Filters
total: 162
Search results for: GLUCOSE
-
Noninvasive glucose sensing in scattering media using OCT, PAS, and TOF techniques.
PublicationW pracy przedstawiono możliwości wykorzystania optycznej tomografii koherencyjnej (OCT), spektroskopii fotoakustycznej (PAS)i spektroskopii czasu przelotu (TOF) w pomiarach glukozy w ośrodku silnie rozpraszającym. Równolegle opracowano modele propagacji światła w tych ośrodkach wykorzystując metodę Monte Carlo. W pomiarach wykorzystano ''Intralipid'' jako fantom tkanki. W dalszych badaniach wykorzystano mięso wieprzowe i dokonano...
-
Glucose metabolism disorders in patients with non-functioning adrenal adenomas — single-centre experience
PublicationIntroduction: The presence of glucose metabolism disorders and their possible correlation with degree of cortisol secretion were evaluated in patients with non-functioning adrenal incidentalomas (NFAIs). Material and methods: The study group consisted of 131 patients with hormonally inactive adrenal incidentalomas....
-
Laser-assisted approach for improved performance of Au-Ti based glucose sensing electrodes
PublicationThis paper focuses on the synthesis route and electrochemical properties of electrocatalytic material based on gold nanoparticles (NPs) embedded in a structured titanium template obtained via optimized anodization, chemical etching and laser processing. SEM inspection reveals the presence of Au NPs (60–90 nm in diameter) sited in the titanium foil cavities. Performed electrochemical measurements enable nomination of the set of working...
-
Non-enzymatic flexible glucose sensing platform based on nanostructured TiO2–Au composite
PublicationAll over the world the number of people suffering from diabetes and related complications is drastically growing. Therefore, the need for accurate, reliable and stable sensor for monitoring of glucose in human body fluids is becoming highly desirable. In this work we show that material composed of gold layers deposited onto TiO2 nanotubes (NTs) formed onto the flexible Ti foil exhibits great response toward glucose oxidation and...
-
Decolorisation of Methylene Blue with Sodium Persulfate Activated with Visible Light in the Presence of Glucose and Sucrose
PublicationThe paper presents the results of research on the methylene blue (MB) degradation with sodium persulfate (PDS) activated with visible light (Vis) in the presence of glucose and sucrose. The following test were examined: absence and presence of sugars in concentrations of 50–300 mM, presence and absence of Vis radiation, pH of the model solution (6.0–12.0), identification of free radicals, kinetics of the pseudo-first-order reaction....
-
Bacterial strains colonizing the sensor electrodes of a continuous glucose monitoring system in children with diabetes
Publication -
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublicationPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Persulfates to degrade a mixture of dyes (rhodamine B, methylene blue) in the presence of glucose and visible light
PublicationA treatment process utilizing visible-light-activated (Vis) persulfates (PS) in the presence of an organic promoter (glucose) was developed for the simultaneous decolorization of a rhodamine B (RhB) and methylene blue (MB) mixture. Various doses of glucose, PS concentrations, pH values, initial dye concentrations and process time were tested to find out the most appropriate parameters for degrading the RhB/MB mixture in the...
-
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublicationThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Tetrahedrally modified MnMe0.1Co1.9O4 (Me = Zn, Mg, Li) spinels for non-enzymatic glucose sensing
PublicationIn this work, tetrahedrally modified MnMe0.1Co1.9O4 (Me = Zn, Mg, Li) spinels were prepared via the sol–gel synthesis method with subsequent ball-milling fragmentation. The prepared samples were evaluated as glucose–sensing catalyst. The reference MnCo2O4 spinel exhibited a sensitivity of 49 µA mM−1 cm−2 and a nonlinearity error of 5.2% in the response range from 0.02 to 1 mM. The partial substitution of cobalt in the reference...
-
Boronate-appended polymers with diol-functionalized ferrocene: an effective and selective method for voltammetric glucose sensing
Publication -
Development of New UV–vis Spectroscopic Microwave-Assisted Method for Determination of Glucose in Pharmaceutical Samples
Publication -
Nano-particulate Structures with Glucose-Derived Char and Compacted Fumed Silica in Gaseous and Aqueous Media
Publication -
Measurements of glucose content in scattering media with time-of-flight technique: comparison with Monte Carlo simulations.
PublicationZbadano możliwości pomiaru koncentracji glukozy w materiale silnie rozpraszającym światło z wykorzystaniem techniki czasu przelotu. Badania przeprowadzono wykorzystując ''Intralipid'' będącym fantomem tkanki. Stężenie glukozy wynosiło 100, 200, 300, 500, 1000, 2000,4000 lub 8000 mg/dl. Wyniki pomiarów porównano z wynikami uzyskanymi na drodze modelowania matematycznego.
-
Glucose oxidase as an important yet overlooked factor determiningthe antibacterial activity of bee pollen and bee bread
PublicationBee pollen (BP) and bee bread (BB) have attracted great attention due to their biological activities including antibacterial activity. However, the mechanism of antibacterial activity is largely unknown. Therefore, we aimed to characterise the antibacterial effect of BP and BB aqueous extracts against bacterial pathogens (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis and Enterococcus faecalis)...
-
Ordered titanium templates functionalized by gold films for biosensing applications – Towards non-enzymatic glucose detection
PublicationRecently, metal nanostructures evoke much interest due to application potential in highly sensitive detectors in biochemistry and medical diagnostics. In this work we report on preparation and characteristics of thin (1–100 nm) Au films deposited onto highly ordered structured titanium templates for SERS (Surface Enhanced Raman Spectroscopy) and electrochemical sensing. The Ti templates are formed by selective removal of TiO2 nanotubes...
-
Exploring multi-step glucose oxidation kinetics at GOx-functionalized nanotextured gold surfaces with differential impedimetric technique
PublicationFor a few past years, we can observe the enormous growth of investigations related to ultrasensitive electrochemical sensors capable of reliable determination of important body parameters and analytes. Utilized procedures rely on standard electrochemical methods, demanding electrode polarization, and information about the initial characteristics of the working electrode. More and more complex electrode materials are characterized...
-
Studies in Carbohydrate Based Glues and Thickeners for Foodstuffs. Part I: Glucose - Sucrose - Apple Pectin Ternary System
Publication -
Reduced graphene oxide doping with nanometer-sized ferrocene moieties – New active material for glucose redox sensors
Publication -
Molecular modelling of transition state analogue inhibitors of glucosamine-6-P synthase and glucose-6-P isomerase.
PublicationStruktura kompleksu 2-amino-2-deoksy-D-glucitolo-6-P (ADGP) z centrum aktywnym syntazy GlcN-6-P z E. coli została wykorzystAna jako punkt wyjścia do modelowania molekularnego analogów ADGP. Używając programu GROMOS96 wygenerowano konformacje analogów o najniższych energiach wewnętrznych, które następnie ''dokowano'' w centrum aktywnym enzymu. Dokonano syntezy wybranych związków i określono parametry kinetyczne i termodynamiczne...