Filters
total: 191
filtered: 154
Search results for: IMPLANTS
-
Degradation of metallic implants
PublicationPresence of metallic implants made of stainless steels, Co and Ti alloys is sometimes followed by some undesired allergic reactions and inflammatory processes and consequently the necessity of reimplantation.
-
The degradation of metal implants
PublicationThe presence of metal implants in the human body causes some dangers, which result from introducing another object into organism. There may occur a biocorrosion, which causes different modifications of implant surface.
-
Mechanical Properties of Implants
PublicationW pracy przedstawiono wyniki identyfikacji ortogonalnego modelu matematycznego czterech typów implantów stosowanych w laparoskopowym leczeniu przepukliny brzusznej.
-
3D Printing of Metallic Implants
PublicationThe fabrication of various elements, solid and open porous structures of stainless steel and Ti alloy is described. The process was started with the design of 3D models in CAD/CAM system. The 3D models were transformed into *.stl files and then the manufacturing process of the real structures by means of the selective laser melting with the SLM Realizer 100 3D printer was made. The paper shows the porous specimens made for possible...
-
Engineering Challenges in the Design of Cochlear Implants
PublicationHearing aids such as cochlear implants have been used by both adults and children for a long time. In addition, cochlear implants are used by patients who have severe hearing loss either by birth or after an accident. This paper aims to investigate the engineering challenges bounding the design of cochlear implants and present its possible solution...
-
The problem of infections associated with implants – an overview
PublicationImplant-associated infections are serious and relatively common complication that leads to implant loss. The purpose of this paper is to gather knowledge about this issue. A literature review of the epidemiology, risk factors and pathogenesis of infections related to implants was carried out. This position collects data on commonly used implants and infections associated with them from various fields of medicine and contains classifications...
-
The mechanisms of degradation of titanium dental implants
PublicationTitanium dental implants show very good properties, unfortunately there are still issues regarding material wear due to corrosion, implant loosening, as well as biological factors—allergic reactions and inflammation leading to rejection of the implanted material. In order to avoid performing reimplantation operations, changes in the chemical composition and/or modifications of the surface layer of the materials are used. This research...
-
Bioactive polyurethanes applied as a surgical implants
PublicationSynthetic materials are applied in many branches of the industry, i.a. in medicine as a casing of apparatus, elements of artificial organs (hearts, blood vessels), catheters, wound healings, intra aortic balloons, mammary implants to mention but a few. Polymeric material used in such applications must be distinguished by a good biocompatybility. Since many years extensive research are employed to develop a new polymers that can...
-
Conducting polymers for biodegradable metallic implants
PublicationNowadays permanent metallic cardiovascular stents are long-term implants. The long-time presence of such an implant in human body can cause overgrowth of tissue within the treated portion of the vessel, blockage of the circulatory system and many other clinical complications, such as thrombosis, prolonged physical irritations or chronic inflammation. Therefore, in recent years, there is an interest to create biodegradable metallic...
-
In vivo degradation of short-term implants
PublicationStan powierzchni wywiera istotny wpływ na właściwości użytkowe implantu. Stawiane wymagania, zależą od funkcji jakie ma spełniać wszczep oraz rodzaju implantowanego materiału. W przypadku implantów krótkotrwałych wymagana jest przede wszystkim odpowiednia odporność korozyjna, nie powinno tworzyć się trwałe połączenie pomiędzy wszczepem a tkanką kostną.Wszystkie biomateriały ulegają degradacji. Ważne jest to, aby produkty tej degradacji...
-
Degradation of metal implants covered with silver
PublicationSilver was known for its antibacterial properties as long ago as in antiquity. The silver ions have ability to join the bacteria surface. Low density of silver ions Ag+ influence the protons through the bacteria surface, which results in total destruction of the cell. Antibacterial activity of silver remains in proportion with the density of silver ions Ag+ in the environment.
-
Microstructural Analysis of Fractured Orthopedic Implants
Publication -
The influence of biological environment on the silver-coated implants
PublicationThis paper deals with implants covered with nanosilver
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublicationCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublicationTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Porous materials used as inserted bone implants
PublicationArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
New techniques assisting cochlear implants fitting.
PublicationW referacie przedstawiono metodę telemetrii odpowiedzi neuronalnej (SoE), którą zastosowano w celu oceny amplitudy sygnału, która będzie wywoływała percepcję słuchową poprzez pobudzenie elektrod implantu ślimakowego. Jest to obiektywna metoda wyznaczania skuteczności systemów implantów ślimakowych.
-
The influence of biological environment on the appearance of silver-coated implants
PublicationDespite antibiotics preventive treatment before and after implantation, risk of infection is real. The infections at the implant surface developein a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with silver layer come into use. The paper presents the research results in biological environment on vein and orthopaedicimplants covered with...
