modulated signals. These estimators are first investigated from a deterministic point of view, then compared together in terms of statistical efficiency. They are also used to design new recursive versions of the vertically synchrosqueezed short-time Fourier transform, using a previously published method (D. Fourer, F. Auger, and...
-
Respiratory Rate Estimation Based on Detected Mask Area in Thermal Images
PublicationThe popularity of non-contact methods of measuring vital signs, particularly respiratory rate, has increased during the SARS-COV-2 pandemic. Breathing parameters can be estimated by analysis of temperature changes observed in thermal images of nostrils or mouth regions. However, wearing virus-protection face masks prevents direct detection of such face regions. In this work, we propose to use an automatic mask detection approach...
-
Evaluating Accuracy of Respiratory Rate Estimation from Super Resolved Thermal Imagery
PublicationNon-contact estimation of Respiratory Rate (RR) has revolutionized the process of establishing the measurement by surpassing some issues related to attaching sensors to a body, e.g. epidermal stripping, skin disruption and pain. In this study, we perform further experiments with image processing-based RR estimation by using various image enhancement algorithms. Specifically, we employ Super Resolution (SR) Deep Learning (DL) network...
-
Doubly miniaturized rat-race hybrid coupler
PublicationTwo complementary miniaturization techniques have beenapplied to reduce the size of a rat-race hybrid coupler: (i) conventional microstrip sections have been replaced with their diminished lowimpedance counterparts as the first step of size reduction and (ii) novel fractal-shaped compact microstrip resonant cells dedicated to efficiently shorten low-impedance transmission line segments have been implemented as the second step of...
-
Estimation of the excitation variances of speech and noise AR-models for enhanced speech coding
Publication -
Respiration rate estimation for model predictive control of dissolved oxygen in wastewater treatment plant
PublicationRespiration rate is very important parameter for biological processes in wastewater treatment plant (WWTP). The sequential algorithm for estimate the respiration rate is proposed and investigated. The Kalman filter (KF) is used. Simulation tests for the benchmark WWTP are presented.Respiracja jest bardzo ważnym parametrem dla prawidłowego przebiegu procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono i zbadano...
-
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublicationA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
On the EM algorithm for the estimation of speech AR parameters in noise
Publication -
Improving Accuracy of Contactless Respiratory Rate Estimation by Enhancing Thermal Sequences with Deep Neural Networks
PublicationEstimation of vital signs using image processing techniques have already been proved to have a potential for supporting remote medical diagnostics and replacing traditional measurements that usually require special hardware and electrodes placed on a body. In this paper, we further extend studies on contactless Respiratory Rate (RR) estimation from extremely low resolution thermal imagery by enhancing acquired sequences using Deep...
-
A novel method of local chirp-rate estimation of LFM chirp signals in the time-frequency domain
PublicationIn the paper, novel dynamic representations of a complex signal in the time-frequency domain are introduced. The proposed approach is based on using the gradient of the short-time Fourier transform complex phase. A channelized instantaneous complex frequency (CICF) and a complex local group delay (CLGD) are included in the presented signal representations. An application of the newly-introduced distributions is demonstrated by...
-
Doubly miniaturized rat-race coupler with periodic pbg structures
PublicationW referacie zaprezentowano projekt oraz wyniki eksperymentu podwójnie zminiaturyzowanego sprzęgacza pierścieniowego. Wstępny stopień miniaturyzacji uzyskano poprzez modyfikację impedancji charakterystycznych oraz długości elektrycznych odpowiednich sekcji linii mikropaskowych, natomiast dodatkową redukcję powierzchni osiągnięto poprzez implementację kaskad komórek PBG w odcinkach linii mikropaskowych. Wyniki eksperymentu potwierdzają...
-
A robust design of a numerically demanding compact rat-race coupler
PublicationA fast and accurate design procedure of a computationally expensive microwave circuit has been presented step-by-step and experimentally validated on the basis of a compact rat-race coupler (RRC) comprising slow-wave resonant structures (SWRSs). The final compact RRC solution has been obtained by means of a sequential optimization scheme exploiting the implicit space mapping (ISM) algorithm. A well-suited surrogate optimization...
