Search results for: PUMPS
-
Prospects of Decreasing Power Losses in a Hydrostatic Thrust Bearing
PublicationIn numerous machines, axial load is carried by tilting pad thrust bearings known since the beginning of 20th century. These bearings are commonly bath lubricated, which is simple, does not require any additional pumps, and, due to this, such systems are highly reliable. In a contemporary technology, however, minimization of friction losses became an important goal of machinery improvement. Calculations based on elementary rules...
-
Protection System Design of Induction Motor for Industries
PublicationThe fundamental and durable structures of induction motor, as well as their low manufacturing cost, make them popular components in a wide range of current applications. Providing a safety net for employees is a must-have for businesses. This project’s motivation for improvement is to provide industrial motors, lift motors, pumps, and so on with safety. An induction motor’s primary goal is to protect it from problems, such as...
-
Protection System Design of Induction Motor for Industries
PublicationThe fundamental and durable structures of induction motor, as well as their low manufacturing cost, make them popular components in a wide range of current applications. Providing a safety net for employees is a must-have for businesses. This project’s motivation for improvement is to provide industrial motors, lift motors, pumps, and so on with safety. An induction motor’s primary goal is to protect it from problems, such as...
-
Kompensacja skoków ciśnienia w pompie tłoczkowej o zmiennej wydajności z rozrządem krzywkowym
PublicationPrzedmiotem rozprawy doktorskiej jest opis matematyczny, badania i symulacja mechanizmu kompensacji skoków ciśnienia w pompie tłoczkowej z rozrządem krzywkowym typu PWK. W rozprawie przedstawiono istniejące rozwiązania konstrukcyjne pomp tłokowych, kładąc szczególny nacisk na przedstawienie stosowanych w nich mechanizmów rozrządu i kompensacji skoków ciśnienia. Ponadto szczegółowo opisano budowę i zasadę działania pompy PWK będącej...
-
Chemosensitization of multidrug resistant Candida albicans by the oxathiolone fused chalcone derivatives
PublicationThree structurally related oxathiolone fused chalcone derivatives appeared effective chemosensitizers, able to restore in part sensitivity to fluconazole of multidrug-resistant C.albicans strains. Compound 21 effectively chemosensitized cells resistant due to the overexpression of the MDR1 gene, compound 6 reduced resistance of cells overexpressing the ABC-type drug transporters CDR1/CDR2 and derivative 18 partially reversed fluconazole...
-
Wpływ właściwości czynników chłodniczych na straty egzergii w pompie ciepła (Influence of Refrigerants Properties for Exergy Losses in Heat Pump)
PublicationArtykuł poświęcony jest wpływowi występujących w pompie ciepła strat egzergii na jej efektywność energetyczną, a co za tym idzie koszty funkcjonowania instalacji. Autorzy prezentują tu metodologię obliczeniową, która może być zastosowana w procesach projektowania układów cieplno-przepływowych. Obliczenia zostały wykonane na podstawie typowego układu powietrznej pompy ciepła pracującej w klimacie środkowo-europejskim. Ponadto w...
-
STUDY ON THE EFFECTIVENESS OF THE TURBINE CONDENSER AIR EXTRACTION SYSTEM USING HYDRO EJECTORS
PublicationThe aim of the paper is to investigate the effectiveness of the 18K380 steam turbine condenser air extraction system using hydro ejectors. Motivation for the analysis is a need of improvement of the energy conversion ratio of the power plant. To achieve this goal it is necessary to establish efficiency of each subsystem of the energy cycle. The air extraction system is not a highly power consuming system but it has great impact...
-
Marine propeller shaft bearings under low-speed conditions: water vs. oil lubrication
PublicationThe bearings used in shipbuilding, hydropower, and water pumps have undergone a metamorphosis in recent decades. Because of environmental regulations, lubrication with grease or mineral oil is prohibited. Thus, the standard solutions include water-lubricated bearings with polymer bushings or sealed systems lubricated with oil. When properly designed, assembled, and operated, bearings can operate reliably for years. However, specific...
-
APPLICATION OF THE THEORY OF SEMI-MARKOV PROCESSES TO DETERMINE A LIMITING DISTRIBUTION OF THE PROCESS OF CHANGES OF ABILITY AND INABILITY STATES OF FUEL SUPPLY SYSTEMS IN HEAVY FUEL DIESEL ENGINES
PublicationThe paper presents applicability of the theory of semi-Markov processes to determine a limiting distribution of the process of changes of technical states of fuel systems for marine engines running on heavy fuel oils. The proposed study of this process includes the components of such fuel systems like: 1 - injectors, 2 - high pressure hoses, 3 - injection pumps, 4 - low pressure hoses, 5 – fine filters, 6 - coarse filters, 7 – fuel-feed...