-
Porous biomaterial for orthopaedic implants based on titanium alloy
PublicationTytan i jego stopy są szeroko stosowane jako biomateriały dla zastosowań ortopedycznych. Badania związane z ich najlepszą odpornością na korozję i ścieranie, biozgodnością i bioaktywnością są stale prowadzone. Obecne badania koncentrują się również na projektowaniu i produkcji materiałów porowatych w oparciu o stopy np. Ti-13Nb-13Zr, które mogą być stosowane do wytwarzania implantów. Jedną z najbardziej efektywnych metod wytwarzania...
-
Metal implants in ostheosynthesis - construction solutions, materials and applications
PublicationThe aim of the article is to present two case studies on intramedullary nails. The research included the evaluation of the type of fracture and the analysis of microstructure, chemical composition and hardness of the implant material.
-
Characteristics of orthopaedic implants damage and mechanisms of its initiation
Publication -
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
The allergic and irritating reactions to metallic implants with trauma - orthopaedic patients
PublicationThe article presents the analysis of clinical operation complications after the treatment of long bones by mean of ostheosynthesis with the use of metal implants and endoprothesoplastic of hip joints.
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublicationThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublicationResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublicationThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublicationObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
The bahaviour of selected silver coated body implants in presence of various bacteria
PublicationThe article deals with implants covered with silver nanoparticles and its influence on bacteria adhesion.
-
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublicationCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...
-
Comprehensive Evaluation of the Biological Properties of Surface-Modified Titanium Alloy Implants
PublicationAn increasing interest in the fabrication of implants made of titanium and its alloys results from their capacity to be integrated into the bone system. This integration is facilitated by different modifications of the implant surface. Here, we assessed the bioactivity of amorphous titania nanoporous and nanotubular coatings (TNTs), produced by electrochemical oxidation of Ti6Al4V orthopedic implants’ surface. The chemical composition...
-
Enhancing middle ear implants: Study of biocompatible materials with hydroxyapatite coating
PublicationIn this manuscript, the application of hydroxyapatite coatings to total ossicular reconstruction prostheses (TORPs) using finite element modeling simulations was investigated to enhance the biocompatibility and mechanical performance of these prosthetic devices for middle ear implants. We focused on evaluating biocompatible materials, particularly polyetheretherketone (PEEK) and titanium, by analyzing their mechanical behavior...
-
Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches
PublicationWhile cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical...
-
Nanotubular Oxide Layer Formed on Helix Surfaces of Dental Screw Implants
PublicationSurface modification is used to extend the life of implants. To increase the corrosion resistance and improve the biocompatibility of metal implant materials, oxidation of the Ti-13Nb- 13Zr titanium alloy was used. The samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of...
-
Are Titania Photocatalysts and Titanium Implants Safe? Review on the Toxicity of Titanium Compounds
Publication -
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublicationTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
Electro-optical system for the automated selection of dental implants according to their colour matching
Publication -
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublicationThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study
PublicationPrimary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The aim of this study is to investigate the influence of the cortical and trabecular bone Young's moduli Ec and Et, the interference...
-
Studies on Silver Ions Releasing Processes and Mechanical Properties of Surface-Modified Titanium Alloy Implants
PublicationDispersed silver nanoparticles (AgNPs) on the surface of titanium alloy (Ti6Al4V) and titanium alloy modified by titania nanotube layer (Ti6Al4V/TNT) substrates were produced by the chemical vapor deposition method (CVD) using a novel precursor of the formula [Ag5(O2CC2F5)5(H2O)3]. The structure and volatile properties of this compound were determined using single crystal X-ray diffractometry, variable temperature IR spectrophotometry...
-
Biological effect of hydrothermally synthesized silica nanoparticles within crystalline hydroxyapatite coatings for titanium implants
Publication -
Composites of polylactide and nano-hydroxyapatite created by cryomilling and warm isostatic pressing for bone implants applications
Publication -
Development and biological evaluation of Ti6Al7Nb scaffold implants coated with gentamycin-saturated bacterial cellulose biomaterial
Publication -
In Vitro and Ex Vivo Chemical Stability Studies of Layers on Substrates and Implants Made of Titanium Alloy
Publication -
Rozwój materiałów tytanowych na implanty aloplastyczne = Development of Ti-based materials for alloplastic implants
PublicationThe article is aimed at demonstraiting the previous results and current research work in the area made by Advanced Biomaterials Research Group at the Faculty of Mechanical Engineering. The paper concentrated on the developement of Ti-based biomaterials with improved biocompatibility and bioactivity.
-
The research of glass-ceramics implants used for bone pitches to examine bacteria adhesion occuring in human body
PublicationThe paper deals with the research concerning the bacteria adhesion on bioactive glass - ceramics materials