-
A CMRC-based compact rat-race coupler with harmonic suppression
PublicationIn this paper, an eective miniaturization technique exploiting compact microstrip resonant cells has been discussed and experimentally validated on the basis of a 3-dB microstrip rat-race coupler. The application of the method proposed has resulted in 91 % circuit area reduction in comparison to a conventional rat-race coupler. Experimental results show good agreement with theoretical characteristics, as well as an additional eect,...
-
Cost-Efficient Design Methodology for Compact Rat-Race Couplers
PublicationIn this article, a reliable and low-cost design methodology for simulation-driven optimization of miniaturized rat-race couplers (RRCs) is presented. We exploit a two-stage design approach, where a composite structure (a basic building block of the RRC structure) is first optimized using a pattern search algorithm, and, subsequently, the entire coupler is tuned by means of surrogate-based optimization (SBO) procedure. SBO is executed...
-
Improving Accuracy of Respiratory Rate Estimation by Restoring High Resolution Features With Transformers and Recursive Convolutional Models
PublicationNon-contact evaluation of vital signs has been becoming increasingly important, especially in light of the COVID- 19 pandemic, which is causing the whole world to examine people’s interactions in public places at a scale never seen before. However, evaluating one’s vital signs can be a relatively complex procedure, which requires both time and physical contact between examiner and examinee. These re- quirements limit the number...
-
A compact microstrip rat-race coupler constituted by nonuniform transmission lines
PublicationIn this work, a step-by-step development of a compact microstrip rat-race coupler (RRC) has been presented and discussed. A high degree of miniaturization has been obtained by substituting six quarter-wavelength uniform atomic building blocks of a RRC by their nonuniform counterparts. The miniaturization procedure has been realized in three progressive steps: (i) the first layout solution of a miniaturized RRC has been acquired...
-
Estimation of the short-term predictor parameters of speech under noisy conditions
Publication -
Speech formant frequency and pitch estimation using instantaneous complex frequency
PublicationW pracy opisany został algorytm estymacji częstotliwości podstawowej oraz częstotliwości środkowych i pasm formantów mowy z wykorzystaniem zespolonej pulsacji chwilowej. W artykule przedstawiono również wyniki działania algorytmu dla polskich samogłosek.
-
The motion influence on respiration rate estimation from low-resolution thermal sequences during attention focusing tasks
PublicationGlobal aging has led to a growing expectancy for creating home-based platforms for indoor monitoring of elderly people. A motivation is to provide a non-intrusive technique, which does not require special activities of a patient but allows for remote monitoring of elderly people while assisting them with their daily activities. The goal of our study was to evaluate motion performed by a person focused on a specific task and check...
-
Novel structure and EM-driven design of miniaturized microstrip rat-race coupler
PublicationIn this paper, a novel structure and design procedure of a miniaturized microstrip rat-race coupler (RRC) is described. Small size of the RRC is achieved by folding the transmission lines of the conventional circuit into its interior, as well as by implementation of the structure on three layers. The final size of the coupler realized for the operating frequency of 1 GHz is only 220 mm2, which gives over 95% footprint reduction...
-
A compact seven-section rat-race hybrid coupler incorporating pbg cells
PublicationA conventional rat-race coupler has been doubly miniaturized: (i) characteristic impedances and electrical lengths of microstrip sections have been adequately modified as the first step of size reduction and (ii) T-shaped PBG cells have been implemented to diminish strip section length as the second step of circuit rat-race couplerminiaturization. The experimental results show good agreement with theoretical characteristics. Furthermore,...
-
Pitch estimation of narrowband-filtered speech signal using instantaneous complex frequency
PublicationIn this paper we propose a novel method of pitch estimation, based on instantaneous complex frequency (ICF). New iterative algorithm for analysis of ICF of speech signal in presented. Obtained results are compared with commonly used methods to prove its accuracy and connection between ICF and pitch, particularly for narrowband-filtered speech signal.