-
Multiobjective Water Distribution Systems Control of Pumping Cost, Water Quality, and Storage-Reliability Constraints
PublicationThis work describes a multiobjective model for trading-off pumping cost and water quality for water distribution systems operation. Constraints are imposed on flows and pressures, on periodical tanks operation, and on tanks storage. The methodology links the multiobjective SPEA2 algorithm with EPANET, and is applied on two example applications of increasing complexity, under extended period simulation conditions and variable energy...
-
EXPERIMENTAL RESEARCH ON INFLUENCE OF THE FUEL NOZZLE GEOMETRY ON THE FUEL CONSUMPTION OF THE MARINE 4-STROKE DIESEL ENGINE
PublicationThe article presents experimental research that has been carried out on a marine, 4-stroke, 3-cylinder, turbocharged engine. During testing, the engine operated at a constant rotational speed of 750 rpm and a load from 0 kW to 280 kW. The engine was fuelled by diesel oil of known specification and loaded by electric generator with water resistance. The fuel consumption was measured during the engine operation with fuel nozzles...
-
Pressure drop and heat transfer during boiling and condensation at subcritical region
PublicationMost of the data presented in the literature relate to saturation temperatures in the range - 20°C to 40°C due to the application in refrigeration technology. There is necessity to extend databases to higher values of saturation temperature due to new applications such as Organic Rankine Cycle and high temperature heat pumps. Only few papers contain data for high reduced pressure for low boiling point liquids. This paper focus...
-
Multi-Objective Water Distribution Systems Control of Pumping Cost, Water Quality, and Storage-Reliability Constraints
PublicationThis work describes a multi-objective model for trading-off pumping cost and water quality for water distribution systems operation. Constraints are imposed on flows and pressures, on periodical tanks operation, and on tanks storage. The methodology links the multi-objective SPEA2 algorithm with EPANET, and is applied on two example applications of increasing complexity, under extended period simulation conditions and variable...
-
Greenhouse control system design
PublicationCoraz większa populacja i zmniejszające się tereny uprawne wymusza efektywniejsze metody uprawy roślin. Zaradzić temu mogą układu hydroponiczne, które dzięki rozwojowi techniki są w stanie osiągać znacznie większe oraz bardziej jednorodne plony. Jest to możliwe dzięki zaawansowanym systemom opartym na dokładnych urządzeniach pomiarowych, sterowaniu w zamkniętej pętli oraz mikrokontrolerom umożliwiającym...
-
Simulation of fluid structure interaction in a novel design of high pressure axial piston pump
PublicationA novel type of an axial, piston-driven high pressure hydraulic pump with variable capacity marks a significant improvement in the area of the hydraulic machinery design. Total discharge from hydrostatic forces eliminates a need for a servomechanism, thus simplifying operation, reducing weight and introducing the possibility of the pump displacement control by computer. PWK-type pumps, invented in the Gdansk University of Technology,...
-
Simulation of fluid structure interaction in a novel design of high pressure axial piston hydraulic pump
PublicationA novel type of an axial, piston-driven high pressure hydraulic pump with variable capacity marks a significant improvement in the area of the hydraulic machinery design. Total discharge from hydrostatic forces eliminates a need for a servomechanism, thus simplifying operation, reducing weight and introducing the possibility of the pump displacement control by computer. PWK-type pumps, invented in the Gdansk University of Technology,...
-
‘Acridines’ as New Horizons in Antifungal Treatment
PublicationFrequent fungal infections in immunocompromised patients and mortality due to invasive mycosis are important clinical problems. Opportunistic pathogenic Candida species remain one of the leading causes of systemic mycosis worldwide. The repertoire of antifungal chemotherapeutic agents is very limited. Although new antifungal drugs such as lanosterol 14α-demethylase and β-glucan synthase inhibitors have been introduced into clinical...
-
Experimental Research of an Axial Piston Pump with Displaced Swash Plate Axis of Rotation
PublicationThe article describes the influence of displacement of the swash plate rotation axis on the efficiency of axial piston pumps. The dead space volume was defined as the volume of the working chamber in the extreme position of the piston at the end of the pumping phase and its variability was determined as a function of the position of the axis of rotation of the swash plate and the swing angle of swash plate. The influence of swash...
-
Metal-organic frameworks (MOF) based heat transfer: A comprehensive review
PublicationHigher than a standard level, the humidity provides a suitable environment for the pathogenic microorganisms to grow and increases energy consumption for cooling, increasing greenhouse gas emissions. Desiccant air-conditioning (DAC) is an effective method to reduce humidity and energy simultaneously. Conventional desiccants are not suitable for use as a desiccant in building air conditioners, mainly because of high regeneration...
