Search results for: Fabry-Perot interferometer
-
The use of low-coherence interferometer for sugar content determination
PublicationIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublicationIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublicationDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
-
Female Fabry disease patients and X-chromosome inactivation
Publication -
Combined Long-Period Fiber Grating and Microcavity In-Line Mach–Zehnder Interferometer for Refractive Index Measurements with Limited Cross-Sensitivity
PublicationThis work discusses sensing properties of a long-period grating (LPG) and microcavity in-line Mach–Zehnder interferometer (µIMZI) when both are induced in the same single-mode optical fiber. LPGs were either etched or nanocoated with aluminum oxide (Al2O3) to increase its refractive index (RI) sensitivity up to ≈2000 and 9000 nm/RIU, respectively. The µIMZI was machined using a femtosecond laser as a cylindrical cavity (d = 60...
-
Stability of an optical displacement sensor using a two-beam polarization interferometer
PublicationW artykule przedstawiono wyniki pomiarów stabilności wybranej konfiguracji dwuwiązkowego interferometru polaryzacyjnego. Przedyskutowano źródła występującej niestabilności.
-
Laser beam angular stabilization system based on a compact interferometer and a precise double-wedge deflector
Publication -
Application of thin dielectric films in low coherence fiber-optic Fabry-Pérot sensing interferometers: comparative study
Publication -
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Open Research DataPresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Interferometric Sensor of Wavelength Detuning Using a Liquid Crystalline Polymer Waveplate
PublicationOperation of a polarization interferometer for measurement of the wavelength changes of a tunable semiconductor laser was investigated. A lambda/8 waveplate made from liquid crystalline polymer is placed in one of interferometers’ arms in order to generate two output signals in quadrature. Wavelength was measured with resolution of 2 pm in the wavelength range 628–635 nm. Drift of the interferometer, measured in the period of 500...
-
High-Resolution, Broad-Range Detection Setup for Polarimetric Optical Fiber Sensors
PublicationA common-path polarization interferometer using a Wollaston prism and an area detector for the measurement of retardation or optical path difference is presented. Employing a moderate-resolution 1280 by 1024 pixel monochrome camera, it offers a measurement range of approximately 780 radians at 830 nm and 1350 radians at 515 nm while maintaining a high measurement resolution. Retardation introduced by a zero-order waveplate or a...
-
Miniaturowy czujnik temperatury z interferometrem światła białego dla zastosowań biomedycznych.
PublicationW artykule opisano model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry Perota wykorzystującego interferencję światła białego, dla zastosowań biomedycznych.
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublicationOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Sandra Pawłowska
People -
1D portable optical coherence tomography system
Publication—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Compressible gas density measurement by means of Fourier analysis of interferograms
PublicationThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
Quantum mechanical which-way experiment with an internal degree of freedom
PublicationFor a particle travelling through an interferometer, the trade-off between the available which-way information and the interference visibility provides a lucid manifestation of the quantum mechanical wave-particle duality. Here we analyse this relation for a particle possessing an internal degree of freedom such as spin. We quantify the trade-off with a general inequality that paints an unexpectedly intricate picture of wave-particle...
-
The role of low-energy electrons in the charging process of LISA test masses
PublicationThe estimate of the total electron yield is fundamental for our understanding of the test-mass charging associated with cosmic rays in the Laser Interferometer Space Antenna (LISA) Pathfinder mission and in the forthcoming gravitational wave observatory LISA. To unveil the role of low energy electrons in this process owing to galactic and solar energetic particle events, in this work we study the interaction of keV and sub-keV...
-
Human memory enhancement through electrical stimulation in the temporal cortex
PublicationDirect electrical stimulation of the human brain can elicit sensory and motor perceptions as well as recall of memories. Stimulating higher order association areas of the lateral temporal cortex in particular was reported to activate visual and auditory memory representations of past experiences (Penfield and Perot, 1963). We hypothesized that this effect could be used to modulate memory processing. Recent attempts at memory enhancement...
-
Global Complex Roots and Poles Finding Algorithm in C × R Domain
PublicationAn algorithm to find the roots and poles of a complex function depending on two arguments (one complex and one real) is proposed. Such problems are common in many fields of science for instance in electromagnetism, acoustics, stability analyses, spectroscopy, optics, and elementary particle physics. The proposed technique belongs to the class of global algorithms, gives a full picture of solutions in a fixed region ⊂ C × R and...
-
Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor
PublicationAccurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublicationReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublicationFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Optical fiber aptasensor for label-free bacteria detection in small volumes
PublicationHighly sensitive devices for fast bacteria detection are sought to be developed with the task of quantifying the worldwide problem of pathogenic bacteria and thus helping to take control over spreading bacterial infections. This work concerns a sensing solution based on microcavity in-line Mach-Zehnder interferometer (μIMZI) induced in an optical fiber. Such a device exhibits ultrahigh sensitivity to refractive index changes...
-
Optical profilometer
PublicationThe profilometry plays a huge role in the most fields of science and technology. It allows to measure the profile of the surface with high-resolution. This technique is used in the fields like optic, electronic, medicine, automotive, and much more. The aim of the current work was to design and build optical profilometer based on the interference phenomena. The developed device has been working with He-Ne laser (632.8 nm). The optical...
-
Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor
PublicationRolling circle amplification (RCA) of DNA can be considered as a great alternative to the gold standard polymerase chain reaction (PCR), especially during this pandemic period, where rapid, sensitive, and reliable test results for hundreds of thousands of samples are required daily. This work presents the first research to date on direct, real-time and label-free isothermal DNA amplification monitoring using a microcavity in-line...