-
Pitch estimation of narrowband-filtered speech signal using instantaneous complex frequency
PublicationIn this paper we propose a novel method of pitch estimation, based on instantaneous complex frequency (ICF). New iterative algorithm for analysis of ICF of speech signal in presented. Obtained results are compared with commonly used methods to prove its accuracy and connection between ICF and pitch, particularly for narrowband-filtered speech signal.
-
A novel microstrip dual-layer rat-race coupler with compact size and enhanced bandwidth
PublicationMicrowave hybrid couplers are crucial components of mixers, phase shifters, amplifiers and other high-frequency systems. Conventional couplers are characterized by large size which limits their usefulness in modern applications. In this work, a novel compact rat-race coupler with enhanced bandwidth has been proposed. The structure consists of six compact microstrip resonant cells. It is implemented on two separate layers which permits...
-
Novel structure and size-reduction-oriented design of microstrip compact rat-race coupler
PublicationIn this paper, a novel structure of a miniaturized microstrip rat-race coupler has been proposed. Surrogate-based optimization procedures are applied to explicitly reduce the coupler size while maintaining equal power split at the operating frequency of 1 GHz and sufficient bandwidth for return loss and isolation characteristics. The optimization is performed using the objective function with four penalty components. The footprint...
-
On Design Optimization of Miniaturized Microscrip Dual-Band Rat-Race Coupler with Enhanced Bandwidth
PublicationIn the paper, a novel topology of a miniaturized wideband dual-band rat-race coupler has been presented. Small size of the circuit has been obtained by meandering transmission lines of the conventional circuit. At the same time, the number of independent geometry parameters has been increased in order to secure sufficient circuit flexibility in the context of its design optimization for dual-band operation. Optimum dimensions of...
-
Design of a compact planar transmission line for miniaturized rat-race coupler with harmonics suppression
PublicationThis paper presents an elegant yet straightforward design procedure for a compact rat-race coupler (RRC) with an extended harmonic suppression. The coupler’s conventional λ/4 transmission lines (TLs) are replaced by a specialized TL that offers significant size reduction and harmonic elimination capabilities in the proposed approach. The design procedure is verified through the theoretical, circuit, and electromagnetic (EM) analyses,...
-
Stochastic Integration and Long Term Predictor Estimation under Noisy Conditions for Speech Enhancement
Publication -
Mowa nienawiści (hate speech) a odpowiedzialność dostawców usług internetowych w orzecznictwie sądów europejskich
PublicationThe article analyses the phenomenon of hate speech in the Internet contrasted with the problem of responsability of Internet Service Providers for cases of such abuses of freedom of expression. The text provides an analysis of jurisprudence of two European Courts. On the one hand it presents the position of the European Court of Human Rights on the problem of hate speech: its definition and the liability for it as an exception...
-
The instantaneous frequency rate spectogram
PublicationAn accelerogram of the instantaneous phase of signal components referred to as an instantaneous frequency rate spectrogram (IFRS) is presented as a joint time-frequency distribution. The distribution is directly obtained by processing the short-time Fourier transform (STFT) locally. A novel approach to amplitude demodulation based upon the reassignment method is introduced as a useful by-product. Additionally, an estimator of energy...
-
Denitrifcation rate in the mainstream deammonification
PublicationThe conventional processes of biological nitrogen removal based on nitrification and denitrification does not fit properly into the concept of the circular economy. As the alternative one should consider the deammonification process, which is a combination of partial nitrification (nitritation) and Anammox processes. It consists of removing ammonium nitrogen from wastewater under anaerobic conditions by a group of autotrophic microorganisms....