-
Xanthone synthetic derivatives with high anticandidal activity and positive mycostatic selectivity index values
PublicationWith the current massive increases in drug-resistant microbial infection as well as the significant role of fungal infections in the death toll of COVID-19, discovering new antifungals is extremely important. Natural and synthetic xanthones are promising derivatives, although only few reports have demonstrated their antifungal mechanism of action in detail. Newly synthetized by us xanthone derivative 44 exhibited strong antifungal...
-
Funkcjonowanie zespołów napędu hydraulicznego maszyn w niskich temperaturach otoczenia
PublicationW pracy przedstawiono cztery warianty klasyfikacji rozruchów oziębionego napędu hydraulicznego. Pierwsza sytuacja dotyczy zagadnienia, w którym wszystkie zespoły układu napędowego wraz z olejem mają taką samą niską temperaturę podczas rozruchu. Pozostałe warianty odnoszą się do rozruchu w warunkach szoku termicznego wywołanych zasilaniem ciepłym czynnikiem roboczym oziębionych zespołów hydraulicznych. Rozruch zespołów...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Effect of presence of lifting pocket on the THD performance of a large tilting-pad thrust bearing
PublicationHydrostatic assistance is a commonly used method to improve limited load carrying ability of tiltingpad thrust bearings during transient states of operation of vertical shaft hydro-generators. Despite of special hydraulic equipment (as pumps, valves, etc.), it also requires manufacturing of special recesses/pockets at pad sliding surfaces, into which oil is injected under high pressure. It allows to lift the rotor before start-up...
-
Application of Feed Forward Neural Networks for Modeling of Heat Transfer Coefficient During Flow Condensation for Low and High Values of Saturation Temperatur
PublicationMost of the literature models for condensation heat transfer prediction are based on specific experimental parameters and are not general in nature for applications to fluids and non-experimental thermodynamic conditions. Nearly all correlations are created to predict data in normal HVAC conditions below 40°C. High temperature heat pumps operate at much higher parameters. This paper aims to create a general model for the calculation...
-
The effect of aeration mode (intermittent vs. continuous) on nutrient removal and greenhouse gas emissions in the wastewater treatment plant of Corleone (Italy)
PublicationThe paper reports the results of an experimental study aimed at comparing two configurations of a full-scale wastewater treatment plant (WWTP): conventional activated sludge (CAS) and oxic-settling-anaerobic process (OSA) with intermittent aeration (IA). A comprehensive monitoring campaign was carried out to assess multiple parameters for comparing the two configurations: carbon and nutrient removal, greenhouse gas emissions, respirometric...
-
Charakterystyka eksploatacyjna pomp ciepła zainstalowanych w oczyszczalni ścieków
PublicationW artykule przedstawiono charakterystykę eksploatacyjną sprężarkowych pomp ciepła zainstalowanych w oczyszczalni komunalnej i wykorzystujących ścieki oczyszczone jako dolne źródło ciepła. Zastosowanie ścieków oczyszczonych jest uzasadnione ich dostępnością oraz stosunkowo wysoką temperaturą (10-25°C). Prawidłowa eksploatacja układu wymaga zastosowania pośredniego obiegu parowacza oraz regularnych zabiegów czyszczenia wymiennika...
-
Sustainable energy consumption – Empirical evidence of a household in Poland
PublicationThere is an expected increase in the demand for electricity from households in European countries. The outcome of the growing proportion of renewable energy sources in the energy supply mix should result in improved customer awareness regarding their electricity usage. Additionally, they must assume a more proactive role in overseeing their electricity usage. Innovation and pollution management have become crucial catalysts for...
-
The advanced monitoring as a key factor for appropriate optimization and control of full-scale activated sludge systems – case study Debogorze WWTP.
PublicationComputer simulation has become a helpful tool in wastewater treatment systems performance and effectiveness analysis. Advanced monitoring, by using appropriate software, enables to create a mathematical model of a real wastewater treatment plant (WWTP), run a simulation and subsequently interpret results under various conditions. An operation of WWTP is usually controlled by global parameters such as flow, solids retention time,...
-
PROJEKT ZESPOŁOWY [DK][2023/24]
e-Learning CoursesCCCLECTURE and Classes: Power supply systems for industrial facilities. Devices and main circuits of MV power stations. Short-circuit calculation. Power protection automation. Security classification according to American ANSI standards used in the EU. Microprocessor protection relays. Drive systems for medium power and medium voltage pumps. Roving inverters. PROJECT: Design of a MV switching station for a medium-power pumping...