Filters
total: 18
Search results for: ECG MONITORING, CONTACTLESS, CMRR
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
A New Coupler Concept for Contactless High-Speed Data Transmission Monitoring
PublicationThis paper presents a new concept of a couplerthat can be applied to high-speed data transmission contactlessmeasurements. The proposed approach is dedicated for differentialsignal transmission monitoring in microstrip coupled lineson printed circuit boards (PCBs). The coupler, produced on aseparate PCB, is overlayed on the transmission line with thedifferential signal and delivers decoupled differential signal tothe main measurement...
-
A scale with ECG measurements capability for home cardiac monitoring
PublicationPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
The contactless method of chip-to-chip high-speed data transmission monitoring
PublicationThis paper presents a technique of decoupling differential signals transmitted in a pair of microstrip lines on a printed circuit board (PCB), using dedicated coupler for high speed data transmission monitoring in chip-to-chip interconnections. The coupler used for signal probing is overlayed on the pair of microstrip lines under test, and provides a signal to the next blocks of the measurement system without disturbing transmission...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Assessment of Clinical Usefulness of Resting Electrocardiogram (PH-ECG Score) in Monitoring the Efficacy of Balloon Pulmonary Angioplasty (BPA) in Patients with Chronic Thromboembolic Pulmonary Hypertension (CTEPH)
Publication -
Analysis of positioning error and its impact on high frequency properties of differential signal coupler
PublicationThis paper presents the analysis of the effect of differential signal coupler positioning accuracy on its high frequency performance parameters for contact-less high speed chip-to-chip data transmission on PCB application. Our considerations are continuation of the previous works on differential signal coupler concept, design methodology and analysis for high speed data transmission monitoring. The theoretical analysis of possible...
-
Smart Weighing Scale with Feet-Sampled ECG
PublicationIn a smart home, health and well-being monitoring systems could be embedded in everyday devices providing a pervasive care. A home bathroom scale is an example of such a device, typically used to measure body weight and very often its composition (e.g. body water/fat percentage). In this paper, we analyzed a potential use of the bathroom scale to measure electrocardiogram (ECG) from electrodes located on the scale's tile. In particular...
-
Analysis of Positioning Error and Its Impact on High Frequency Performance Parameters of Differential Signal Coupler of Differential Signal Coupler
PublicationThis paper presents the analysis of the effect of differential signal coupler positioning accuracy on its high frequency performance parameters for contact-less high speed chip-to-chip data transmission on PCB application. Our considerations are continuation of the previous works on differential signal coupler concept, design methodology and analysis for high speed data transmission monitoring presented in [1, 2]. The theoretical...
-
Remote Health Monitoring of Wind Turbines Employing Vibroacoustic Transducers and Autoencoders
PublicationImplementation of remote monitoring technology for real wind turbine structures designed to detect potential sources of failure is described. An innovative multi-axis contactless acoustic sensor measuring acoustic intensity as well as previously known accelerometers were used for this purpose. Signal processing methods were proposed, including feature extraction and data analysis. Two strategies were examined: Mel Frequency Cepstral...
-
Assessment of cardiovascular risk in assisted living
PublicationWady i choroby układu krążenia są jedną z podstawowych przyczyn problemów zdrowotnych oraz przyczyn śmierci. Wczesne ich wykrycie jest szczególnie cenne jako, że może zapobiec przez poważnymi incydentami (np. zawał, udar, itp.). W artykule przedstawiono nasobny system pomiarowy integrujący wiele pomiarów przydatnych do oceny problemów kardiologicznych.Disorders of the heart and blood vessels are the leading cause of health problems...
-
ECG-based prediction of ventricular fibrillation by means of the PCA
PublicationA Sudden Cardiac Death (SCD) is a death resulting from cardiac failure with no significant symptoms earlier than one hour before occurrence. It is the cause of for approximately 400000 deaths per year in United States and millions of deaths worldwide. The proposed system, including two-stage algorithm and wearable diagnostic device allows for SCD risk estimation and continuous monitoring of high risk patients. A single channel...
-
Eulerian motion magnification applied to structural health monitoring of wind turbines
PublicationSeveral types of defects may occur in wind turbines, as physical damage of blades or gearbox malfunction. A wind farm monitoring and damage prediction system is built to observe abnormal vibrations of elements of wind turbine: blades, nacelle, and tower. Contactless methods are developed which do not require turbine stopping. In this work, structural health monitoring of a wind turbine is evaluated using a conversion from the captured...
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Algoritmically improved microwave radar monitors breathing more acurrate than sensorized belt
PublicationThis paper describes a novel way to measure, process, analyze, and compare respiratory signals acquired by two types of devices: a wearable sensorized belt and a microwave radar-based sensor. Both devices provide breathing rate readouts. First, the background research is presented. Then, the underlying principles and working parameters of the microwave radar-based sensor, a contactless device for monitoring breathing, are described....
-
QRS Morphology-Based EDR Signal—Factors Determining its Properties
PublicationRespiration-induced signals contain a clinically significant information. It could be obtained utilizing both direct and indirect methods. ECG-Derived Respiration (EDR) method is the latter one. However, in this case, two approaches could be distinguished. First one is based on determining changes in the morphology of QRS complexes while the second one is based on the Respiratory Sinus Arrhythmia (RSA) mechanism. The former approach...
-
Innovative Implantable Left Ventricular Assist Device—Performance under Various Resistances and Operating Frequency Conditions
PublicationThis paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device pumping helium into a set of intra-cardiac balloons. In this way, the ejection fraction of the left ventricle is increased, and the mitral valve is additionally occluded. What is...