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV) analysis in rats exposed to hypoxia and hyperoxia
Publication -
Estimation of autotrophic maximum specific growth rate constant-experience from the long-term operation of a laboratory-scale Sequencing Batch Reactor System
PublicationW pracy wykorzystano wyniki badań z długookresowej eksploatacji laboratoryjnego reaktora typu SBR do estymacji stałej szybkości przyrostu bakterii nitryfikacyjnych. Badania obejmowały zarówno pomiary empiryczne (doświadczenia przy niskim stosunku substratu do biomasy) oraz symulacje komputerowe. Do symulacji dynamicznych wykorzystano jedną wartość współczynnika = 1,2 1/d, pomimo różnych wartości mierzonych jednostkowych szybkości...
-
Rapid Design Tuning of Miniaturized Rat-Race Couplers Using Regression-Based Equivalent Network Surrogates
PublicationA simple technique for fast design tuning of compact rat-race couplers is presented. Our approach involves equivalent circuit representation, corrected by nonlinear functions of frequency with coefficients extracted through nonlinear regression. At the same time, the tuning process connects two levels of coupler representation: EM simulation of the entire circuit and re-optimization of the coupler building blocks (slow-wave cells...
-
Inverse modeling for fast design optimization of small-size rat-race couplers incorporating compact cells
PublicationIn the paper, a framework for computationally-efficient design optimization of compact rat-race couplers (RRCs) is discussed. A class of hybrid RRCs with variable operating conditions is investigated, whose size reduction is obtained by replacing ordinary transmission lines with compact microstrip resonant cells (CMRCs). Our approach employs a bottom-up design strategy leading to the development of compact RRCs through rapid design...
-
A structure and design optimization of novel compact microscrip dual-band rat-race coupler with enhanced bandwidth
PublicationIn the letter, a topology of a novel compact wideband dual-band rat-race coupler has been presented along with its computationally efficient design optimization procedure. Reduction of the circuit size has been achieved by meandering transmission lines of the conventional circuit. At the same time, the number of independent geometry parameters has been increased so as to secure sufficient flexibility of the circuit, necessary in...
-
Minimum mean square error estimation of speech short-term predictor parameters under noisy conditions
Publication -
Estimation of time-frequency complex phase-based speech attributes using narrow band filter banks
PublicationIn this paper, we present nonlinear estimators of nonstationary and multicomponent signal attributes (parameters, properties) which are instantaneous frequency, spectral (or group) delay, and chirp-rate (also known as instantaneous frequency slope). We estimate all of these distributions in the time-frequency domain using both finite and infinite impulse response (FIR and IIR) narrow band filers for speech analysis. Then, we present...
-
Partitioning total heart rate variability
Publication -
Diverging changes in rat striatal extracellular dopamine and DOPAC levels and in frequency-modulated 50-kHz ultrasonic vocalizations rate during repeated amphetamine treatment
Publication -
Sample Rate Conversion with Fluctuating Resampling Ratio
PublicationIn this paper a sample rate conversion with continuously changing resampling ratio has been presented. The proposed implementation is based on variable fractional delay filter implemented using a Farrow structure. It have been demonstrated that using the proposed approach instantaneous resampling ratio can be freely changed. This allows for simulation of audio recored on magnetic tape with nonuniform velocity as well as removal...
-
Forecasting of the Employment Rate in the EU ICT Field
Publication -
Telemedicine methods for low bit rate communication
PublicationW pracy przedstawiono metody, które mogą być zastosowane w wybranych aspektach telemedycyny przy zredukowanym strumieniu danych. Przedstawiono i omówiono rozwiązania dla telekonsultacji przygotowanych (przygotowane dane, telekonsultacje w czasie rzeczywistym) oraz telekonsultacji w wypadkach nagłych.
-
Sample Rate Conversion with Fluctuating Resampling Ratio
PublicationIn this paper a sample rate conversion with continuouslychanging resampling ratio has been presented. The proposed implementation is based on variable fractional delay filter implemented using a Farrow structure. It have been demonstrated that using the proposed approach instantaneous resampling ratio can be freely changed. This allows for simulation of audio recored on magnetic tape with nonuniform velocity as well as removal...